Changes for page 4.5 External equipment

Last modified by Admin on 2024/12/26 16:33

From version 1.1
edited by Admin
on 2024/12/05 13:07
Change comment: There is no comment for this version
To version 1.4
edited by Admin
on 2024/12/26 16:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.bms-main-3.4\. Monitoring.WebHome
1 +Battery management systems.BMS Main 3.4\. Monitoring.WebHome
Content
... ... @@ -170,6 +170,36 @@
170 170  ** High temperature – charger is overheated;
171 171  ** Fault state – charger error.
172 172  
173 +=== Skytronic charger ===
174 +
175 +Information about the status of communication with a Skytronic charger is available in the "External equipment → Chargers → Skytronic charger" section:
176 +
177 +[[image:1733403627283-582.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="78" width="800"]]
178 +
179 +In this section:
180 +
181 +* Online – a flag of normal communication with the charger;
182 +* Voltage – voltage measured by the charger, V;
183 +* Actual current – current measured by the charger, A.
184 +
185 +=== CCS Fast charge controller ===
186 +
187 +Information about the status of communication with a CCS Fast charge controller is available in the "External equipment → Chargers → CCS Fast charge controller" section:
188 +
189 +[[image:1733403627284-333.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]]
190 +
191 +In this section:
192 +
193 +* CCS Controller online – a flag of normal communication with the charger;
194 +* Ovartech charger online;
195 +* BMS State;
196 +* CCS state machine;
197 +* Temperature of contactors DC, ºC;
198 +* Temperature of contactors AC, ºC;
199 +* Voltage – voltage measured by the charger, V;
200 +* Current – current measured by the charger, A;
201 +* Ovartech status.
202 +
173 173  === SMA Sunny Island inverter ===
174 174  
175 175  Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → SMA Sunny Island inverter " section:
... ... @@ -256,36 +256,6 @@
256 256  
257 257  Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value).
258 258  
259 -=== Skytronic charger ===
260 -
261 -Information about the status of communication with a Skytronic charger is available in the "External equipment → Chargers → Skytronic charger" section:
262 -
263 -[[image:1733403627283-582.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="78" width="800"]]
264 -
265 -In this section:
266 -
267 -* Online – a flag of normal communication with the charger;
268 -* Voltage – voltage measured by the charger, V;
269 -* Actual current – current measured by the charger, A.
270 -
271 -=== CCS Fast charge controller ===
272 -
273 -Information about the status of communication with a CCS Fast charge controller is available in the "External equipment → Chargers → CCS Fast charge controller" section:
274 -
275 -[[image:1733403627284-333.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]]
276 -
277 -In this section:
278 -
279 -* CCS Controller online – a flag of normal communication with the charger;
280 -* Ovartech charger online;
281 -* BMS State;
282 -* CCS state machine;
283 -* Temperature of contactors DC, ºC;
284 -* Temperature of contactors AC, ºC;
285 -* Voltage – voltage measured by the charger, V;
286 -* Current – current measured by the charger, A;
287 -* Ovartech status.
288 -
289 289  === Spirit AGV ===
290 290  
291 291  Information about the status of communication with a Spirit AGV is available in the "External equipment → Trucks and Vehicles → Spirit AGV" section: