Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,7 +12,7 @@ 12 12 13 13 To change the overcurrent protection of the battery, select the "Protections → Overcurrent" section: 14 14 15 -[[image:173 3328382376-958.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]15 +[[image:1735224601506-488.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 16 16 17 17 In this section: 18 18 ... ... @@ -63,7 +63,7 @@ 63 63 * Enable – a flag to enable the protection; 64 64 * Minimum cell voltage, V; 65 65 * Tolerant cell voltage, V; 66 -* Check the open circuit voltage instead of the actual voltage a flag to enable the protection;;66 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 67 67 * Delay before setting the error, millisecond; 68 68 * Delay before clearing the error, second; 69 69 * Lock – a flag to block the error until the device is restarted. ... ... @@ -89,7 +89,7 @@ 89 89 90 90 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 91 91 92 -[[image:173 3328382382-607.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]92 +[[image:1735224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]] 93 93 94 94 In this section: 95 95 ... ... @@ -96,9 +96,9 @@ 96 96 * Enable – a flag to enable the protection; 97 97 * Maximum cell voltage, V; 98 98 * Tolerant cell voltage, V; 99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 99 99 * Delay before setting the error, millisecond; 100 100 * Delay before clearing the error, second; 101 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 102 102 * Lock – a flag to block the error until the device is restarted. 103 103 104 104 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -397,7 +397,7 @@ 397 397 398 398 To change the protection parameters from short circuit, select the "Protections → Short circuit" section: 399 399 400 -[[image:173 3328415733-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="210" width="800"]]400 +[[image:1735224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]] 401 401 402 402 In this section: 403 403 ... ... @@ -405,8 +405,6 @@ 405 405 ** Enable – a flag to enable the protection; 406 406 ** Maximum current, A; 407 407 ** Delay before setting the error, second; 408 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs; 409 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs; 410 410 * Delay before clearing the error, second; 411 411 * Lock – a flag to block the error until the device is restarted. 412 412 ... ... @@ -431,7 +431,7 @@ 431 431 432 432 To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section: 433 433 434 -[[image:173 3328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]432 +[[image:1735224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] 435 435 436 436 In this section: 437 437 ... ... @@ -440,8 +440,6 @@ 440 440 * Maximum contactor temperature, °C; 441 441 * Tolerant contactor temperature, °C; 442 442 * Delay before setting the error, second; 443 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs; 444 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs; 445 445 * Delay before clearing the error, second; 446 446 * Lock – a flag to block the error until the device is restarted. 447 447
- 1735224377252-473.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1735224601506-488.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- 1735224667621-969.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.8 KB - Content
- 1735224706573-347.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.1 KB - Content