Changes for page 3.4 Protections

Last modified by Admin on 2025/04/09 12:19

From version 8.1
edited by Admin
on 2024/12/26 14:43
Change comment: Uploaded new attachment "1735224224155-829.png", version {1}
To version 10.1
edited by Admin
on 2024/12/26 14:50
Change comment: Uploaded new attachment "1735224601506-488.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -56,7 +56,7 @@
56 56  
57 57  To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section:
58 58  
59 -[[image:1733328382380-760.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]
59 +[[image:1735224224155-829.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]
60 60  
61 61  In this section:
62 62  
... ... @@ -63,6 +63,7 @@
63 63  * Enable – a flag to enable the protection;
64 64  * Minimum cell voltage, V;
65 65  * Tolerant cell voltage, V;
66 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
66 66  * Delay before setting the error, millisecond;
67 67  * Delay before clearing the error, second;
68 68  * Lock – a flag to block the error until the device is restarted.
... ... @@ -88,7 +88,7 @@
88 88  
89 89  To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section:
90 90  
91 -[[image:1733328382382-607.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
92 +[[image:1735224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]]
92 92  
93 93  In this section:
94 94  
... ... @@ -95,9 +95,9 @@
95 95  * Enable – a flag to enable the protection;
96 96  * Maximum cell voltage, V;
97 97  * Tolerant cell voltage, V;
99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance;
98 98  * Delay before setting the error, millisecond;
99 99  * Delay before clearing the error, second;
100 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated;
101 101  * Lock – a flag to block the error until the device is restarted.
102 102  
103 103  As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated.
1735224377252-473.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.4 KB
Content
1735224601506-488.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content