Changes for page 3.5 External equipment

Last modified by Admin on 2025/05/30 16:50

From version 7.1
edited by Admin
on 2025/02/11 17:22
Change comment: Uploaded new attachment "1739294567774-840.png", version {1}
To version 7.2
edited by Admin
on 2025/02/11 17:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -35,7 +35,7 @@
35 35  In this section:
36 36  
37 37  * Enable – a flag to enable communication using the protocol;
38 -* CAN port – port which is used to communicate with the charger:
38 +* CAN port – port which is used to communicate with the vehicle:
39 39  ** CAN1 (ext);
40 40  ** CAN2 (int);
41 41  * BMS message ID – an identifier of the first message of the device in the J1939 network;
... ... @@ -50,7 +50,7 @@
50 50  In this section:
51 51  
52 52  * Enable – a flag to enable communication with the Evocargo vehicle;
53 -* CAN port – port which is used to communicate with the charger:
53 +* CAN port – port which is used to communicate with the vehicle:
54 54  ** CAN1 (ext);
55 55  ** CAN2 (int);
56 56  * Minimum voltage – minimum battery voltage, V;
... ... @@ -60,4 +60,22 @@
60 60  
61 61  To change communication parameters with an insulation monitoring device BMS IMD, select the "External equipment → BMD IMD " section:
62 62  
63 -[[image:1739294477662-343.png]]
63 +[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]]
64 +
65 +In this section:
66 +
67 +* Enable – a flag to enable communication with the IMD;
68 +* CAN port – port which is used to communicate with the IMD:
69 +** CAN1 (ext);
70 +** CAN2 (int);
71 +* Node ID – a CANopen address of the BMS IMD device;
72 +* Configure IMD – a flag to override the IMD warning and alarm settings;
73 +* Allow work if battery modules are joined – a flag to allow the BMS IMD to work only if battery modules are joined;
74 +* Alarm threshold – a threshold resistance value to set insulation alarm, Ohm;
75 +* Warning threshold – a threshold resistance value to set insulation warning, Ohm.
76 +
77 +=== Unibat vehicle ===
78 +
79 +To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section:
80 +