Wiki source code of 4.5 External equipment
Last modified by Admin on 2024/12/26 16:33
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) | ||
2 | = Monitoring = | ||
3 | |||
4 | (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) | ||
5 | == External equipment == | ||
6 | |||
7 | Information about the status of external equipment is in the "External equipment" section. | ||
8 | |||
9 | === J1939 Charger === | ||
10 | |||
11 | Information about the status of communication with a J1939 charger is available in the "External equipment → Chargers → J1939 charger" section: | ||
12 | |||
13 | [[image:1733403615335-586.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="800"]] | ||
14 | |||
15 | In this section: | ||
16 | |||
17 | * Online – a flag indicating if the connection with the charger is established; | ||
18 | * Voltage – a value of voltage received from the charger, V; | ||
19 | * Current – a value of current received from the charger, А. | ||
20 | |||
21 | === Eltek charger === | ||
22 | |||
23 | Information about the status of communication with an Eltek charger is available in the "External equipment → Chargers → Eltek charger" section: | ||
24 | |||
25 | [[image:1733403615338-449.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="166" width="800"]] | ||
26 | |||
27 | In this section: | ||
28 | |||
29 | * Status: | ||
30 | ** Offline – no connection with charger; | ||
31 | ** No charge; | ||
32 | ** Charge; | ||
33 | ** Recoverable error; | ||
34 | ** Non-recoverable error; | ||
35 | * Input voltage, V; | ||
36 | * Input current, А; | ||
37 | * Input frequency, Hz; | ||
38 | * Output voltage, V; | ||
39 | * Output current, А; | ||
40 | * Primary temperature – temperature measured by the main temperature sensor, °C; | ||
41 | * Secondary temperature – temperature measured by an additional temperature sensor, °C; | ||
42 | * Max power – maximum power that the charger can provide, W; | ||
43 | * Available power, %; | ||
44 | * Errors – hexadecimal word with charger errors. | ||
45 | |||
46 | === MicroPower charger === | ||
47 | |||
48 | Information about the status of communication with a MicroPower charger is available in the "External equipment → Chargers → MicroPower charger" section: | ||
49 | |||
50 | [[image:1733403615339-883.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="146" width="800"]] | ||
51 | |||
52 | In this section: | ||
53 | |||
54 | * Online – a flag of normal communication with the charger; | ||
55 | * Voltage, V; | ||
56 | * Current, A; | ||
57 | * Power, W; | ||
58 | * Charge information: | ||
59 | ** Voltage reached – output voltage of the charger is close to the required value; | ||
60 | ** Current reached – output current of the charger is close to the required value; | ||
61 | ** Power reached – output power of the charger is close to the required value; | ||
62 | * Limiter mode: | ||
63 | ** None; | ||
64 | ** Voltage; | ||
65 | ** Current; | ||
66 | ** Power; | ||
67 | ** Int. temperature – output is limited due to internal charger temperature; | ||
68 | ** Volt. boundary – bound voltage is reached; | ||
69 | ** Curr. boundary – bound current is reached; | ||
70 | ** Pow. boundary – bound power is reached; | ||
71 | ** DC limit; | ||
72 | ** AC limit; | ||
73 | ** Pow. AC limit – input power limitation; | ||
74 | ** Phase error; | ||
75 | * Cause of derate: | ||
76 | ** Phase error; | ||
77 | ** Parameters; | ||
78 | ** Poor power; | ||
79 | ** Internal temperature; | ||
80 | ** No load; | ||
81 | * Warnings, Errors: | ||
82 | ** Phase error; | ||
83 | ** Regulator error; | ||
84 | ** Low temperature; | ||
85 | ** High temperature; | ||
86 | ** Temperature protection; | ||
87 | ** CAN timeout. | ||
88 | |||
89 | === S.P.E. charger === | ||
90 | |||
91 | Information about the status of communication with an S.P.E. charger is available in the "External equipment → Chargers → S.P.E. charger" section: | ||
92 | |||
93 | [[image:1733403615340-774.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="80" width="800"]] | ||
94 | |||
95 | In this section: | ||
96 | |||
97 | * Online – a flag of normal communication with the charger; | ||
98 | * Voltage, V; | ||
99 | * Current, A. | ||
100 | |||
101 | === Bassi charger === | ||
102 | |||
103 | Information about the status of communication with a Bassi charger is available in the "External equipment → Chargers → Bassi charger" section: | ||
104 | |||
105 | [[image:1733403627269-810.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]] | ||
106 | |||
107 | In this section: | ||
108 | |||
109 | * Online – a flag of normal communication with the charger; | ||
110 | * Voltage – voltage measured by the charger, V; | ||
111 | * Current – current measured by the charger, A; | ||
112 | * Internal temperature – temperature of the charger, °C; | ||
113 | * Charge – energy which the charger transferred to the battery, Ah; | ||
