Changes for page 4.2 Battery
Last modified by Admin on 2025/06/19 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,9 +21,9 @@ 21 21 * Number of Logic devices – number of connected Logic devices; 22 22 * Logic command rate – number of commands transmitted to Logic devices, com/s; 23 23 * Minimum Logic temperature – minimum temperature among Logic devices, °C; 24 -* Min.Logictemp.:Logic index– number of Logic with minimum temperature;24 +* # of Logic with minimum temperature – number of Logic with minimum temperature; 25 25 * Maximum Logic temperature – minimum temperature among Logic devices, °C; 26 -* Max.Logic temp.:Logicindex– number of Logic with maximum temperature;26 +* # of Logic with maximum temperature – number of Logic with maximum temperature; 27 27 * Number of cells – number of connected cells; 28 28 * Average cell temperature, °C; 29 29 * Minimum cell temperature, °C; ... ... @@ -33,17 +33,17 @@ 33 33 * Max. cell temp.: Logic index – number of Logic with maximum cell temperature; 34 34 * Max. cell temp.: cell index – number of cell with maximum temperature; 35 35 * Minimum cell voltage, V; 36 -* M in. cellvolt.: Logic index – number of Logic with minimum voltage;37 -* Min.cell volt.: cellindex– number of cell with minimum voltage;36 +* Max. cell temp.: Logic index – number of Logic with minimum voltage; 37 +* # of cell with minimum voltage – number of cell with minimum voltage; 38 38 * Maximum cell voltage, V; 39 -* Max.cell volt.: Logic index– number of Logic with maximum voltage;40 -* Max.cell volt.: cellindex– number of cell with maximum voltage;39 +* # of Logic with maximum cell voltage – number of Logic with maximum voltage; 40 +* # of cell with maximum voltage – number of cell with maximum voltage; 41 41 * Minimum cell SOC, %; 42 -* Min.cellSOC:Logic index– number of Logic with minimum SOC;43 -* Min.cellSOC:cell index– number of cell with minimum SOC;42 +* # of Logic with minimum cell SOC – number of Logic with minimum SOC; 43 +* # of cell with minimum SOC – number of cell with minimum SOC; 44 44 * Maximum cell SOC, %; 45 -* Max.cell SOC:Logic index– number of Logic with maximum SOC;46 -* Max.cellSOC:cell index – number of cell with maximum SOC;45 +* # of Logic with maximum cell SOC – number of Logic with maximum SOC; 46 +* # of cell with maximum SOC – number of cell with maximum SOC; 47 47 * Number of balancing cells; 48 48 * State: 49 49 ** Discharging ON; ... ... @@ -69,11 +69,98 @@ 69 69 * Work charge- - amount of charge transmitted to the load (negative direction) since device startup, Ah; 70 70 * Work energy+ - amount of energy received from charger (positive direction) since device startup, Wh; 71 71 * Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh; 72 -* Work energy regen - amount of regererated energy (positive direction) since device startup, Wh; 73 -* Total energy+ - total energy received by the battery modules from the charger, Wh; 72 +* Total energy+ - total energy received by the battery modules from the charger and during recuperation, Wh; 74 74 * Total energy- - total energy spent by the battery modules on the load, Wh; 75 -* Total energy regen - total energy received by the battery modules during recuperation, Wh; 76 76 * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh; 77 -* Input signals – a bitfield including input signals (see [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]); 78 -* Internal signals – a bitfield including device internal signals (see [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]); 79 -* Errors 1, 2 – errors of the battery (see see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]). 75 +* Input singals: 76 +** Battery cover – a signal from the battery cover; 77 +** Charger connected – a signal indicating that charger is connected; 78 +** Power up/down request – a request to power down the device; 79 +** Inhibit charging – a command to open the charging contactor; 80 +** Inhibit discharging – a command to open the discharging contactor; 81 +** CH contactor feedback – a signal from charging contactor feedback loop; 82 +** DCH contactor feedback – a signal from discharging contactor feedback loop; 83 +** Insulation status – a signal from an insulation monitoring device; 84 +** Charge request – a request to close the charging contactor; 85 +** Precharge request – a request to close the precharging contactor; 86 +** Discharge request – a request to close the discharging contactor; 87 +** PCH contactor feedback – a signal from precharging contactor feedback loop; 88 +** CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 89 +** Main contactor feedback – a signal from main contactor feedback loop; 90 +** Interlock – a signal from interlock loop; 91 +** Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 92 +** Circuit breaker status – status of protection disconnector; 93 +** Balancing request – a request to balance the cells; 94 +** Close Main contactor – a request to close the main contactor. 