Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS MainConfiguration.WebHome1 +drafts.bms-main-3.3\. Settings.WebHome - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration =2 += Settings = 3 3 4 4 (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Protections == ... ... @@ -294,9 +294,9 @@ 294 294 295 295 * a BMS Logic device temperature is less than the “Tolerant temperature” value. 296 296 297 -(% class="box in fomessage" %)297 +(% class="box warningmessage" %) 298 298 ((( 299 - Cell balancing is disabledonLogic deviceswithhightemperature.299 +Overheated Logic devices do not balance cells. 300 300 ))) 301 301 302 302 === Logic offline === ... ... @@ -586,7 +586,7 @@ 586 586 587 587 (% class="box warningmessage" %) 588 588 ((( 589 -If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 589 +If there is the “No temp. sensors” or “Temp. sensor is shorted” error, the **“Critical error”** is generated and **all relays open.** 590 590 ))) 591 591 592 592 === WDT reset === ... ... @@ -612,7 +612,7 @@ 612 612 If there is the "WDT reset" error, the **“Critical error” **is generated and **all relays open.** 613 613 ))) 614 614 615 -=== Unallowable charging === 615 +=== Unallowable charging === 616 616 617 617 The BMS can detect that the battery is charging through the discharging circuit and protectively open the discharging contactor to prevent unallowable battery operation. 618 618 ... ... @@ -642,7 +642,7 @@ 642 642 If there is the "Unallowable charging" error, the **discharging **contactor opens. 643 643 ))) 644 644 645 -=== Stuck contactor === 645 +=== Stuck contactor === 646 646 647 647 The BMS Main 3 device protects contactors against sticking. 648 648 ... ... @@ -692,8 +692,30 @@ 692 692 If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 693 693 ))) 694 694 695 -=== Insulation===695 +=== Precharge === 696 696 697 +BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. To change the pre-charge monitoring parameters, select the "Protections → Precharge" section: 698 + 699 +[[image:1733328487097-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="99" width="800"]] 700 + 701 +In this section: 702 + 703 +* Enable – a flag to enable the protection; 704 +* Delay before setting the error, millisecond; 705 +* Delay before clearing the error, second; 706 +* Lock – a flag to block the error until the device is restarted. 707 + 708 +As a result of the protection algorithms the “Precharge error” is generated. Error generation conditions: 709 + 710 +* precharging process cannot be finished (the precharge current does not decrease or voltages before and after contactors are not equal) during the “Delay before setting the error” time. 711 + 712 +(% class="box infomessage" %) 713 +((( 714 +If there is the “Precharge error”, **charging **and **discharging **contactors open. 715 +))) 716 + 717 +=== Insulation === 718 + 697 697 The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. 698 698 699 699 To change the insulation monitoring parameters, select the "Protections → Insulation" section: ... ... @@ -783,7 +783,7 @@ 783 783 If there is the “Critical error”, **all **contactors open. 784 784 ))) 785 785 786 -=== General error === 808 +=== General error === 787 787 788 788 To change the general error parameters, select the "Protections → Critical error" section: 789 789