Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/04/09 12:33

From version 2.5
edited by Admin
on 2025/01/28 16:02
Change comment: There is no comment for this version
To version 4.1
edited by Admin
on 2025/02/11 15:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,24 +14,8 @@
14 14  
15 15  [[image:1734022225578-818.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="600"]]
16 16  
17 -The device supports the following assignments for discrete inputs:
17 +A list of available discrete input assignments is available in [[Input signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
18 18  
19 -* No input – input is not used;
20 -* Battery cover – a signal from the battery cover;
21 -* Charge request – a request to close the charging contactor;
22 -* Precharge request – a request to close the precharging contactor;
23 -* Discharge request – a request to close the discharging contactor;
24 -* Charging contactor feedback – a signal from charging contactor feedback loop;
25 -* Discharging contactor feedback – a signal from discharging contactor feedback loop;
26 -* Charging/Discharging contactor feedback – a signal from charging/discharging contactor feedback loop;
27 -* Insulation status – a signal from an insulation monitoring device;
28 -* Join to charge – a request to join (connect in parallel) battery modules to charge the battery;
29 -* Join to discharge – a request to join (connect in parallel) battery modules to discharge the battery;
30 -* Precharge contactor feedback – a signal from precharging contactor feedback loop;
31 -* Main contactor feedback – a signal from main contactor feedback loop;
32 -* Interlock – a signal from interlock loop;
33 -* Power down request – a request to power down the BMS.
34 -
35 35  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
36 36  
37 37  [[image:1734022225583-740.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="600"]]
... ... @@ -102,19 +102,8 @@
102 102  
103 103  [[image:1734022225588-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="131" width="600"]]
104 104  
105 -The device supports the following assignments for discrete outputs:
89 +A list of available discrete output assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
106 106  
107 -* No output – output is not used.
108 -* Charging – state of the charging contactor;
109 -* Discharging – state of the discharging contactor;
110 -* Charging/Discharging - state of the charging/discharging contactor;
111 -* Precharging – state of the precharging contactor;
112 -* Heater – a command to turn on a heater;
113 -* Cooler – a command to turn on a cooler;
114 -* Main contactor – state of the main contactor;
115 -* Critical error – a signal indicating there is a Critical error on BMS Main 3X;
116 -* General error (modules) – a signal indicating there is a General error on one of the modules;
117 -
118 118  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
119 119  
120 120  [[image:1734022225589-659.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="600"]]
... ... @@ -128,7 +128,7 @@
128 128  
129 129  [[image:1734022225590-811.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="600"]]
130 130  
131 -The device supports the same switch assignments as discrete outputs.
104 +A list of available discrete output assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
132 132  
133 133  Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section:
134 134