114 | * Charging time – duration of the battery charging, minute. | ||
115 | |||
116 | === ATIB charger === | ||
117 | |||
118 | Information about the status of communication with an ATIB charger is available in the "External equipment → Chargers → ATIB charger" section: | ||
119 | |||
120 | [[image:1733403627273-306.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="800"]] | ||
121 | |||
122 | In this section: | ||
123 | |||
124 | * Online – a flag of normal communication with the charger; | ||
125 | * Voltage – voltage measured by the charger, V; | ||
126 | * Current – current measured by the charger, A; | ||
127 | * Status – bitfield with status indicators: | ||
128 | ** Charger error; | ||
129 | ** High temperature; | ||
130 | ** Parameters out of limits; | ||
131 | ** Battery is not connected; | ||
132 | ** Communication error; | ||
133 | ** Thermal derating; | ||
134 | ** Precharge. | ||
135 | |||
136 | === Fronius charger === | ||
137 | |||
138 | Information about the status of communication with a Fronius charger is available in the "External equipment → Chargers → Fronius charger" section: | ||
139 | |||
140 | [[image:1733403627280-868.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="800"]] | ||
141 | |||
142 | In this section: | ||
143 | |||
144 | * Online – a flag of normal communication with the charger; | ||
145 | * Voltage – voltage measured by the charger, V; | ||
146 | * Current – current measured by the charger, A; | ||
147 | * Status – bitfield with status indicators: | ||
148 | ** Power unit on – charger power status; | ||
149 | ** Voltage match finish – charging finished due to voltage achievement; | ||
150 | ** Delay; | ||
151 | ** Derating; | ||
152 | ** Error – charger error; | ||
153 | ** Break – charging stopped. | ||
154 | |||
155 | === Webasto charger === | ||
156 | |||
157 | Information about the status of communication with a Webasto charger is available in the "External equipment → Chargers → Webasto charger" section: | ||
158 | |||
159 | [[image:1733403627282-942.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]] | ||
160 | |||
161 | In this section: | ||
162 | |||
163 | * Online – a flag of normal communication with the charger; | ||
164 | * Voltage – voltage measured by the charger, V; | ||
165 | * Available current – maximum allowable charging current, A; | ||
166 | * Actual current – current measured by the charger, A; | ||
167 | * Status – bitfield with status indicators: | ||
168 | ** Ready to charge; | ||
169 | ** Charging – battery is charging; | ||
170 | ** High temperature – charger is overheated; | ||
171 | ** Fault state – charger error. | ||
172 | |||
173 | === Skytronic charger === | ||
174 | |||
175 | Information about the status of communication with a Skytronic charger is available in the "External equipment → Chargers → Skytronic charger" section: | ||
176 | |||
177 | [[image:1733403627283-582.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="78" width="800"]] | ||
178 | |||
179 | In this section: | ||
180 | |||
181 | * Online – a flag of normal communication with the charger; | ||
182 | * Voltage – voltage measured by the charger, V; | ||
183 | * Actual current – current measured by the charger, A. | ||
184 | |||
185 | === CCS Fast charge controller === | ||
186 | |||
187 | Information about the status of communication with a CCS Fast charge controller is available in the "External equipment → Chargers → CCS Fast charge controller" section: | ||
188 | |||
189 | [[image:1733403627284-333.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]] | ||
190 | |||
191 | In this section: | ||
192 | |||
193 | * CCS Controller online – a flag of normal communication with the charger; | ||
194 | * Ovartech charger online; | ||
195 | * BMS State; | ||
196 | * CCS state machine; | ||
197 | * Temperature of contactors DC, ºC; | ||
198 | * Temperature of contactors AC, ºC; | ||
199 | * Voltage – voltage measured by the charger, V; | ||
200 | * Current – current measured by the charger, A; | ||
201 | * Ovartech status. | ||
202 | |||
203 | === SMA Sunny Island inverter === | ||
204 | |||
205 | Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → SMA Sunny Island inverter " section: | ||
206 | |||
207 | [[image:1733403635784-523.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="142" width="800"]] | ||
208 | |||
209 | In this section: | ||
210 | |||
211 | * Voltage, V. | ||
212 | * Current, A; | ||
213 | * Tempareture, °C; | ||
214 | * SOC, %; | ||
215 | * SOH, %; | ||
216 | * Mode – inverter working mode code; | ||
217 | * State – inverter state code; | ||
218 | * Error – inverter error code; | ||
219 | * Charging voltage, V. | ||
220 | |||
221 | === Pylontech inverter === | ||
222 | |||
223 | Information about the status of communication with a Pylontech inverter is available in the "External equipment → Inverters → Pylontech inverter" section: | ||
