Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,7 +12,7 @@ 12 12 13 13 To change the overcurrent protection of the battery, select the "Protections → Overcurrent" section: 14 14 15 -[[image:173 3328382376-958.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]15 +[[image:1735224601506-488.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 16 16 17 17 In this section: 18 18 ... ... @@ -42,6 +42,14 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 +=== Charge current limit === 46 + 47 +TBA 48 + 49 +=== Discharge current limit === 50 + 51 +TBA 52 + 45 45 === Undervoltage === 46 46 47 47 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -48,7 +48,7 @@ 48 48 49 49 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 50 50 51 -[[image:173 3328382380-760.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]59 +[[image:1735224224155-829.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] 52 52 53 53 In this section: 54 54 ... ... @@ -55,6 +55,7 @@ 55 55 * Enable – a flag to enable the protection; 56 56 * Minimum cell voltage, V; 57 57 * Tolerant cell voltage, V; 66 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 58 58 * Delay before setting the error, millisecond; 59 59 * Delay before clearing the error, second; 60 60 * Lock – a flag to block the error until the device is restarted. ... ... @@ -80,7 +80,7 @@ 80 80 81 81 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 82 82 83 -[[image:173 3328382382-607.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]92 +[[image:1735224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]] 84 84 85 85 In this section: 86 86 ... ... @@ -87,9 +87,9 @@ 87 87 * Enable – a flag to enable the protection; 88 88 * Maximum cell voltage, V; 89 89 * Tolerant cell voltage, V; 99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 90 90 * Delay before setting the error, millisecond; 91 91 * Delay before clearing the error, second; 92 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 93 93 * Lock – a flag to block the error until the device is restarted. 94 94 95 95 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -269,7 +269,7 @@ 269 269 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 270 270 ))) 271 271 272 -=== HighLogic temperature ===281 +=== Logic high temperature === 273 273 274 274 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 275 275 ... ... @@ -388,7 +388,7 @@ 388 388 389 389 To change the protection parameters from short circuit, select the "Protections → Short circuit" section: 390 390 391 -[[image:173 3328415733-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="210" width="800"]]400 +[[image:1735224667621-969.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="153" width="800"]] 392 392 393 393 In this section: 394 394 ... ... @@ -396,8 +396,6 @@ 396 396 ** Enable – a flag to enable the protection; 397 397 ** Maximum current, A; 398 398 ** Delay before setting the error, second; 399 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "Short circuit" error occurs; 400 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Short circuit" error occurs; 401 401 * Delay before clearing the error, second; 402 402 * Lock – a flag to block the error until the device is restarted. 403 403 ... ... @@ -422,7 +422,7 @@ 422 422 423 423 To change the overheating protection parameters of power contactors, select the "Protections → High contactor temperature" section: 424 424 425 -[[image:173 3328415734-986.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]432 +[[image:1735224706573-347.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] 426 426 427 427 In this section: 428 428 ... ... @@ -431,8 +431,6 @@ 431 431 * Maximum contactor temperature, °C; 432 432 * Tolerant contactor temperature, °C; 433 433 * Delay before setting the error, second; 434 -* Switch off the charging contactor on error – a flag to open the charging contactor when the "High contactor temperature" error occurs; 435 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "High contactor temperature" error occurs; 436 436 * Delay before clearing the error, second; 437 437 * Lock – a flag to block the error until the device is restarted. 438 438 ... ... @@ -503,6 +503,10 @@ 503 503 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 504 504 ))) 505 505 511 +=== Power fault === 512 + 513 +TBA 514 + 506 506 === Charge contactor cycles === 507 507 508 508 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -724,14 +724,18 @@ 724 724 725 725 To change the HVIL measurement parameters, select the "Protections → HVIL" section: 726 726 727 -[[image:173 3328487099-371.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]736 +[[image:1735224839441-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] 728 728 729 729 In this section: 730 730 731 731 * Enable – a flag to enable the protection; 741 +* Source is OFF: Lower current limit, A; 742 +* Source is OFF: Upper current limit, A; 743 +* Source is ON: Lower current limit, A; 744 +* Source is ON: Upper current limit, A; 732 732 * Lock – a flag to block the error until the device is restarted. 733 733 734 -If interlock loop breaks, the “HVIL error” is generated. Error clears if interlock loop is being restored. 747 +If interlock loop breaks and its current is out of the configured ranges, the “HVIL error” is generated. Error clears if interlock loop is being restored. 735 735 736 736 (% class="box warningmessage" %) 737 737 ((( ... ... @@ -787,7 +787,7 @@ 787 787 788 788 To change the general error parameters, select the "Protections → Critical error" section: 789 789 790 -[[image:173 3328487101-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]803 +[[image:1735224942262-497.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="102" width="800"]] 791 791 792 792 In this section: 793 793 ... ... @@ -795,7 +795,7 @@ 795 795 * Delay before setting the error, millisecond; 796 796 * Delay before clearing the error, second; 797 797 * Lock – a flag to block the error until the device is restarted; 798 -* Check: <error>– a flags to enable check of corresponding errors.811 +* Errors 1, 2 to set the – a flags to enable check of corresponding errors. 799 799 800 800 The general error flag is generated if at least one of the enabled errors is generated during the “Delay before setting the error” time. 801 801
- 1735224224155-829.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1735224377252-473.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1735224601506-488.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- 1735224667621-969.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.8 KB - Content
- 1735224706573-347.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.1 KB - Content
- 1735224839441-185.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.1 KB - Content
- 1735224942262-497.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content