Wiki source code of 4.5 External equipment

Last modified by Admin on 2024/12/26 16:33

Show last authors
1 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Monitoring =
3
4 (% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 == External equipment ==
6
7 Information about the status of external equipment is in the "External equipment" section.
8
9 === J1939 Charger ===
10
11 Information about the status of communication with a J1939 charger is available in the "External equipment → Chargers → J1939 charger" section:
12
13 [[image:1733403615335-586.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="800"]]
14
15 In this section:
16
17 * Online – a flag indicating if the connection with the charger is established;
18 * Voltage – a value of voltage received from the charger, V;
19 * Current – a value of current received from the charger, А.
20
21 === Eltek charger ===
22
23 Information about the status of communication with an Eltek charger is available in the "External equipment → Chargers → Eltek charger" section:
24
25 [[image:1733403615338-449.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="166" width="800"]]
26
27 In this section:
28
29 * Status:
30 ** Offline – no connection with charger;
31 ** No charge;
32 ** Charge;
33 ** Recoverable error;
34 ** Non-recoverable error;
35 * Input voltage, V;
36 * Input current, А;
37 * Input frequency, Hz;
38 * Output voltage, V;
39 * Output current, А;
40 * Primary temperature – temperature measured by the main temperature sensor, °C;
41 * Secondary temperature – temperature measured by an additional temperature sensor, °C;
42 * Max power – maximum power that the charger can provide, W;
43 * Available power, %;
44 * Errors – hexadecimal word with charger errors.
45
46 === MicroPower charger ===
47
48 Information about the status of communication with a MicroPower charger is available in the "External equipment → Chargers → MicroPower charger" section:
49
50 [[image:1733403615339-883.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="146" width="800"]]
51
52 In this section:
53
54 * Online – a flag of normal communication with the charger;
55 * Voltage, V;
56 * Current, A;
57 * Power, W;
58 * Charge information:
59 ** Voltage reached – output voltage of the charger is close to the required value;
60 ** Current reached – output current of the charger is close to the required value;
61 ** Power reached – output power of the charger is close to the required value;
62 * Limiter mode:
63 ** None;
64 ** Voltage;
65 ** Current;
66 ** Power;
67 ** Int. temperature – output is limited due to internal charger temperature;
68 ** Volt. boundary – bound voltage is reached;
69 ** Curr. boundary – bound current is reached;
70 ** Pow. boundary – bound power is reached;
71 ** DC limit;
72 ** AC limit;
73 ** Pow. AC limit – input power limitation;
74 ** Phase error;
75 * Cause of derate:
76 ** Phase error;
77 ** Parameters;
78 ** Poor power;
79 ** Internal temperature;
80 ** No load;
81 * Warnings, Errors:
82 ** Phase error;
83 ** Regulator error;
84 ** Low temperature;
85 ** High temperature;
86 ** Temperature protection;
87 ** CAN timeout.
88
89 === S.P.E. charger ===
90
91 Information about the status of communication with an S.P.E. charger is available in the "External equipment → Chargers → S.P.E. charger" section:
92
93 [[image:1733403615340-774.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="80" width="800"]]
94
95 In this section:
96
97 * Online – a flag of normal communication with the charger;
98 * Voltage, V;
99 * Current, A.
100
101 === Bassi charger ===
102
103 Information about the status of communication with a Bassi charger is available in the "External equipment → Chargers → Bassi charger" section:
104
105 [[image:1733403627269-810.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]]
106
107 In this section:
108
109 * Online – a flag of normal communication with the charger;
110 * Voltage – voltage measured by the charger, V;
111 * Current – current measured by the charger, A;
112 * Internal temperature – temperature of the charger, °C;
113 * Charge – energy which the charger transferred to the battery, Ah;
114 * Charging time – duration of the battery charging, minute.
115
116 === ATIB charger ===
117
118 Information about the status of communication with an ATIB charger is available in the "External equipment → Chargers → ATIB charger" section:
119
120 [[image:1733403627273-306.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="800"]]
121
122 In this section:
123
124 * Online – a flag of normal communication with the charger;
125 * Voltage – voltage measured by the charger, V;
126 * Current – current measured by the charger, A;
127 * Status – bitfield with status indicators:
128 ** Charger error;
129 ** High temperature;
130 ** Parameters out of limits;
131 ** Battery is not connected;
132 ** Communication error;
133 ** Thermal derating;
134 ** Precharge.
135
136 === Fronius charger ===
137
138 Information about the status of communication with a Fronius charger is available in the "External equipment → Chargers → Fronius charger" section:
139
140 [[image:1733403627280-868.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="800"]]
141
142 In this section:
143
144 * Online – a flag of normal communication with the charger;
145 * Voltage – voltage measured by the charger, V;
146 * Current – current measured by the charger, A;
147 * Status – bitfield with status indicators:
148 ** Power unit on – charger power status;
149 ** Voltage match finish – charging finished due to voltage achievement;
150 ** Delay;
151 ** Derating;
152 ** Error – charger error;
153 ** Break – charging stopped.
