... ... @@ -76,7 +76,7 @@
76 76  
77 77  To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section:
78 78  
79 -[[image:1748623056947-344.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="347" width="600"]]
79 +[[image:1739970298499-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="302" width="600"]]
80 80  
81 81  In this section:
82 82  
... ... @@ -87,9 +87,7 @@
87 87  * Use CRC – a flag to enable checking the checksum of the control message;
88 88  * Use DTC – a flag to enable transmit of error codes on battery failures;
89 89  * Use additional current sensors to determine error – a flag to use measuring of second and third current sensor to determine errors in battery work;
90 -* Use continuous charge current limit – a flag to use continuous charge current limit;
91 91  * Invert discharge current limit;
92 -* Disable insulation measurement;
93 93  * Number of modules – total number of battery modules;
94 94  * Receive timeout – a timeout for receiving packets from the vehicle (if there is no messages during that time, an error generates), millisecond;
95 95  * HVIL delay – a delay before generating a signal of high-voltage interrupt loop breakage, millisecond;
... ... @@ -106,12 +106,11 @@
106 106  * Nominal capacity – nominal battery capacity, Wh;
107 107  * Current threshold for contactor opening – a current value for safe contactor opening, A;
108 108  * Waiting time until the current drops below the threshold – a waiting time for current to drop below estimated value before safe contactor opening, millisecond;
109 -* Bus
110 110  * Control ventilation fans – a flag to send command messages to control battery ventilation fans;
111 111  * Version: Manufacturer;
112 112  * Version: Hardware ID;
113 113  * Version: Software ID;
114 -* Version: Configuration;
111 +* Version: Confoguration;
115 115  * Version: Serial Number;
116 116  * Version: Production date;
117 117  * Errors 1, 2 for emergency shutdown – a bitfield with errors to emergency shutdown the vehicle.
... ... @@ -130,6 +130,7 @@
130 130  * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond;
131 131  * Output period - a period of sending commands to the charger, millisecond;
132 132  * Charging voltage – maximum charging voltage, V;
130 +* Charging current – maximum charging current, A;
133 133  * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.