Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -42,14 +42,6 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 -=== Charge current limit === 46 - 47 -TBA 48 - 49 -=== Discharge current limit === 50 - 51 -TBA 52 - 53 53 === Undervoltage === 54 54 55 55 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -277,7 +277,7 @@ 277 277 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 278 278 ))) 279 279 280 -=== Logic hightemperature ===272 +=== High Logic temperature === 281 281 282 282 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 283 283 ... ... @@ -511,10 +511,6 @@ 511 511 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 512 512 ))) 513 513 514 -=== Power fault === 515 - 516 -TBA 517 - 518 518 === Charge contactor cycles === 519 519 520 520 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -704,6 +704,28 @@ 704 704 If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 705 705 ))) 706 706 695 +=== Precharge === 696 + 697 +BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. To change the pre-charge monitoring parameters, select the "Protections → Precharge" section: 698 + 699 +[[image:1733328487097-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="99" width="800"]] 700 + 701 +In this section: 702 + 703 +* Enable – a flag to enable the protection; 704 +* Delay before setting the error, millisecond; 705 +* Delay before clearing the error, second; 706 +* Lock – a flag to block the error until the device is restarted. 707 + 708 +As a result of the protection algorithms the “Precharge error” is generated. Error generation conditions: 709 + 710 +* precharging process cannot be finished (the precharge current does not decrease or voltages before and after contactors are not equal) during the “Delay before setting the error” time. 711 + 712 +(% class="box infomessage" %) 713 +((( 714 +If there is the “Precharge error”, **charging **and **discharging **contactors open. 715 +))) 716 + 707 707 === Insulation === 708 708 709 709 The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. ... ... @@ -795,7 +795,7 @@ 795 795 If there is the “Critical error”, **all **contactors open. 796 796 ))) 797 797 798 -=== General error === 808 +=== General error === 799 799 800 800 To change the general error parameters, select the "Protections → Critical error" section: 801 801