95 +* Internal signals – device internal signals: 96 +** Low SOC – a signal indicating the discharged battery; 97 +** High charging current; 98 +** Charging – state of the charging contactor; 99 +** Allow charging signal – signal allowing the operation of the charger; 100 +** Charging current present – charging current is detected; 101 +** Discharging – state of the discharging contactor; 102 +** Discharging current present – discharging current is detected; 103 +** Voltage is too high for charging; 104 +** Heater – signal to turn on heater; 105 +** Cooler – signal to turn on cooler; 106 +** Shutdown request (HYG/Spirit) – request to open the discharging contactor received from the HYG forklift; 107 +** Init – initialization of the device (calibration of the current sensor and searching BMS Logic devices); 108 +** Precharging – state of the precharging contactor; 109 +** Shutdown request (Combilift) – request to open the discharging contactor received from the Combilift forklift; 110 +** Cell analysis – operation of the algorithm for determining the discharge characteristics; 111 +** Balancing 1 – balancing the first series of cells; 112 +** Balancing 2 – balancing the second series of cells; 113 +** Discharging (AUX) – state of the discharging (AUX) contactor (powering of external equipment is on); 114 +** Power down ACK – signal to acknowledge powering down the battery system; 115 +** Crown EWS – signal sent to the Crown truck before opening the discharging contactor; 116 +** Main contactor – state of the main contactor; 117 +** Service reset; 118 +** Charging/Discharging – state of the charging/discharging contactor; 119 +** Ready to charge – the battery is ready to charge; 120 +** Ready to discharge – the battery is ready to discharge; 121 +** Power up – system power status; 122 +* Errors 1 – errors of the battery 1: 123 +** Overcurrent; 124 +** Undervoltage; 125 +** Overvoltage; 126 +** Low temperature (DCH) – temperature is too low for discharging; 127 +** High temperature (DCH) – temperature is too high for discharging; 128 +** Battery cover error – battery cover is open; 129 +** High humidity – humidity of the battery is increased; 130 +** Water – there is water in the battery enclosure; 131 +** High Logic temperature – at least one of the Logic devices is overheated; 132 +** Logic offline – at least one of the Logic devices is offline; 133 +** Critical error; 134 +** Crown error – connection with a Crown forklift is lost; 135 +** Cell count error – number of cells does not match the specified value; 136 +** HYG offline – connection with a HYG forklift is lost; 137 +** Combilift offline – connection with a Combilift forklift is lost; 138 +** Short circuit; 139 +** High contactor temperature; 140 +** ADC error – current cannot be measured; 141 +** Current sensor error – error in the current sensor circuit; 142 +** CH contactor cycles error – switching frequency of the charging contactor is too high; 143 +** DCH contactor cycles error – switching frequency of the discharging contactor is too high; 144 +** Shunt offline – connection with the shunt current sensor is lost; 145 +** Shunt error – internal error of the shunt current sensor; 146 +** WDT reset – watchdog timer reset the device; 147 +** No temperature sensors – the device has no temperature sensors connected; 148 +** Temperature sensor is shorted – some temperature sensors are shorted; 149 +** Spirit offline – connection with a Spirit forklift is lost; 150 +* Errors 2 – errors of the battery 2: 151 +** Low temperature (CH) – temperature is too low for charging; 152 +** High temperature (CH) – temperature is too high for charging; 153 +** Unallowable charging – charging the battery through the discharging contactor; 154 +** Stuck contactor; 155 +** CH contactor feedback error – the control signals for the charging contactor and the contactor feedback differ; 156 +** DCH contactor feedback error – the control signals for the discharging contactor and the contactor feedback differ; 157 +** Insulation fault; 158 +** PCH contactor feedback error – the control signals for the precharging contactor and the contactor feedback differ; 159 +** CH/DCH contactor feedback error – the control signals for the charging/discharging contactor and the contactor feedback differ; 160 +** Main contactor feedback error – the control signals for the main contactor and the contactor feedback differ; 161 +** General error; 162 +** High voltage fault – failure of high voltage measuring circuits; 163 +** Power switch error – short circuit in contactor coil control circuit or power switch overheating; 164 +** HVIL error – breakage of high-voltage interlock current loop; 165 +** Precharge error – capacitive load pre-charge process did not end during the estimated time; 166 +** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices.