Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,7 +12,7 @@ 12 12 13 13 To change the overcurrent protection of the battery, select the "Protections → Overcurrent" section: 14 14 15 -[[image:173 3328382376-958.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]15 +[[image:1735224601506-488.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 16 16 17 17 In this section: 18 18 ... ... @@ -44,9 +44,11 @@ 44 44 45 45 === Charge current limit === 46 46 47 +TBA 47 47 48 48 === Discharge current limit === 49 49 51 +TBA 50 50 51 51 === Undervoltage === 52 52 ... ... @@ -54,7 +54,7 @@ 54 54 55 55 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 56 56 57 -[[image:173 3328382380-760.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]59 +[[image:1735224224155-829.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] 58 58 59 59 In this section: 60 60 ... ... @@ -61,6 +61,7 @@ 61 61 * Enable – a flag to enable the protection; 62 62 * Minimum cell voltage, V; 63 63 * Tolerant cell voltage, V; 66 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 64 64 * Delay before setting the error, millisecond; 65 65 * Delay before clearing the error, second; 66 66 * Lock – a flag to block the error until the device is restarted. ... ... @@ -86,7 +86,7 @@ 86 86 87 87 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 88 88 89 -[[image:173 3328382382-607.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]92 +[[image:1735224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]] 90 90 91 91 In this section: 92 92 ... ... @@ -93,9 +93,9 @@ 93 93 * Enable – a flag to enable the protection; 94 94 * Maximum cell voltage, V; 95 95 * Tolerant cell voltage, V; 99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 96 96 * Delay before setting the error, millisecond; 97 97 * Delay before clearing the error, second; 98 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 99 99 * Lock – a flag to block the error until the device is restarted. 100 100 101 101 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -275,7 +275,7 @@ 275 275 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 276 276 ))) 277 277 278 -=== HighLogic temperature ===281 +=== Logic high temperature === 279 279 280 280 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 281 281 ... ... @@ -394,7 +394,7 @@ 394 394 395 395 To change the protection parameters from short circuit, select the "Protections → Short circuit" section: 396 396 397 -[[image:173 3328415733-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="210" width="800"]]400 +[[image:1735224667621-969.png]] 398 398 399 399 In this section: 400 400 ... ... @@ -509,6 +509,10 @@ 509 509 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 510 510 ))) 511 511 515 +=== Power fault === 516 + 517 +TBA 518 + 512 512 === Charge contactor cycles === 513 513 514 514 The BMS Main 3 device protects the charging contactor against frequent switching.
- 1735224224155-829.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1735224377252-473.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1735224601506-488.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- 1735224667621-969.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.8 KB - Content
- 1735224706573-347.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.1 KB - Content