Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS MainConfiguration.WebHome1 +drafts.bms-main-3.3\. Settings.WebHome - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration =2 += SettingsThe BMS Main 3 device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage.The BMS Main 3 device continuously monitors the state of the cells, the external environment and, when detecting abnormalities, protects the battery and system components from damage. = 3 3 4 4 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Protections == ... ... @@ -42,14 +42,6 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 -=== Charge current limit === 46 - 47 -TBA 48 - 49 -=== Discharge current limit === 50 - 51 -TBA 52 - 53 53 === Undervoltage === 54 54 55 55 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -302,9 +302,9 @@ 302 302 303 303 * a BMS Logic device temperature is less than the “Tolerant temperature” value. 304 304 305 -(% class="box in fomessage" %)297 +(% class="box warningmessage" %) 306 306 ((( 307 - Cell balancing is disabledonLogic deviceswithhightemperature.299 +Overheated Logic devices do not balance cells. 308 308 ))) 309 309 310 310 === Logic offline === ... ... @@ -543,7 +543,7 @@ 543 543 If there is the "CH contactor cycles error" error, the **charging **contactor opens. 544 544 ))) 545 545 546 -=== Discharge contactor cycles === 538 +=== Discharge contactor cycles === 547 547 548 548 The BMS Main 3 device protects the discharging contactor against frequent switching. 549 549 ... ... @@ -594,7 +594,7 @@ 594 594 595 595 (% class="box warningmessage" %) 596 596 ((( 597 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 589 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 598 598 ))) 599 599 600 600 === WDT reset === ... ... @@ -620,7 +620,7 @@ 620 620 If there is the "WDT reset" error, the **“Critical error” **is generated and **all relays open.** 621 621 ))) 622 622 623 -=== Unallowable charging === 615 +=== Unallowable charging === 624 624 625 625 The BMS can detect that the battery is charging through the discharging circuit and protectively open the discharging contactor to prevent unallowable battery operation. 626 626 ... ... @@ -650,7 +650,7 @@ 650 650 If there is the "Unallowable charging" error, the **discharging **contactor opens. 651 651 ))) 652 652 653 -=== Stuck contactor === 645 +=== Stuck contactor === 654 654 655 655 The BMS Main 3 device protects contactors against sticking. 656 656 ... ... @@ -700,8 +700,30 @@ 700 700 If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 701 701 ))) 702 702 703 -=== Insulation===695 +=== Precharge === 704 704 697 +BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. To change the pre-charge monitoring parameters, select the "Protections → Precharge" section: 698 + 699 +[[image:1733328487097-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="99" width="800"]] 700 + 701 +In this section: 702 + 703 +* Enable – a flag to enable the protection; 704 +* Delay before setting the error, millisecond; 705 +* Delay before clearing the error, second; 706 +* Lock – a flag to block the error until the device is restarted. 707 + 708 +As a result of the protection algorithms the “Precharge error” is generated. Error generation conditions: 709 + 710 +* precharging process cannot be finished (the precharge current does not decrease or voltages before and after contactors are not equal) during the “Delay before setting the error” time. 711 + 712 +(% class="box infomessage" %) 713 +((( 714 +If there is the “Precharge error”, **charging **and **discharging **contactors open. 715 +))) 716 + 717 +=== Insulation === 718 + 705 705 The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. 706 706 707 707 To change the insulation monitoring parameters, select the "Protections → Insulation" section: ... ... @@ -791,7 +791,7 @@ 791 791 If there is the “Critical error”, **all **contactors open. 792 792 ))) 793 793 794 -=== General error === 808 +=== General error === 795 795 796 796 To change the general error parameters, select the "Protections → Critical error" section: 797 797