Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -60,8 +60,10 @@ 60 60 61 61 To change communication parameters with an insulation monitoring device BMS IMD, select the "External equipment → BMD IMD " section: 62 62 63 -[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]] In this section:63 +[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]] 64 64 65 +In this section: 66 + 65 65 * Enable – a flag to enable communication with the IMD; 66 66 * CAN port – port which is used to communicate with the IMD: 67 67 ** CAN1 (ext); ... ... @@ -72,64 +72,8 @@ 72 72 * Alarm threshold – a threshold resistance value to set insulation alarm, Ohm; 73 73 * Warning threshold – a threshold resistance value to set insulation warning, Ohm. 74 74 75 -=== Unibat vehicle === 77 +=== Unibat vehicle === 76 76 77 77 To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 78 78 79 -[[image:1739970298499-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="302" width="600"]] 80 - 81 -In this section: 82 - 83 -* Enable – a flag to enable communication with the vehicle; 84 -* CAN port – port which is used to communicate with the vehicle; 85 -* Use CRC – a flag to enable checking the checksum of the control message; 86 -* Use DTC – a flag to enable transmit of error codes on battery failures; 87 -* Use additional current sensors to determine error – a flag to use measuring of second and third current sensor to determine errors in battery work; 88 -* Number of modules – total number of battery modules; 89 -* Receive timeout – a timeout for receiving packets from the vehicle (if there is no messages during that time, an error generates), millisecond; 90 -* HVIL delay – a delay before generating a signal of high-voltage interrupt loop breakage, millisecond; 91 -* Nominal voltage, V; 92 -* Maximum charge voltage, V; 93 -* Lower voltage limit, V; 94 -* Upper voltage limit, V; 95 -* Lower temperature limit, °C; 96 -* Upper temperature limit, °C; 97 -* Lower SOC limit, %; 98 -* Upper SOC limit, %; 99 -* Lower cell voltage limit, V; 100 -* Upper cell voltage limit, V; 101 -* Nominal capacity – nominal battery capacity, Wh; 102 -* Current threshold for contactor opening – a current value for safe contactor opening, A; 103 -* Waiting time until the current drops below the threshold – a waiting time for current to drop below estimated value before safe contactor opening, millisecond; 104 -* Control ventilation fans – a flag to send command messages to control battery ventilation fans; 105 -* Version: Manufacturer; 106 -* Version: Hardware ID; 107 -* Version: Software ID; 108 -* Version: Confoguration; 109 -* Version: Serial Number; 110 -* Version: Production date; 111 -* Errors 1, 2 for emergency shutdown – a bitfield with errors to emergency shutdown the vehicle. 112 - 113 -=== ATIB charger === 114 - 115 -To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → ATIB charger" section: 116 -[[image:1739294769684-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="600"]] 117 - 118 -In this section: 119 - 120 -* Enable – a flag to enable communication with the charger; 121 -* CAN port – port which is used to communicate with the charger: 122 -** CAN1 (ext); 123 -** CAN2 (int); 124 -* Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 125 -* Output period - a period of sending commands to the charger, millisecond; 126 -* Charging voltage – maximum charging voltage, V; 127 -* Charging current – maximum charging current, A; 128 -* Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 129 - 130 -(% class="box infomessage" %) 131 -((( 132 -After changing the settings, restart the BMS Main 3X device. 133 -))) 134 - 135 - 81 +[[image:1739294567774-840.png]]
- 1739294769684-405.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.5 KB - Content
- 1739970298499-463.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -85.1 KB - Content