224 | |||
225 | [[image:1733403635786-143.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="81" width="800"]] | ||
226 | |||
227 | In this section: | ||
228 | |||
229 | * Online – a flag of normal communication with the inverter; | ||
230 | |||
231 | === ASTOM load bank (cycling) === | ||
232 | |||
233 | Information about the status of communication with a ASTOM load bank is available in the "External equipment → Inverters → ASTOM load bank (cycling)" section: | ||
234 | |||
235 | [[image:1733403635787-879.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]] | ||
236 | |||
237 | In this section: | ||
238 | |||
239 | * Current state – current state of the cycle algorithm; | ||
240 | * Time elapsed, second; | ||
241 | * Number of completed cycles; | ||
242 | * Load bank online; | ||
243 | * Load current, A; | ||
244 | * Input voltage, V; | ||
245 | * Maximim DOD – maximum measured DOD during cycling, Ah; | ||
246 | * Logic index – BMS Logic identifier with fastest discharging cell connected; | ||
247 | * Cell index – number of fastest discharging cell; | ||
248 | * Start cycling – a trigger to start cycling. | ||
249 | |||
250 | === HYG Class I-III truck === | ||
251 | |||
252 | Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section: | ||
253 | |||
254 | [[image:1733403635788-858.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]] | ||
255 | |||
256 | In this section: | ||
257 | |||
258 | * Online – a flag of normal communication with the forklift; | ||
259 | * Voltage, V; | ||
260 | * Current, А; | ||
261 | * Temperature, °C; | ||
262 | * Thermal derate, %; | ||
263 | * Control – bitfield with control commands transferred to the forklift: | ||
264 | ** Inhibit operation; | ||
265 | ** Immediate shutdown; | ||
266 | ** Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value); | ||
267 | ** Traction inhibit (Gen.2: charger connected); | ||
268 | ** Lift lockout – blocking of the lift (it is formed if the battery SOC is less than the “SOC: Lift lockout” value). | ||
269 | |||
270 | === Combilift truck === | ||
271 | |||
272 | Information about the status of communication with a Combilift truck is available in the "External equipment → Trucks and Vehicles → Combilift truck" section: | ||
273 | |||
274 | [[image:1733403635788-647.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]] | ||
275 | |||
276 | In this section: | ||
277 | |||
278 | * Online – a flag of normal communication with equipment; | ||
279 | * Voltage, V; | ||
280 | * Current, А; | ||
281 | * Temperature, °C; | ||
282 | * Control – bitfield with control commands transferred to the forklift: | ||
283 | ** Power shutdown – turn off the forklift power; | ||
284 | ** Traction inhibit; | ||
285 | ** Lift lockout – blocking of the lift (it is formed if the battery SOC is less than the “SOC: Lift lockout” value); | ||
286 | |||
287 | Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value). | ||
288 | |||
289 | === Spirit AGV === | ||
290 | |||
291 | Information about the status of communication with a Spirit AGV is available in the "External equipment → Trucks and Vehicles → Spirit AGV" section: | ||
292 | |||
293 | [[image:1733403652587-929.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="136" width="800"]] | ||
294 | |||
295 | In this section: | ||
296 | |||
297 | * Online – a flag of normal communication with the truck; | ||
298 | * Voltage, V; | ||
299 | * Current, A; | ||
300 | * Temperature, °C; | ||
301 | * Control 1 – first bitfield with control commands transferred to the forklift: | ||
302 | ** Inhibit operation; | ||
303 | ** Immediate shutdown; | ||
304 | ** Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value); | ||
305 | ** Traction inhibit; | ||
306 | ** Lift lockout – blocking of the lift (it is formed if the battery SOC is less than the “SOC: Lift lockout” value). | ||
307 | * Control 2 – second bitfield with control commands transferred to the forklift: | ||
308 | ** Charger connected; | ||
309 | ** No charging or discharging current; | ||
310 | ** Charging; | ||
311 | ** Discharging; | ||
312 | ** Logic offline / Cell count error / Battery cover opened; | ||
313 | ** Overcurrent / Overvoltage / Undervoltage; | ||
314 | ** High temperature / Low temperature; | ||
315 | ** Board high temperature. | ||
316 | * Status – forklift status sent to BMS: | ||
317 | ** Shutdown immediately; | ||
318 | ** Confirmed shutdown; | ||
319 | ** Charging / not charging; | ||
320 | ** Charger critical error; | ||
321 | ** Charger non-critical error; | ||
322 | * Waiting time, second. | ||
323 | |||
324 | === Crown truck === | ||
325 | |||
326 | Information about the status of communication with a Crown truck is available in the "External equipment → Trucks and Vehicles → Crown truck" section: | ||
327 | |||
