4.1 Signals

Version 2.3 by Admin on 2024/12/11 11:33

Monitoring

Signals

States of the device's discrete inputs are available in the "Signals → Input discrete signal" section:

1733402780551-891.png

In this section:

  • Battery cover – a signal from the battery cover;
  • Charger connected – a signal indicating that charger is connected;
  • Power up/down request – a request to power down the device;
  • Inhibit charging – a command to open the charging contactor;
  • Inhibit discharging – a command to open the discharging contactor;
  • CH contactor feedback – a signal from charging contactor feedback loop;
  • DCH contactor feedback – a signal from discharging contactor feedback loop;
  • Insulation status – a signal from an insulation monitoring device;
  • Charge request – a request to close the charging contactor;
  • Precharge request – a request to close the precharging contactor;
  • Discharge request – a request to close the discharging contactor;
  • PCH contactor feedback – a signal from precharging contactor feedback loop;
  • CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
  • Main contactor feedback – a signal from main contactor feedback loop;
  • Interlock – a signal from interlock loop;
  • Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
  • Circuit breaker status – status of protection disconnector;
  • Balancing request – a request to balance the cells;
  • Close Main contactor – a request to close the main contactor.

The states of the discrete output signals are available in the "Signals → Output discrete signals" section:

1733402780555-886.png

In this section:

  • Output #1 - Output #4 – states of the outputs 1-4 respectively.

The states of the power switches are available in the "Signals → Power switches" section:

1733402780556-463.png

In this section:

  • Power switch #1 - Power switch #6 – states of the Power switches 1-6 respectively.

Current sensor

The states of the current sensors are available in the "Signals → Current sensor" section:

1733402780557-330.png

In this section:

  • Sensor 1, 2, 3: IN1 – output signal from the current sensor, V;
  • Sensor 1, 2, 3: REF_IN2 – signal in the reference line, V;
  • Sensor 1, 2, 3: Value – calculated value of the current, A;
  • Sensor 1, 2, 3: Low range – calculated value of the lower range current, A.

Shunt sensor

The state of the shunt sensor is available in the "Signals → Shunt sensor" section:

1733402780565-376.png

In this section:

  • Online – a flag showing that the communication with the BMS Current Sensor is established;
  • Errors – a list of internal errors of the shunt sensor;
  • Current – an instantaneous value of current measured by the BMS Current Sensor, A (measuring frequency is 50 Hz);
  • Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements);
  • Temperature – a temperature of the shunt sensor, °C.

HVIL

The state of the HVIL is available in the "Signals → HVIL" section:

1733402780566-996.png

In this section:

  • Current (power off) – high voltage interlock loop current at power off, A;
  • Current (power on) – high voltage interlock loop current at power on, A.