Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,7 +76,7 @@ 76 76 77 77 To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 78 78 79 -[[image:17 48623056947-344.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="347" width="600"]]79 +[[image:1739970298499-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="302" width="600"]] 80 80 81 81 In this section: 82 82 ... ... @@ -87,9 +87,7 @@ 87 87 * Use CRC – a flag to enable checking the checksum of the control message; 88 88 * Use DTC – a flag to enable transmit of error codes on battery failures; 89 89 * Use additional current sensors to determine error – a flag to use measuring of second and third current sensor to determine errors in battery work; 90 -* Use continuous charge current limit – a flag to use continuous charge current limit; 91 91 * Invert discharge current limit; 92 -* Disable 93 93 * Number of modules – total number of battery modules; 94 94 * Receive timeout – a timeout for receiving packets from the vehicle (if there is no messages during that time, an error generates), millisecond; 95 95 * HVIL delay – a delay before generating a signal of high-voltage interrupt loop breakage, millisecond; ... ... @@ -110,7 +110,7 @@ 110 110 * Version: Manufacturer; 111 111 * Version: Hardware ID; 112 112 * Version: Software ID; 113 -* Version: Conf iguration;111 +* Version: Confoguration; 114 114 * Version: Serial Number; 115 115 * Version: Production date; 116 116 * Errors 1, 2 for emergency shutdown – a bitfield with errors to emergency shutdown the vehicle. ... ... @@ -129,6 +129,7 @@ 129 129 * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 130 130 * Output period - a period of sending commands to the charger, millisecond; 131 131 * Charging voltage – maximum charging voltage, V; 130 +* Charging current – maximum charging current, A; 132 132 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 133 133 134 134 (% class="box infomessage" %)
- 1748623056947-344.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -91.2 KB - Content