Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/04/09 12:33
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 10 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -3.2 1 +3.2 Inputs and outputs - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 3X.3\. Configuration.WebHome1 +Battery management systems.BMS Main 3X.3\. Configuration.WebHome - Content
-
... ... @@ -1,0 +1,135 @@ 1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += Configuration = 3 + 4 +(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 +== Inputs and outputs == 6 + 7 +=== Discrete inputs === 8 + 9 +The BMS Main 3X device has **6 discrete inputs** that detect signal line closing to the virtual ground, and **2 inputs** that detect 9-32V input voltage. For each discrete input, its assignment and inversion flag are set. 10 + 11 +Also, BMS has two additional configurable inputs named “KEYRUN” and “CHARGE_ON”, each serves 9-32V input voltage. Those inputs serve as power buttons with additional functions that can be set. 12 + 13 +Assignments of discrete inputs are configured in the "Signals → Input discrete signals → Assignments" section: 14 + 15 +[[image:1734022225578-818.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="600"]] 16 + 17 +The device supports the following assignments for discrete inputs: 18 + 19 +* No input – input is not used; 20 +* Battery cover – a signal from the battery cover; 21 +* Charge request – a request to close the charging contactor; 22 +* Precharge request – a request to close the precharging contactor; 23 +* Discharge request – a request to close the discharging contactor; 24 +* Charging contactor feedback – a signal from charging contactor feedback loop; 25 +* Discharging contactor feedback – a signal from discharging contactor feedback loop; 26 +* Charging/Discharging contactor feedback – a signal from charging/discharging contactor feedback loop; 27 +* Insulation status – a signal from an insulation monitoring device; 28 +* Join to charge – a request to join (connect in parallel) battery modules to charge the battery; 29 +* Join to discharge – a request to join (connect in parallel) battery modules to discharge the battery; 30 +* Precharge contactor feedback – a signal from precharging contactor feedback loop; 31 +* Main contactor feedback – a signal from main contactor feedback loop; 32 +* Interlock – a signal from interlock loop; 33 +* Power down request – a request to power down the BMS. 34 + 35 +Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 36 + 37 +[[image:1734022225583-740.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="600"]] 38 + 39 +The behavior of “KEYRUN” signal can be configured in the "Signals → Input discrete signals → KEYRUN mode" section: 40 + 41 +[[image:1734022225584-474.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="600"]] 42 + 43 +The behavior of “CHARGE_ON” signal can be configured in the "Signals → Input discrete signals → CHARGE_ON mode" section: 44 + 45 +[[image:1734022225585-775.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="89" width="600"]] 46 + 47 +In both “KEYRUN mode” and “CHARGE_ON mode” sections: 48 + 49 +* Do nothing – power on device and do nothing; 50 +* Set “Join to discharge” – power on device and set “Join to discharge” signal immediately; 51 +* Set “Join to charge” – power on device and set “Join to charge” signal immediately; 52 +* Set “Discharge request” – power on device and set “Discharge request” signal immediately; 53 +* Set “Charge request” – power on device and set “Charge request” signal immediately. 54 + 55 +=== Current sensor === 56 + 57 +The BMS Main 3X device has an ability to measure battery current by **3 external Hall-Effect current sensors**. 58 + 59 +Current sensor settings are configured in the "Signals → Current sensor" section: 60 + 61 +[[image:1734022225586-287.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="600"]] 62 + 63 +The device supports the following current sensor settings: 64 + 65 +* Calculate the battery current as the sum of battery modules currents – a flag that determines overall current as sum of battery modules currents (if flag is not set, device uses measurements from a physical current sensor); 66 +* Connection – type of multiple sensors connection 67 +** One sensor (#1) – only first sensor is used to measure the battery current; 68 +** Two sensors (#1 and #2) in parallel – sensors are connected in parallel (the total battery current equals the sum of two sensors); 69 +** Two sensors (#1 and #2) in different branches – sensors located in two halves of the battery (used