Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -35,7 +35,7 @@ 35 35 In this section: 36 36 37 37 * Enable – a flag to enable communication using the protocol; 38 -* CAN port – port which is used to communicate with the vehicle:38 +* CAN port – port which is used to communicate with the charger: 39 39 ** CAN1 (ext); 40 40 ** CAN2 (int); 41 41 * BMS message ID – an identifier of the first message of the device in the J1939 network; ... ... @@ -50,7 +50,7 @@ 50 50 In this section: 51 51 52 52 * Enable – a flag to enable communication with the Evocargo vehicle; 53 -* CAN port – port which is used to communicate with the vehicle:53 +* CAN port – port which is used to communicate with the charger: 54 54 ** CAN1 (ext); 55 55 ** CAN2 (int); 56 56 * Minimum voltage – minimum battery voltage, V; ... ... @@ -60,79 +60,4 @@ 60 60 61 61 To change communication parameters with an insulation monitoring device BMS IMD, select the "External equipment → BMD IMD " section: 62 62 63 -[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]]In this section: 64 - 65 -* Enable – a flag to enable communication with the IMD; 66 -* CAN port – port which is used to communicate with the IMD: 67 -** CAN1 (ext); 68 -** CAN2 (int); 69 -* Node ID – a CANopen address of the BMS IMD device; 70 -* Configure IMD – a flag to override the IMD warning and alarm settings; 71 -* Allow work if battery modules are joined – a flag to allow the BMS IMD to work only if battery modules are joined; 72 -* Alarm threshold – a threshold resistance value to set insulation alarm, Ohm; 73 -* Warning threshold – a threshold resistance value to set insulation warning, Ohm. 74 - 75 -=== Unibat vehicle === 76 - 77 -To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 78 - 79 -[[image:1739970298499-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="302" width="600"]] 80 - 81 -In this section: 82 - 83 -* Enable – a flag to enable communication with the vehicle; 84 -* CAN port – port which is used to communicate with the vehicle; 85 -* BMS address; 86 -* VCU address; 87 -* Use CRC – a flag to enable checking the checksum of the control message; 88 -* Use DTC – a flag to enable transmit of error codes on battery failures; 89 -* Use additional current sensors to determine error – a flag to use measuring of second and third current sensor to determine errors in battery work; 90 -* Invert discharge current limit; 91 -* Number of modules – total number of battery modules; 92 -* Receive timeout – a timeout for receiving packets from the vehicle (if there is no messages during that time, an error generates), millisecond; 93 -* HVIL delay – a delay before generating a signal of high-voltage interrupt loop breakage, millisecond; 94 -* Nominal voltage, V; 95 -* Maximum charge voltage, V; 96 -* Lower voltage limit, V; 97 -* Upper voltage limit, V; 98 -* Lower temperature limit, °C; 99 -* Upper temperature limit, °C; 100 -* Lower SOC limit, %; 101 -* Upper SOC limit, %; 102 -* Lower cell voltage limit, V; 103 -* Upper cell voltage limit, V; 104 -* Nominal capacity – nominal battery capacity, Wh; 105 -* Current threshold for contactor opening – a current value for safe contactor opening, A; 106 -* Waiting time until the current drops below the threshold – a waiting time for current to drop below estimated value before safe contactor opening, millisecond; 107 -* Control ventilation fans – a flag to send command messages to control battery ventilation fans; 108 -* Version: Manufacturer; 109 -* Version: Hardware ID; 110 -* Version: Software ID; 111 -* Version: Confoguration; 112 -* Version: Serial Number; 113 -* Version: Production date; 114 -* Errors 1, 2 for emergency shutdown – a bitfield with errors to emergency shutdown the vehicle. 115 - 116 -=== ATIB charger === 117 - 118 -To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → ATIB charger" section: 119 -[[image:1739294769684-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="600"]] 120 - 121 -In this section: 122 - 123 -* Enable – a flag to enable communication with the charger; 124 -* CAN port – port which is used to communicate with the charger: 125 -** CAN1 (ext); 126 -** CAN2 (int); 127 -* Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 128 -* Output period - a period of sending commands to the charger, millisecond; 129 -* Charging voltage – maximum charging voltage, V; 130 -* Charging current – maximum charging current, A; 131 -* Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 132 - 133 -(% class="box infomessage" %) 134 -((( 135 -After changing the settings, restart the BMS Main 3X device. 136 -))) 137 - 138 - 63 +[[image:1739294477662-343.png]]
- 1739294769684-405.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.5 KB - Content
- 1739970298499-463.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -85.1 KB - Content