Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -42,14 +42,6 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 -=== Charge current limit === 46 - 47 -TBA 48 - 49 -=== Discharge current limit === 50 - 51 -TBA 52 - 53 53 === Undervoltage === 54 54 55 55 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -56,7 +56,7 @@ 56 56 57 57 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 58 58 59 -[[image:173 5224224155-829.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]51 +[[image:1733328382380-760.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]] 60 60 61 61 In this section: 62 62 ... ... @@ -63,7 +63,6 @@ 63 63 * Enable – a flag to enable the protection; 64 64 * Minimum cell voltage, V; 65 65 * Tolerant cell voltage, V; 66 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 67 67 * Delay before setting the error, millisecond; 68 68 * Delay before clearing the error, second; 69 69 * Lock – a flag to block the error until the device is restarted. ... ... @@ -89,7 +89,7 @@ 89 89 90 90 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 91 91 92 -[[image:173 5224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]]83 +[[image:1733328382382-607.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 93 93 94 94 In this section: 95 95 ... ... @@ -96,9 +96,9 @@ 96 96 * Enable – a flag to enable the protection; 97 97 * Maximum cell voltage, V; 98 98 * Tolerant cell voltage, V; 99 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 100 100 * Delay before setting the error, millisecond; 101 101 * Delay before clearing the error, second; 92 +* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 102 102 * Lock – a flag to block the error until the device is restarted. 103 103 104 104 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -278,7 +278,7 @@ 278 278 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 279 279 ))) 280 280 281 -=== Logic hightemperature ===272 +=== High Logic temperature === 282 282 283 283 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 284 284 ... ... @@ -512,10 +512,6 @@ 512 512 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 513 513 ))) 514 514 515 -=== Power fault === 516 - 517 -TBA 518 - 519 519 === Charge contactor cycles === 520 520 521 521 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -705,6 +705,28 @@ 705 705 If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 706 706 ))) 707 707 695 +=== Precharge === 696 + 697 +BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. To change the pre-charge monitoring parameters, select the "Protections → Precharge" section: 698 + 699 +[[image:1733328487097-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="99" width="800"]] 700 + 701 +In this section: 702 + 703 +* Enable – a flag to enable the protection; 704 +* Delay before setting the error, millisecond; 705 +* Delay before clearing the error, second; 706 +* Lock – a flag to block the error until the device is restarted. 707 + 708 +As a result of the protection algorithms the “Precharge error” is generated. Error generation conditions: 709 + 710 +* precharging process cannot be finished (the precharge current does not decrease or voltages before and after contactors are not equal) during the “Delay before setting the error” time. 711 + 712 +(% class="box infomessage" %) 713 +((( 714 +If there is the “Precharge error”, **charging **and **discharging **contactors open. 715 +))) 716 + 708 708 === Insulation === 709 709 710 710 The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. ... ... @@ -796,7 +796,7 @@ 796 796 If there is the “Critical error”, **all **contactors open. 797 797 ))) 798 798 799 -=== General error === 808 +=== General error === 800 800 801 801 To change the general error parameters, select the "Protections → Critical error" section: 802 802
- 1735224224155-829.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.4 KB - Content
- 1735224377252-473.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.4 KB - Content