Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration =2 += Settings = 3 3 4 4 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Protections == ... ... @@ -42,14 +42,6 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 -=== Charge current limit === 46 - 47 -TBA 48 - 49 -=== Discharge current limit === 50 - 51 -TBA 52 - 53 53 === Undervoltage === 54 54 55 55 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -277,7 +277,7 @@ 277 277 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 278 278 ))) 279 279 280 -=== Logic hightemperature ===272 +=== High Logic temperature === 281 281 282 282 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 283 283 ... ... @@ -511,10 +511,6 @@ 511 511 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 512 512 ))) 513 513 514 -=== Power fault === 515 - 516 -TBA 517 - 518 518 === Charge contactor cycles === 519 519 520 520 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -654,7 +654,7 @@ 654 654 If there is the "Unallowable charging" error, the **discharging **contactor opens. 655 655 ))) 656 656 657 -=== Stuck contactor === 645 +=== Stuck contactor === 658 658 659 659 The BMS Main 3 device protects contactors against sticking. 660 660 ... ... @@ -704,8 +704,30 @@ 704 704 If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 705 705 ))) 706 706 707 -=== Insulation===695 +=== Precharge === 708 708 697 +BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. To change the pre-charge monitoring parameters, select the "Protections → Precharge" section: 698 + 699 +[[image:1733328487097-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="99" width="800"]] 700 + 701 +In this section: 702 + 703 +* Enable – a flag to enable the protection; 704 +* Delay before setting the error, millisecond; 705 +* Delay before clearing the error, second; 706 +* Lock – a flag to block the error until the device is restarted. 707 + 708 +As a result of the protection algorithms the “Precharge error” is generated. Error generation conditions: 709 + 710 +* precharging process cannot be finished (the precharge current does not decrease or voltages before and after contactors are not equal) during the “Delay before setting the error” time. 711 + 712 +(% class="box infomessage" %) 713 +((( 714 +If there is the “Precharge error”, **charging **and **discharging **contactors open. 715 +))) 716 + 717 +=== Insulation === 718 + 709 709 The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. 710 710 711 711 To change the insulation monitoring parameters, select the "Protections → Insulation" section: ... ... @@ -795,7 +795,7 @@ 795 795 If there is the “Critical error”, **all **contactors open. 796 796 ))) 797 797 798 -=== General error === 808 +=== General error === 799 799 800 800 To change the general error parameters, select the "Protections → Critical error" section: 801 801