Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,7 +76,7 @@ 76 76 77 77 To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 78 78 79 -[[image:173 9970298499-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="302" width="600"]]79 +[[image:1748623056947-344.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="347" width="600"]] 80 80 81 81 In this section: 82 82 ... ... @@ -87,7 +87,9 @@ 87 87 * Use CRC – a flag to enable checking the checksum of the control message; 88 88 * Use DTC – a flag to enable transmit of error codes on battery failures; 89 89 * Use additional current sensors to determine error – a flag to use measuring of second and third current sensor to determine errors in battery work; 90 +* Use continuous charge current limit – a flag to use continuous charge current limit; 90 90 * Invert discharge current limit; 92 +* Disable 91 91 * Number of modules – total number of battery modules; 92 92 * Receive timeout – a timeout for receiving packets from the vehicle (if there is no messages during that time, an error generates), millisecond; 93 93 * HVIL delay – a delay before generating a signal of high-voltage interrupt loop breakage, millisecond; ... ... @@ -108,7 +108,7 @@ 108 108 * Version: Manufacturer; 109 109 * Version: Hardware ID; 110 110 * Version: Software ID; 111 -* Version: Conf oguration;113 +* Version: Configuration; 112 112 * Version: Serial Number; 113 113 * Version: Production date; 114 114 * Errors 1, 2 for emergency shutdown – a bitfield with errors to emergency shutdown the vehicle. ... ... @@ -127,7 +127,6 @@ 127 127 * Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 128 128 * Output period - a period of sending commands to the charger, millisecond; 129 129 * Charging voltage – maximum charging voltage, V; 130 -* Charging current – maximum charging current, A; 131 131 * Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 132 132 133 133 (% class="box infomessage" %)
- 1748623056947-344.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.2 KB - Content