Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/04/09 12:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,24 +14,8 @@ 14 14 15 15 [[image:1734022225578-818.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="600"]] 16 16 17 - Thedevice supportsthefollowingassignments fordiscreteinputs:17 +A list of available discrete input assignments is available in [[Input signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 18 18 19 -* No input – input is not used; 20 -* Battery cover – a signal from the battery cover; 21 -* Charge request – a request to close the charging contactor; 22 -* Precharge request – a request to close the precharging contactor; 23 -* Discharge request – a request to close the discharging contactor; 24 -* Charging contactor feedback – a signal from charging contactor feedback loop; 25 -* Discharging contactor feedback – a signal from discharging contactor feedback loop; 26 -* Charging/Discharging contactor feedback – a signal from charging/discharging contactor feedback loop; 27 -* Insulation status – a signal from an insulation monitoring device; 28 -* Join to charge – a request to join (connect in parallel) battery modules to charge the battery; 29 -* Join to discharge – a request to join (connect in parallel) battery modules to discharge the battery; 30 -* Precharge contactor feedback – a signal from precharging contactor feedback loop; 31 -* Main contactor feedback – a signal from main contactor feedback loop; 32 -* Interlock – a signal from interlock loop; 33 -* Power down request – a request to power down the BMS. 34 - 35 35 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 36 36 37 37 [[image:1734022225583-740.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="600"]] ... ... @@ -102,19 +102,8 @@ 102 102 103 103 [[image:1734022225588-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="131" width="600"]] 104 104 105 - The devicesupportsthefollowingassignments fordiscreteoutputs:89 +A list of available discrete output assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 106 106 107 -* No output – output is not used. 108 -* Charging – state of the charging contactor; 109 -* Discharging – state of the discharging contactor; 110 -* Charging/Discharging - state of the charging/discharging contactor; 111 -* Precharging – state of the precharging contactor; 112 -* Heater – a command to turn on a heater; 113 -* Cooler – a command to turn on a cooler; 114 -* Main contactor – state of the main contactor; 115 -* Critical error – a signal indicating there is a Critical error on BMS Main 3X; 116 -* General error (modules) – a signal indicating there is a General error on one of the modules; 117 - 118 118 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 119 119 120 120 [[image:1734022225589-659.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="600"]] ... ... @@ -128,7 +128,7 @@ 128 128 129 129 [[image:1734022225590-811.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="600"]] 130 130 131 - The devicesupportsthe sameswitchassignments asdiscreteoutputs.104 +A list of available discrete output assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 132 132 133 133 Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section: 134 134