328 | [[image:1733403652588-762.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="800"]] | ||
329 | |||
330 | In this section: | ||
331 | |||
332 | * Voltage A2 (from battery) – voltage measured by the BMS Crown on battery, V; | ||
333 | * Voltage A1 (from truck) – voltage produced by the Crown forklift system, V; | ||
334 | * Relay – command to power on the Crown forklift. | ||
335 | |||
336 | === ZiK truck === | ||
337 | |||
338 | Information about the status of communication with a ZiK truck is available in the "External equipment → Trucks and Vehicles → ZiK truck" section: | ||
339 | |||
340 | [[image:1733403652588-674.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="165" width="800"]] | ||
341 | |||
342 | In this section: | ||
343 | |||
344 | * Battery voltage, V; | ||
345 | * Battery current, A; | ||
346 | * Supercapacitor voltage, V; | ||
347 | * Supercapacitor temperature, °C; | ||
348 | * Control – bitfield with control commands transferred to the forklift: | ||
349 | ** Discharging; | ||
350 | ** Allow discharging; | ||
351 | ** Charge supercapacitor; | ||
352 | ** Recuperation resistor; | ||
353 | ** Inhibit operation; | ||
354 | ** Undervoltage; | ||
355 | ** Overcurrent; | ||
356 | ** Limited operation. | ||
357 | |||
358 | === Evocargo Evo1.1 truck === | ||
359 | |||
360 | Information about the status of communication with an Evocargo Evo1.1 truck is available in the "External equipment → Trucks and Vehicles → Evocargo Evo1.1 truck" section: | ||
361 | |||
362 | [[image:1733403652589-965.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="111" width="800"]] | ||
363 | |||
364 | In this section: | ||
365 | |||
366 | * Online – a flag of normal communication with the truck; | ||
367 | * Emulate control signals – a flag to emulate control signals; | ||
368 | * Emulation: Charge permission – a flag to emulate charge permission; | ||
369 | * Emulation Insulation control – a flag to emulate insulation control; | ||
370 | * Charge permission – state of “Charge permission” signal; | ||
371 | * Insulation control – state of “Insulation control” signal; | ||
372 | |||
373 | === BKM vehicle === | ||
374 | |||
375 | Information about the status of communication with a BKM vehicle is available in the "External equipment → Trucks and Vehicles → BKM vehicle" section: | ||
376 | |||
377 | [[image:1733403652590-860.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="80" width="800"]] | ||
378 | |||
379 | In this section: | ||
380 | |||
381 | * Vehicle online – a flag of normal communication with the vehicle; | ||
382 | * Charger online – a flag of normal communication with the charger; | ||
383 | |||
384 | === Basic J1939 vehicle === | ||
385 | |||
386 | Information about the status of communication with a vehicle via the J1939 protocol is available in the "External equipment → Trucks and Vehicles → Basic J1939 vehicle" section: | ||
387 | |||
388 | [[image:1733403652590-841.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]] | ||
389 | |||
390 | In this section: | ||
391 | |||
392 | * Online – a flag of normal communication with the vehicle; | ||
393 | * Maximum DOD – maximum allowed DOD of the battery, %. | ||
394 | |||
395 | === Bender iso165C === | ||
396 | |||
397 | Information about the status of communication with Bender iso165C is available in the "External equipment → IMD → Bender iso165C" section: | ||
398 | |||
399 | [[image:1733403652591-578.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] | ||
400 | |||
401 | In this section: | ||
402 | |||
403 | * Online – a flag of normal communication with the IMD; | ||
404 | * Configured – a flag indicating successful device set up; | ||
405 | * Status – device status; | ||
406 | * Insulation resistance – measured insulation resistance, Ohm. | ||
407 | |||
408 | === BMS IMD === | ||
409 | |||
410 | Information about the status of communication with BMS IMD is available in the "External equipment → IMD → BMS IMD" section: | ||
411 | |||
412 | [[image:1733403652592-578.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="122" width="800"]] | ||
413 | |||
414 | In this section: | ||
415 | |||
416 | * Online – a flag of normal communication with the IMD; | ||
417 | * Configured – a flag indicating successful device set up; | ||
418 | * Insulation status; | ||
419 | * Internal errors – internal device errors; | ||
420 | * Device state – device status; | ||
421 | * Insulation resistance (plus) – measured insulation resistance between positive line and chassis, Ohm; | ||
422 | * Insulation resistance (minus) – measured insulation resistance between negative line and chassis, Ohm. | ||
423 | |||
424 | === Main X === | ||
425 | |||
426 | Information about the status of communication with BMS Main X is available in the "External equipment → BMS → Main X" section: | ||
427 | |||
428 | [[image:1733403652592-229.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]] | ||