Changes for page 4.5 External equipment

Last modified by Admin on 2024/12/26 16:33

From version 1.4
edited by Admin
on 2024/12/26 16:33
Change comment: There is no comment for this version
To version 1.3
edited by Admin
on 2024/12/11 11:33
Change comment: Update document after refactoring.

Summary

Details

Page properties
Content
... ... @@ -170,36 +170,6 @@
170 170  ** High temperature – charger is overheated;
171 171  ** Fault state – charger error.
172 172  
173 -=== Skytronic charger ===
174 -
175 -Information about the status of communication with a Skytronic charger is available in the "External equipment → Chargers → Skytronic charger" section:
176 -
177 -[[image:1733403627283-582.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="78" width="800"]]
178 -
179 -In this section:
180 -
181 -* Online – a flag of normal communication with the charger;
182 -* Voltage – voltage measured by the charger, V;
183 -* Actual current – current measured by the charger, A.
184 -
185 -=== CCS Fast charge controller ===
186 -
187 -Information about the status of communication with a CCS Fast charge controller is available in the "External equipment → Chargers → CCS Fast charge controller" section:
188 -
189 -[[image:1733403627284-333.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]]
190 -
191 -In this section:
192 -
193 -* CCS Controller online – a flag of normal communication with the charger;
194 -* Ovartech charger online;
195 -* BMS State;
196 -* CCS state machine;
197 -* Temperature of contactors DC, ºC;
198 -* Temperature of contactors AC, ºC;
199 -* Voltage – voltage measured by the charger, V;
200 -* Current – current measured by the charger, A;
201 -* Ovartech status.
202 -
203 203  === SMA Sunny Island inverter ===
204 204  
205 205  Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → SMA Sunny Island inverter " section:
... ... @@ -286,6 +286,36 @@
286 286  
287 287  Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value).
288 288  
259 +=== Skytronic charger ===
260 +
261 +Information about the status of communication with a Skytronic charger is available in the "External equipment → Chargers → Skytronic charger" section:
262 +
263 +[[image:1733403627283-582.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="78" width="800"]]
264 +
265 +In this section:
266 +
267 +* Online – a flag of normal communication with the charger;
268 +* Voltage – voltage measured by the charger, V;
269 +* Actual current – current measured by the charger, A.
270 +
271 +=== CCS Fast charge controller ===
272 +
273 +Information about the status of communication with a CCS Fast charge controller is available in the "External equipment → Chargers → CCS Fast charge controller" section:
274 +
275 +[[image:1733403627284-333.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]]
276 +
277 +In this section:
278 +
279 +* CCS Controller online – a flag of normal communication with the charger;
280 +* Ovartech charger online;
281 +* BMS State;
282 +* CCS state machine;
283 +* Temperature of contactors DC, ºC;
284 +* Temperature of contactors AC, ºC;
285 +* Voltage – voltage measured by the charger, V;
286 +* Current – current measured by the charger, A;
287 +* Ovartech status.
288 +
289 289  === Spirit AGV ===
290 290  
291 291  Information about the status of communication with a Spirit AGV is available in the "External equipment → Trucks and Vehicles → Spirit AGV" section: