... ... @@ -63,7 +63,7 @@
63 63  * Enable – a flag to enable the protection;
64 64  * Minimum cell voltage, V;
65 65  * Tolerant cell voltage, V;
66 -* Check the open circuit voltage instead of the actual voltage a flag to enable the check of voltage correction due to current and cell resistance;
66 +* Check the open circuit voltage instead of the actual voltage a flag to enable the protection;;
67 67  * Delay before setting the error, millisecond;
68 68  * Delay before clearing the error, second;
69 69  * Lock – a flag to block the error until the device is restarted.
... ... @@ -96,7 +96,6 @@
96 96  * Enable – a flag to enable the protection;
97 97  * Maximum cell voltage, V;
98 98  * Tolerant cell voltage, V;
99 -* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
100 100  * Delay before setting the error, millisecond;
101 101  * Delay before clearing the error, second;
102 102  * Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated;