Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -35,7 +35,7 @@ 35 35 In this section: 36 36 37 37 * Enable – a flag to enable communication using the protocol; 38 -* CAN port – port which is used to communicate with the charger:38 +* CAN port – port which is used to communicate with the vehicle: 39 39 ** CAN1 (ext); 40 40 ** CAN2 (int); 41 41 * BMS message ID – an identifier of the first message of the device in the J1939 network; ... ... @@ -50,7 +50,7 @@ 50 50 In this section: 51 51 52 52 * Enable – a flag to enable communication with the Evocargo vehicle; 53 -* CAN port – port which is used to communicate with the charger:53 +* CAN port – port which is used to communicate with the vehicle: 54 54 ** CAN1 (ext); 55 55 ** CAN2 (int); 56 56 * Minimum voltage – minimum battery voltage, V; ... ... @@ -60,4 +60,74 @@ 60 60 61 61 To change communication parameters with an insulation monitoring device BMS IMD, select the "External equipment → BMD IMD " section: 62 62 63 -[[image:1739294477662-343.png]] 63 +[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]]In this section: 64 + 65 +* Enable – a flag to enable communication with the IMD; 66 +* CAN port – port which is used to communicate with the IMD: 67 +** CAN1 (ext); 68 +** CAN2 (int); 69 +* Node ID – a CANopen address of the BMS IMD device; 70 +* Configure IMD – a flag to override the IMD warning and alarm settings; 71 +* Allow work if battery modules are joined – a flag to allow the BMS IMD to work only if battery modules are joined; 72 +* Alarm threshold – a threshold resistance value to set insulation alarm, Ohm; 73 +* Warning threshold – a threshold resistance value to set insulation warning, Ohm. 74 + 75 +=== Unibat vehicle === 76 + 77 +To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 78 + 79 +[[image:1739294567774-840.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="600"]]In this section: 80 + 81 +* Enable – a flag to enable communication with the vehicle; 82 +* CAN port – port which is used to communicate with the vehicle; 83 +* Use CRC – a flag to enable checking the checksum of the control message; 84 +* Use DTC – a flag to enable transmit of error codes on battery failures; 85 +* Use additional current sensors to determine error – a flag to use measuring of second and third current sensor to determine errors in battery work; 86 +* Number of modules – total number of battery modules; 87 +* Receive timeout – a timeout for receiving packets from the vehicle (if there is no messages during that time, an error generates), millisecond; 88 +* HVIL delay – a delay before generating a signal of high-voltage interrupt loop breakage, millisecond; 89 +* Nominal voltage, V; 90 +* Maximum charge voltage, V; 91 +* Lower voltage limit, V; 92 +* Upper voltage limit, V; 93 +* Lower temperature limit, °C; 94 +* Upper temperature limit, °C; 95 +* Lower SOC limit, %; 96 +* Upper SOC limit, %; 97 +* Lower cell voltage limit, V; 98 +* Upper cell voltage limit, V; 99 +* Nominal capacity – nominal battery capacity, Wh; 100 +* Current threshold for contactor opening – a current value for safe contactor opening, A; 101 +* Waiting time until the current drops below the threshold – a waiting time for current to drop below estimated value before safe contactor opening, millisecond; 102 +* Control ventilation fans – a flag to send command messages to control battery ventilation fans; 103 +* Version: Manufacturer; 104 +* Version: Hardware ID; 105 +* Version: Software ID; 106 +* Version: Confoguration; 107 +* Version: Serial Number; 108 +* Version: Production date; 109 +* Errors 1, 2 for emergency shutdown – a bitfield with errors to emergency shutdown the vehicle. 110 + 111 +=== ATIB charger === 112 + 113 +To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → ATIB charger" section: 114 +[[image:1739294769684-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="600"]] 115 + 116 +In this section: 117 + 118 +* Enable – a flag to enable communication with the charger; 119 +* CAN port – port which is used to communicate with the charger: 120 +** CAN1 (ext); 121 +** CAN2 (int); 122 +* Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 123 +* Output period - a period of sending commands to the charger, millisecond; 124 +* Charging voltage – maximum charging voltage, V; 125 +* Charging current – maximum charging current, A; 126 +* Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 127 + 128 +(% class="box infomessage" %) 129 +((( 130 +After changing the settings, restart the BMS Main 3X device. 131 +))) 132 + 133 +
- 1739294769684-405.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.5 KB - Content