Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Battery management systems.BMS Main 3.3\. Configuration.WebHome1 +Battery management systems.BMS Main 3.3\. Settings.WebHome - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration =2 += Settings = 3 3 4 4 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Protections == ... ... @@ -42,14 +42,6 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 -=== Charge current limit === 46 - 47 -TBA 48 - 49 -=== Discharge current limit === 50 - 51 -TBA 52 - 53 53 === Undervoltage === 54 54 55 55 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -56,7 +56,7 @@ 56 56 57 57 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 58 58 59 -[[image:173 5224224155-829.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]51 +[[image:1733328382380-760.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]] 60 60 61 61 In this section: 62 62 ... ... @@ -63,7 +63,6 @@ 63 63 * Enable – a flag to enable the protection; 64 64 * Minimum cell voltage, V; 65 65 * Tolerant cell voltage, V; 66 -* Check the open circuit voltage instead of the actual voltage a flag to enable the protection;; 67 67 * Delay before setting the error, millisecond; 68 68 * Delay before clearing the error, second; 69 69 * Lock – a flag to block the error until the device is restarted. ... ... @@ -278,7 +278,7 @@ 278 278 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 279 279 ))) 280 280 281 -=== Logic hightemperature ===272 +=== High Logic temperature === 282 282 283 283 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 284 284 ... ... @@ -512,10 +512,6 @@ 512 512 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 513 513 ))) 514 514 515 -=== Power fault === 516 - 517 -TBA 518 - 519 519 === Charge contactor cycles === 520 520 521 521 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -655,7 +655,7 @@ 655 655 If there is the "Unallowable charging" error, the **discharging **contactor opens. 656 656 ))) 657 657 658 -=== Stuck contactor === 645 +=== Stuck contactor === 659 659 660 660 The BMS Main 3 device protects contactors against sticking. 661 661 ... ... @@ -705,8 +705,30 @@ 705 705 If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 706 706 ))) 707 707 708 -=== Insulation===695 +=== Precharge === 709 709 697 +BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. To change the pre-charge monitoring parameters, select the "Protections → Precharge" section: 698 + 699 +[[image:1733328487097-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="99" width="800"]] 700 + 701 +In this section: 702 + 703 +* Enable – a flag to enable the protection; 704 +* Delay before setting the error, millisecond; 705 +* Delay before clearing the error, second; 706 +* Lock – a flag to block the error until the device is restarted. 707 + 708 +As a result of the protection algorithms the “Precharge error” is generated. Error generation conditions: 709 + 710 +* precharging process cannot be finished (the precharge current does not decrease or voltages before and after contactors are not equal) during the “Delay before setting the error” time. 711 + 712 +(% class="box infomessage" %) 713 +((( 714 +If there is the “Precharge error”, **charging **and **discharging **contactors open. 715 +))) 716 + 717 +=== Insulation === 718 + 710 710 The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. 711 711 712 712 To change the insulation monitoring parameters, select the "Protections → Insulation" section: ... ... @@ -796,7 +796,7 @@ 796 796 If there is the “Critical error”, **all **contactors open. 797 797 ))) 798 798 799 -=== General error === 808 +=== General error === 800 800 801 801 To change the general error parameters, select the "Protections → Critical error" section: 802 802
- 1735224224155-829.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.4 KB - Content