154
155 === Webasto charger ===
156
157 Information about the status of communication with a Webasto charger is available in the "External equipment → Chargers → Webasto charger" section:
158
159 [[image:1733403627282-942.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="800"]]
160
161 In this section:
162
163 * Online – a flag of normal communication with the charger;
164 * Voltage – voltage measured by the charger, V;
165 * Available current – maximum allowable charging current, A;
166 * Actual current – current measured by the charger, A;
167 * Status – bitfield with status indicators:
168 ** Ready to charge;
169 ** Charging – battery is charging;
170 ** High temperature – charger is overheated;
171 ** Fault state – charger error.
172
173 === Skytronic charger ===
174
175 Information about the status of communication with a Skytronic charger is available in the "External equipment → Chargers → Skytronic charger" section:
176
177 [[image:1733403627283-582.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="78" width="800"]]
178
179 In this section:
180
181 * Online – a flag of normal communication with the charger;
182 * Voltage – voltage measured by the charger, V;
183 * Actual current – current measured by the charger, A.
184
185 === CCS Fast charge controller ===
186
187 Information about the status of communication with a CCS Fast charge controller is available in the "External equipment → Chargers → CCS Fast charge controller" section:
188
189 [[image:1733403627284-333.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]]
190
191 In this section:
192
193 * CCS Controller online – a flag of normal communication with the charger;
194 * Ovartech charger online;
195 * BMS State;
196 * CCS state machine;
197 * Temperature of contactors DC, ºC;
198 * Temperature of contactors AC, ºC;
199 * Voltage – voltage measured by the charger, V;
200 * Current – current measured by the charger, A;
201 * Ovartech status.
202
203 === SMA Sunny Island inverter ===
204
205 Information about the status of communication with a SMA Sunny Island inverter is available in the "External equipment → Inverters → SMA Sunny Island inverter " section:
206
207 [[image:1733403635784-523.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="142" width="800"]]
208
209 In this section:
210
211 * Voltage, V.
212 * Current, A;
213 * Tempareture, °C;
214 * SOC, %;
215 * SOH, %;
216 * Mode – inverter working mode code;
217 * State – inverter state code;
218 * Error – inverter error code;
219 * Charging voltage, V.
220
221 === Pylontech inverter ===
222
223 Information about the status of communication with a Pylontech inverter is available in the "External equipment → Inverters → Pylontech inverter" section:
224
225 [[image:1733403635786-143.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="81" width="800"]]
226
227 In this section:
228
229 * Online – a flag of normal communication with the inverter;
230
231 === ASTOM load bank (cycling) ===
232
233 Information about the status of communication with a ASTOM load bank is available in the "External equipment → Inverters → ASTOM load bank (cycling)" section:
234
235 [[image:1733403635787-879.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]
236
237 In this section:
238
239 * Current state – current state of the cycle algorithm;
240 * Time elapsed, second;
241 * Number of completed cycles;
242 * Load bank online;
243 * Load current, A;
244 * Input voltage, V;
245 * Maximim DOD – maximum measured DOD during cycling, Ah;
246 * Logic index – BMS Logic identifier with fastest discharging cell connected;
247 * Cell index – number of fastest discharging cell;
248 * Start cycling – a trigger to start cycling.
249
250 === HYG Class I-III truck ===
251
252 Information about the status of communication with a HYG Class I-III truck is available in the "External equipment → Trucks and Vehicles → HYG Class I-III truck" section:
253
254 [[image:1733403635788-858.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]]
255
256 In this section:
257
258 * Online – a flag of normal communication with the forklift;
259 * Voltage, V;
260 * Current, А;
261 * Temperature, °C;
262 * Thermal derate, %;
263 * Control – bitfield with control commands transferred to the forklift:
264 ** Inhibit operation;
265 ** Immediate shutdown;
266 ** Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value);
267 ** Traction inhibit (Gen.2: charger connected);
268 ** Lift lockout – blocking of the lift (it is formed if the battery SOC is less than the “SOC: Lift lockout” value).
269
270 === Combilift truck ===
271
272 Information about the status of communication with a Combilift truck is available in the "External equipment → Trucks and Vehicles → Combilift truck" section:
273
274 [[image:1733403635788-647.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]]
275
276 In this section:
277
278 * Online – a flag of normal communication with equipment;
279 * Voltage, V;
280 * Current, А;
281 * Temperature, °C;
282 * Control – bitfield with control commands transferred to the forklift:
283 ** Power shutdown – turn off the forklift power;
284 ** Traction inhibit;
285 ** Lift lockout – blocking of the lift (it is formed if the battery SOC is less than the “SOC: Lift lockout” value);
286
287 Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value).
