Summary

Details

Page properties
Content
... ... @@ -12,7 +12,7 @@
12 12  
13 13  To change the overcurrent protection of the battery, select the "Protections → Overcurrent" section:
14 14  
15 -[[image:1733328382376-958.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
15 +[[image:1735224601506-488.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]]
16 16  
17 17  In this section:
18 18  
... ... @@ -89,7 +89,7 @@
89 89  
90 90  To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section:
91 91  
92 -[[image:1733328382382-607.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
92 +[[image:1735224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]]
93 93  
94 94  In this section:
95 95  
... ... @@ -99,7 +99,6 @@
99 99  * Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
100 100  * Delay before setting the error, millisecond;
101 101  * Delay before clearing the error, second;
102 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated;
103 103  * Lock – a flag to block the error until the device is restarted.
104 104  
105 105  As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated.
... ... @@ -398,7 +398,7 @@
398 398  
399 399  To change the protection parameters from short circuit, select the "Protections → Short circuit" section:
400 400  
401 -[[image:1733328415733-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="210" width="800"]]
400 +[[image:1735224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]]
402 402  
403 403  In this section:
404 404  
... ... @@ -406,8 +406,6 @@
406 406  ** Enable – a flag to enable the protection;
407 407  ** Maximum current, A;
408 408  ** Delay before setting the error, second;
409 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs;
410 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs;
411 411  * Delay before clearing the error, second;
412 412  * Lock – a flag to block the error until the device is restarted.
413 413  
... ... @@ -432,7 +432,7 @@
432 432  
433 433  To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section:
434 434  
435 -[[image:1733328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
432 +[[image:1735224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]
436 436  
437 437  In this section:
438 438  
... ... @@ -441,8 +441,6 @@
441 441  * Maximum contactor temperature, °C;
442 442  * Tolerant contactor temperature, °C;
443 443  * Delay before setting the error, second;
444 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs;
445 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs;
446 446  * Delay before clearing the error, second;
447 447  * Lock – a flag to block the error until the device is restarted.
448 448  
... ... @@ -738,14 +738,18 @@
738 738  
739 739  To change the HVIL measurement parameters, select the "Protections → HVIL" section:
740 740  
741 -[[image:1733328487099-371.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]
736 +[[image:1735224839441-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
742 742  
743 743  In this section:
744 744  
745 745  * Enable – a flag to enable the protection;
741 +* Source is OFF: Lower current limit, A;
742 +* Source is OFF: Upper current limit, A;
743 +* Source is ON: Lower current limit, A;
744 +* Source is ON: Upper current limit, A;
746 746  * Lock – a flag to block the error until the device is restarted.
747 747  
748 -If interlock loop breaks, the “HVIL error” is generated. Error clears if interlock loop is being restored.
747 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored.
749 749  
750 750  (% class="box warningmessage" %)
751 751  (((
... ... @@ -801,7 +801,7 @@
801 801  
802 802  To change the general error parameters, select the "Protections → Critical error" section:
803 803  
804 -[[image:1733328487101-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]
803 +[[image:1735224942262-497.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]]
805 805  
806 806  In this section:
807 807  
... ... @@ -809,7 +809,7 @@
809 809  * Delay before setting the error, millisecond;
810 810  * Delay before clearing the error, second;
811 811  * Lock – a flag to block the error until the device is restarted;
812 -* Check: <error> – a flags to enable check of corresponding errors.
811 +* Errors 1, 2 to ser – a flags to enable check of corresponding errors.
813 813  
814 814  The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time.
815 815  
1735224601506-488.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content
1735224667621-969.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +32.8 KB
Content
1735224706573-347.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +22.1 KB
Content
1735224839441-185.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +20.1 KB
Content
1735224942262-497.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content