Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,7 +12,7 @@ 12 12 13 13 To change the overcurrent protection of the battery, select the "Protections → Overcurrent" section: 14 14 15 -[[image:173 3328382376-958.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]15 +[[image:1735224601506-488.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 16 16 17 17 In this section: 18 18 ... ... @@ -89,7 +89,7 @@ 89 89 90 90 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 91 91 92 -[[image:173 3328382382-607.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]92 +[[image:1735224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]] 93 93 94 94 In this section: 95 95 ... ... @@ -99,7 +99,6 @@ 99 99 * Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 100 100 * Delay before setting the error, millisecond; 101 101 * Delay before clearing the error, second; 102 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 103 103 * Lock – a flag to block the error until the device is restarted. 104 104 105 105 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -398,7 +398,7 @@ 398 398 399 399 To change the protection parameters from short circuit, select the "Protections → Short circuit" section: 400 400 401 -[[image:173 3328415733-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="210" width="800"]]400 +[[image:1735224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]] 402 402 403 403 In this section: 404 404 ... ... @@ -406,8 +406,6 @@ 406 406 ** Enable – a flag to enable the protection; 407 407 ** Maximum current, A; 408 408 ** Delay before setting the error, second; 409 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs; 410 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs; 411 411 * Delay before clearing the error, second; 412 412 * Lock – a flag to block the error until the device is restarted. 413 413 ... ... @@ -432,7 +432,7 @@ 432 432 433 433 To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section: 434 434 435 -[[image:173 3328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]432 +[[image:1735224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] 436 436 437 437 In this section: 438 438 ... ... @@ -441,8 +441,6 @@ 441 441 * Maximum contactor temperature, °C; 442 442 * Tolerant contactor temperature, °C; 443 443 * Delay before setting the error, second; 444 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs; 445 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs; 446 446 * Delay before clearing the error, second; 447 447 * Lock – a flag to block the error until the device is restarted. 448 448 ... ... @@ -738,14 +738,18 @@ 738 738 739 739 To change the HVIL measurement parameters, select the "Protections → HVIL" section: 740 740 741 -[[image:173 3328487099-371.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]736 +[[image:1735224839441-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] 742 742 743 743 In this section: 744 744 745 745 * Enable – a flag to enable the protection; 741 +* Source is OFF: Lower current limit, A; 742 +* Source is OFF: Upper current limit, A; 743 +* Source is ON: Lower current limit, A; 744 +* Source is ON: Upper current limit, A; 746 746 * Lock – a flag to block the error until the device is restarted. 747 747 748 -If interlock loop breaks, the “HVIL error” is generated. Error clears if interlock loop is being restored. 747 +If interlock loop breaks and its curre, the “HVIL error” is generated. Error clears if interlock loop is being restored. 749 749 750 750 (% class="box warningmessage" %) 751 751 (((
- 1735224601506-488.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- 1735224667621-969.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.8 KB - Content
- 1735224706573-347.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.1 KB - Content
- 1735224839441-185.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.1 KB - Content