Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,7 +76,7 @@ 76 76 77 77 To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 78 78 79 -[[image:173 9970298499-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="302" width="600"]]79 +[[image:1748623056947-344.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="347" width="600"]] 80 80 81 81 In this section: 82 82 ... ... @@ -87,7 +87,9 @@ 87 87 * Use CRC – a flag to enable checking the checksum of the control message; 88 88 * Use DTC – a flag to enable transmit of error codes on battery failures; 89 89 * Use additional current sensors to determine error – a flag to use measuring of second and third current sensor to determine errors in battery work; 90 +* Use continuous charge current limit – a flag to use continuous charge current limit; 90 90 * Invert discharge current limit; 92 +* Disable 91 91 * Number of modules – total number of battery modules; 92 92 * Receive timeout – a timeout for receiving packets from the vehicle (if there is no messages during that time, an error generates), millisecond; 93 93 * HVIL delay – a delay before generating a signal of high-voltage interrupt loop breakage, millisecond;
- 1748623056947-344.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.2 KB - Content