Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/04/09 12:33
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 3X.3\. Configuration.WebHome1 +Battery management systems.BMS Main 3X.3\. Configuration.WebHome - Content
-
... ... @@ -1,0 +1,119 @@ 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 3 + 4 +(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 +== Inputs and outputs == 6 + 7 +=== Discrete inputs === 8 + 9 +The BMS Main 3X device has **6 discrete inputs** that detect signal line closing to the virtual ground, and **2 inputs** that detect 9-32V input voltage. For each discrete input, its assignment and inversion flag are set. 10 + 11 +Also, BMS has two additional configurable inputs named “KEYRUN” and “CHARGE_ON”, each serves 9-32V input voltage. Those inputs serve as power buttons with additional functions that can be set. 12 + 13 +Assignments of discrete inputs are configured in the "Signals → Input discrete signals → Assignments" section: 14 + 15 +[[image:1734022225578-818.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="600"]] 16 + 17 +(% class="box infomessage" %) 18 +((( 19 +A list of available discrete input assignments is available in [[Input signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 20 +))) 21 + 22 +Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 23 + 24 +[[image:1734022225583-740.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="600"]] 25 + 26 +The behavior of “KEYRUN” signal can be configured in the "Signals → Input discrete signals → KEYRUN mode" section: 27 + 28 +[[image:1734022225584-474.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="600"]] 29 + 30 +The behavior of “CHARGE_ON” signal can be configured in the "Signals → Input discrete signals → CHARGE_ON mode" section: 31 + 32 +[[image:1734022225585-775.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="89" width="600"]] 33 + 34 +In both “KEYRUN mode” and “CHARGE_ON mode” sections: 35 + 36 +* Do nothing – power on device and do nothing; 37 +* Set “Join to discharge” – power on device and set “Join to discharge” signal immediately; 38 +* Set “Join to charge” – power on device and set “Join to charge” signal immediately; 39 +* Set “Discharge request” – power on device and set “Discharge request” signal immediately; 40 +* Set “Charge request” – power on device and set “Charge request” signal immediately. 41 + 42 +=== Current sensor === 43 + 44 +The BMS Main 3X device has an ability to measure battery current by **3 external Hall-Effect current sensors**. 45 + 46 +Current sensor settings are configured in the "Signals → Current sensor" section: 47 + 48 +[[image:1734022225586-287.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="600"]] 49 + 50 +The device supports the following current sensor settings: 51 + 52 +* Calculate the battery current as the sum of battery modules currents – a flag that determines overall current as sum of battery modules currents (if flag is not set, device uses measurements from a physical current sensor); 53 +* Connection – type of multiple sensors connection 54 +** One sensor (#1) – only first sensor is used to measure the battery current; 55 +** Two sensors (#1 and #2) in parallel – sensors are connected in parallel (the total battery current equals the sum of two sensors); 56 +** Two sensors (#1 and #2) in different branches – sensors located in two halves of the battery (used in batteries with a middle point); 57 +* Sensor 2, 3: Enable – a flag to enable the second of third current sensor; 58 +* Sensor 1, 2, 3: Nominal current – rated current I,,nom,, of the sensor according to the datasheet, A; 59 +* Sensor 1, 2, 3: Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nom.,,; 60 +* Sensor 1, 2, 3: Invert – invert the sign of the measured value; 61 +* Sensor 1, 2, 3: Multiply charging current (experimental) – an experimental flag for scaling the charging current by given multiplier; 62 +* Sensor 1, 2, 3: Multiplier for charging current – charging current multiplier; 63 +* Sensor 1, 2, 3: REF_IN2 mode – mode of additional analog line: 64 +** Not connected; 65 +** Reference line – reference output of the sensor; 66 +** Low range (for the dual range sensor) - a second output of a dual-range sensor (for example, LEM DHAB series); 67 +* Sensor 1, 2, 3: Low range nominal current - rated current I,,nom,, of the low current line of dual range sensor according to the datasheet, A; 68 +* Sensor 1, 2, 3: Low range sensitivity – sensitivity of the low current line of dual range sensor according to the datasheet, V / I,,nominal.,,; 69 +* Sensor 1, 2, 3: Threshold for low range – a threshold current value at which the device uses the readings of the high current sensor instead of low current, A; 70 +* Calibrate – a flag to calibrate (find a 0A point) the current sensor when the device is started; 71 +* Calibration time – calibration time of the current sensor, millisecond; 72 +* Recalibrate current sensor – a command to calibrate the current sensor manually. 73 + 74 +=== Temperature sensors === 75 + 76 +Temperature sensors settings are configured in the "Signals → Temperature sensors" section: 77 + 78 +[[image:1734022225587-758.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="58" width="600"]] 79 + 80 +In this section: 81 + 82 +* Type – a type of temperature sensors. 83 + 84 +=== Output discrete signals === 85 + 86 +The BMS Main 3X device has **4 open drain outputs**. For each discrete output, its assignment and inversion flag are set. 87 + 88 +Assignments of discrete outputs are configured in the "Signals → Output discrete signals → Assignments" section: 89 + 90 +[[image:1734022225588-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="131" width="600"]] 91 + 92 +(% class="box infomessage" %) 93 +((( 94 +A list of available discrete output assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 95 +))) 96 + 97 +Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 98 + 99 +[[image:1734022225589-659.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="600"]] 100 + 101 + 102 +=== Power switches === 103 + 104 +The BMS Main 3X device has **6 power switches to drive contactors**. For each switch, its assignment and inversion flag are set. 105 + 106 +Assignments of power switches are configured in the "Signals → Power switches → Assignments" section: 107 + 108 +[[image:1734022225590-811.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="600"]] 109 + 110 +(% class="box infomessage" %) 111 +((( 112 +A list of available discrete output assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 113 +))) 114 + 115 +Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section: 116 + 117 +[[image:1734022225591-262.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="600"]] 118 + 119 +
- 1734022225578-818.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.1 KB - Content
- 1734022225583-740.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.3 KB - Content
- 1734022225584-474.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.2 KB - Content
- 1734022225585-775.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.5 KB - Content
- 1734022225586-287.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.4 KB - Content
- 1734022225587-758.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.7 KB - Content
- 1734022225588-223.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.4 KB - Content
- 1734022225589-659.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.4 KB - Content
- 1734022225590-811.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.1 KB - Content
- 1734022225591-262.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.2 KB - Content