Changes for page 3.4 Protections
Last modified by Admin on 2025/04/09 12:19
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,7 +12,7 @@ 12 12 13 13 To change the overcurrent protection of the battery, select the "Protections → Overcurrent" section: 14 14 15 -[[image:173 3328382376-958.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]15 +[[image:1735224601506-488.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 16 16 17 17 In this section: 18 18 ... ... @@ -42,6 +42,14 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 +=== Charge current limit === 46 + 47 +TBA 48 + 49 +=== Discharge current limit === 50 + 51 +TBA 52 + 45 45 === Undervoltage === 46 46 47 47 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -48,7 +48,7 @@ 48 48 49 49 To change the battery protection parameters from low voltage on the cells, select the "Protections → Undervoltage" section: 50 50 51 -[[image:173 3328382380-760.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]59 +[[image:1735224224155-829.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] 52 52 53 53 In this section: 54 54 ... ... @@ -55,6 +55,7 @@ 55 55 * Enable – a flag to enable the protection; 56 56 * Minimum cell voltage, V; 57 57 * Tolerant cell voltage, V; 66 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 58 58 * Delay before setting the error, millisecond; 59 59 * Delay before clearing the error, second; 60 60 * Lock – a flag to block the error until the device is restarted. ... ... @@ -80,7 +80,7 @@ 80 80 81 81 To change the battery protection parameters from high voltage on the cells, select the "Protections → Overvoltage" section: 82 82 83 -[[image:173 3328382382-607.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]92 +[[image:1735224377252-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]] 84 84 85 85 In this section: 86 86 ... ... @@ -87,9 +87,9 @@ 87 87 * Enable – a flag to enable the protection; 88 88 * Maximum cell voltage, V; 89 89 * Tolerant cell voltage, V; 99 +* Check the open circuit voltage instead of the actual voltage – a flag to enable the check of voltage correction due to current and cell resistance; 90 90 * Delay before setting the error, millisecond; 91 91 * Delay before clearing the error, second; 92 -* Switch off the discharging contactor on error – a flag to open the discharging contactor when the "Overvoltage" error is generated; 93 93 * Lock – a flag to block the error until the device is restarted. 94 94 95 95 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. ... ... @@ -269,7 +269,7 @@ 269 269 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 270 270 ))) 271 271 272 -=== HighLogic temperature ===281 +=== Logic high temperature === 273 273 274 274 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 275 275 ... ... @@ -388,7 +388,7 @@ 388 388 389 389 To change the protection parameters from short circuit, select the "Protections → Short circuit" section: 390 390 391 -[[image:173 3328415733-309.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="210" width="800"]]400 +[[image:1735224667621-969.png]] 392 392 393 393 In this section: 394 394 ... ... @@ -503,6 +503,10 @@ 503 503 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 504 504 ))) 505 505 515 +=== Power fault === 516 + 517 +TBA 518 + 506 506 === Charge contactor cycles === 507 507 508 508 The BMS Main 3 device protects the charging contactor against frequent switching.
- 1735224224155-829.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1735224377252-473.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- 1735224601506-488.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- 1735224667621-969.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.8 KB - Content