Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,7 +76,7 @@ 76 76 77 77 To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 78 78 79 -[[image:17 48623056947-344.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="347" width="600"]]79 +[[image:1739970298499-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="302" width="600"]] 80 80 81 81 In this section: 82 82 ... ... @@ -87,9 +87,7 @@ 87 87 * Use CRC – a flag to enable checking the checksum of the control message; 88 88 * Use DTC – a flag to enable transmit of error codes on battery failures; 89 89 * Use additional current sensors to determine error – a flag to use measuring of second and third current sensor to determine errors in battery work; 90 -* Use continuous charge current limit – a flag to use continuous charge current limit; 91 91 * Invert discharge current limit; 92 -* Disable insulation measurement; 93 93 * Number of modules – total number of battery modules; 94 94 * Receive timeout – a timeout for receiving packets from the vehicle (if there is no messages during that time, an error generates), millisecond; 95 95 * HVIL delay – a delay before generating a signal of high-voltage interrupt loop breakage, millisecond; ... ... @@ -106,15 +106,11 @@ 106 106 * Nominal capacity – nominal battery capacity, Wh; 107 107 * Current threshold for contactor opening – a current value for safe contactor opening, A; 108 108 * Waiting time until the current drops below the threshold – a waiting time for current to drop below estimated value before safe contactor opening, millisecond; 109 -* Bus voltage threshold for contactor opening – a voltage value for safe contactor opening, V; 110 -* Waiting time until the voltage drops below the threshold – a waiting time for voltage to drop below estimated value before safe contactor opening, millisecond; 111 -* Insulation measurement period; 112 -* Waiting time for assembling minimum number of modules; 113 113 * Control ventilation fans – a flag to send command messages to control battery ventilation fans; 114 114 * Version: Manufacturer; 115 115 * Version: Hardware ID; 116 116 * Version: Software ID; 117 -* Version: Conf iguration;111 +* Version: Confoguration; 118 118 * Version: Serial Number; 119 119 * Version: Production date; 120 120 * Errors 1, 2 for emergency shutdown – a bitfield with errors to emergency shutdown the vehicle. ... ... @@ -133,6 +133,7 @@ 133 133 * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 134 134 * Output period - a period of sending commands to the charger, millisecond; 135 135 * Charging voltage – maximum charging voltage, V; 130 +* Charging current – maximum charging current, A; 136 136 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 137 137 138 138 (% class="box infomessage" %)
- 1748623056947-344.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -91.2 KB - Content