Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -60,8 +60,10 @@ 60 60 61 61 To change communication parameters with an insulation monitoring device BMS IMD, select the "External equipment → BMD IMD " section: 62 62 63 -[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]] In this section:63 +[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]] 64 64 65 +In this section: 66 + 65 65 * Enable – a flag to enable communication with the IMD; 66 66 * CAN port – port which is used to communicate with the IMD: 67 67 ** CAN1 (ext); ... ... @@ -72,11 +72,11 @@ 72 72 * Alarm threshold – a threshold resistance value to set insulation alarm, Ohm; 73 73 * Warning threshold – a threshold resistance value to set insulation warning, Ohm. 74 74 75 -=== Unibat vehicle === 77 +=== Unibat vehicle === 76 76 77 77 To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 78 78 79 -[[image:1739 970298499-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="302" width="600"]]81 +[[image:1739294567774-840.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="600"]] 80 80 81 81 In this section: 82 82 ... ... @@ -113,23 +113,8 @@ 113 113 === ATIB charger === 114 114 115 115 To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → ATIB charger" section: 116 -[[image:1739294769684-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="600"]] 117 117 118 - Inthissection:119 + [[image:1739294769684-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="600"]] 119 119 120 -* Enable – a flag to enable communication with the charger; 121 -* CAN port – port which is used to communicate with the charger: 122 -** CAN1 (ext); 123 -** CAN2 (int); 124 -* Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 125 -* Output period - a period of sending commands to the charger, millisecond; 126 -* Charging voltage – maximum charging voltage, V; 127 -* Charging current – maximum charging current, A; 128 -* Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 129 129 130 -(% class="box infomessage" %) 131 -((( 132 -After changing the settings, restart the BMS Main 3X device. 133 -))) 134 - 135 135
- 1739970298499-463.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -85.1 KB - Content