288
289 === Spirit AGV ===
290
291 Information about the status of communication with a Spirit AGV is available in the "External equipment → Trucks and Vehicles → Spirit AGV" section:
292
293 [[image:1733403652587-929.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="136" width="800"]]
294
295 In this section:
296
297 * Online – a flag of normal communication with the truck;
298 * Voltage, V;
299 * Current, A;
300 * Temperature, °C;
301 * Control 1 – first bitfield with control commands transferred to the forklift:
302 ** Inhibit operation;
303 ** Immediate shutdown;
304 ** Limited operation – mode of limited functionality (it is formed if the battery SOC is less than the “SOC: Limited operation” value);
305 ** Traction inhibit;
306 ** Lift lockout – blocking of the lift (it is formed if the battery SOC is less than the “SOC: Lift lockout” value).
307 * Control 2 – second bitfield with control commands transferred to the forklift:
308 ** Charger connected;
309 ** No charging or discharging current;
310 ** Charging;
311 ** Discharging;
312 ** Logic offline / Cell count error / Battery cover opened;
313 ** Overcurrent / Overvoltage / Undervoltage;
314 ** High temperature / Low temperature;
315 ** Board high temperature.
316 * Status – forklift status sent to BMS:
317 ** Shutdown immediately;
318 ** Confirmed shutdown;
319 ** Charging / not charging;
320 ** Charger critical error;
321 ** Charger non-critical error;
322 * Waiting time, second.
323
324 === Crown truck ===
325
326 Information about the status of communication with a Crown truck is available in the "External equipment → Trucks and Vehicles → Crown truck" section:
327
328 [[image:1733403652588-762.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="800"]]
329
330 In this section:
331
332 * Voltage A2 (from battery) – voltage measured by the BMS Crown on battery, V;
333 * Voltage A1 (from truck) – voltage produced by the Crown forklift system, V;
334 * Relay – command to power on the Crown forklift.
335
336 === ZiK truck ===
337
338 Information about the status of communication with a ZiK truck is available in the "External equipment → Trucks and Vehicles → ZiK truck" section:
339
340 [[image:1733403652588-674.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="165" width="800"]]
341
342 In this section:
343
344 * Battery voltage, V;
345 * Battery current, A;
346 * Supercapacitor voltage, V;
347 * Supercapacitor temperature, °C;
348 * Control – bitfield with control commands transferred to the forklift:
349 ** Discharging;
350 ** Allow discharging;
351 ** Charge supercapacitor;
352 ** Recuperation resistor;
353 ** Inhibit operation;
354 ** Undervoltage;
355 ** Overcurrent;
356 ** Limited operation.
357
358 === Evocargo Evo1.1 truck ===
359
360 Information about the status of communication with an Evocargo Evo1.1 truck is available in the "External equipment → Trucks and Vehicles → Evocargo Evo1.1 truck" section:
361
362 [[image:1733403652589-965.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="111" width="800"]]
363
364 In this section:
365
366 * Online – a flag of normal communication with the truck;
367 * Emulate control signals – a flag to emulate control signals;
368 * Emulation: Charge permission – a flag to emulate charge permission;
369 * Emulation Insulation control – a flag to emulate insulation control;
370 * Charge permission – state of “Charge permission” signal;
371 * Insulation control – state of “Insulation control” signal;
372
373 === BKM vehicle ===
374
375 Information about the status of communication with a BKM vehicle is available in the "External equipment → Trucks and Vehicles → BKM vehicle" section:
376
377 [[image:1733403652590-860.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="80" width="800"]]
378
379 In this section:
380
381 * Vehicle online – a flag of normal communication with the vehicle;
382 * Charger online – a flag of normal communication with the charger;
383
384 === Basic J1939 vehicle ===
385
386 Information about the status of communication with a vehicle via the J1939 protocol is available in the "External equipment → Trucks and Vehicles → Basic J1939 vehicle" section:
387
388 [[image:1733403652590-841.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]]
389
390 In this section:
391
392 * Online – a flag of normal communication with the vehicle;
393 * Maximum DOD – maximum allowed DOD of the battery, %.
394
395 === Bender iso165C ===
396
397 Information about the status of communication with Bender iso165C is available in the "External equipment → IMD → Bender iso165C" section:
398
399 [[image:1733403652591-578.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
400
401 In this section:
402
403 * Online – a flag of normal communication with the IMD;
404 * Configured – a flag indicating successful device set up;
405 * Status – device status;
406 * Insulation resistance – measured insulation resistance, Ohm.
407
408 === BMS IMD ===
409
410 Information about the status of communication with BMS IMD is available in the "External equipment → IMD → BMS IMD" section:
411
412 [[image:1733403652592-578.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="122" width="800"]]
413
414 In this section:
415
416 * Online – a flag of normal communication with the IMD;
417 * Configured – a flag indicating successful device set up;
418 * Insulation status;
419 * Internal errors – internal device errors;
420 * Device state – device status;
421 * Insulation resistance (plus) – measured insulation resistance between positive line and chassis, Ohm;
422 * Insulation resistance (minus) – measured insulation resistance between negative line and chassis, Ohm.
423
424 === Main X ===
425
426 Information about the status of communication with BMS Main X is available in the "External equipment → BMS → Main X" section:
427
428 [[image:1733403652592-229.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]]
429