Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -72,17 +72,22 @@ 72 72 * Alarm threshold – a threshold resistance value to set insulation alarm, Ohm; 73 73 * Warning threshold – a threshold resistance value to set insulation warning, Ohm. 74 74 75 -=== 75 +=== Unibat vehicle === 76 76 77 77 To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 78 78 79 -[[image:1739294 567774-840.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="600"]]In this section:79 +[[image:1739970298499-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="302" width="600"]] 80 80 81 +In this section: 82 + 81 81 * Enable – a flag to enable communication with the vehicle; 82 82 * CAN port – port which is used to communicate with the vehicle; 85 +* BMS address; 86 +* VCU address; 83 83 * Use CRC – a flag to enable checking the checksum of the control message; 84 84 * Use DTC – a flag to enable transmit of error codes on battery failures; 85 85 * Use additional current sensors to determine error – a flag to use measuring of second and third current sensor to determine errors in battery work; 90 +* Invert discharge current limit; 86 86 * Number of modules – total number of battery modules; 87 87 * Receive timeout – a timeout for receiving packets from the vehicle (if there is no messages during that time, an error generates), millisecond; 88 88 * HVIL delay – a delay before generating a signal of high-voltage interrupt loop breakage, millisecond;