in batteries with a middle point); 70 +* Sensor 2, 3: Enable – a flag to enable the second of third current sensor; 71 +* Sensor 1, 2, 3: Nominal current – rated current I,,nom,, of the sensor according to the datasheet, A; 72 +* Sensor 1, 2, 3: Sensitivity – sensitivity of the current sensor according to the datasheet, V / I,,nom.,,; 73 +* Sensor 1, 2, 3: Invert – invert the sign of the measured value; 74 +* Sensor 1, 2, 3: Multiply charging current (experimental) – an experimental flag for scaling the charging current by given multiplier; 75 +* Sensor 1, 2, 3: Multiplier for charging current – charging current multiplier; 76 +* Sensor 1, 2, 3: REF_IN2 mode – mode of additional analog line: 77 +** Not connected; 78 +** Reference line – reference output of the sensor; 79 +** Low range (for the dual range sensor) - a second output of a dual-range sensor (for example, LEM DHAB series); 80 +* Sensor 1, 2, 3: Low range nominal current - rated current I,,nom,, of the low current line of dual range sensor according to the datasheet, A; 81 +* Sensor 1, 2, 3: Low range sensitivity – sensitivity of the low current line of dual range sensor according to the datasheet, V / I,,nominal.,,; 82 +* Sensor 1, 2, 3: Threshold for low range – a threshold current value at which the device uses the readings of the high current sensor instead of low current, A; 83 +* Calibrate – a flag to calibrate (find a 0A point) the current sensor when the device is started; 84 +* Calibration time – calibration time of the current sensor, millisecond; 85 +* Recalibrate current sensor – a command to calibrate the current sensor manually. 86 + 87 +=== Temperature sensors === 88 + 89 +Temperature sensors settings are configured in the "Signals → Temperature sensors" section: 90 + 91 +[[image:1734022225587-758.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="58" width="600"]] 92 + 93 +In this section: 94 + 95 +* Type – a type of temperature sensors. 96 + 97 +=== Output discrete signals === 98 + 99 +The BMS Main 3X device has **4 open drain outputs**. For each discrete output, its assignment and inversion flag are set. 100 + 101 +Assignments of discrete outputs are configured in the "Signals → Output discrete signals → Assignments" section: 102 + 103 +[[image:1734022225588-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="131" width="600"]] 104 + 105 +The device supports the following assignments for discrete outputs: 106 + 107 +* No output – output is not used. 108 +* Charging – state of the charging contactor; 109 +* Discharging – state of the discharging contactor; 110 +* Charging/Discharging - state of the charging/discharging contactor; 111 +* Precharging – state of the precharging contactor; 112 +* Heater – a command to turn on a heater; 113 +* Cooler – a command to turn on a cooler; 114 +* Main contactor – state of the main contactor. 115 + 116 +Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 117 + 118 +[[image:1734022225589-659.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="118" width="600"]] 119 + 120 + 121 +=== Power switches === 122 + 123 +The BMS Main 3X device has **6 power switches to drive contactors**. For each switch, its assignment and inversion flag are set. 124 + 125 +Assignments of power switches are configured in the "Signals → Power switches → Assignments" section: 126 + 127 +[[image:1734022225590-811.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="600"]] 128 + 129 +The device supports the same switch assignments as discrete outputs. 130 + 131 +Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section: 132 + 133 +[[image:1734022225591-262.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="600"]] 134 + 135 +
- 1734022225578-818.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.1 KB - Content
- 1734022225583-740.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.3 KB - Content
- 1734022225584-474.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.2 KB - Content
- 1734022225585-775.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.5 KB - Content
- 1734022225586-287.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.4 KB - Content
- 1734022225587-758.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.7 KB - Content
- 1734022225588-223.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.4 KB - Content
- 1734022225589-659.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.4 KB - Content
- 1734022225590-811.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.1 KB - Content
- 1734022225591-262.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.2 KB - Content