Changes for page 3.4 Protections
Last modified by Admin on 2026/04/01 08:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,12 +92,12 @@ 92 92 In this section: 93 93 94 94 * **Enable **– a flag to enable the protection; 95 -* **Minimum cell voltage**, V;96 -* **Tolerant cell voltage**, V;97 -* **Check the open circuit voltage instead of the actual voltage**– a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;98 -* **Delay before setting the error**, millisecond;99 -* **Delay before clearing the error**, second;100 -* **Lock**– a flag to block the error until the device is restarted.95 +* Minimum cell voltage, V; 96 +* Tolerant cell voltage, V; 97 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 98 +* Delay before setting the error, millisecond; 99 +* Delay before clearing the error, second; 100 +* Lock – a flag to block the error until the device is restarted. 101 101 102 102 As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated. 103 103 ... ... @@ -119,13 +119,13 @@ 119 119 120 120 In this section: 121 121 122 -* **Enable**– a flag to enable the protection;123 -* **Maximum cell voltage**, V;124 -* **Tolerant cell voltage**, V;125 -* **Check the open circuit voltage instead of the actual voltage**– a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;126 -* **Delay before setting the error**, millisecond;127 -* **Delay before clearing the error**, second;128 -* **Lock**– a flag to block the error until the device is restarted.122 +* Enable – a flag to enable the protection; 123 +* Maximum cell voltage, V; 124 +* Tolerant cell voltage, V; 125 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 126 +* Delay before setting the error, millisecond; 127 +* Delay before clearing the error, second; 128 +* Lock – a flag to block the error until the device is restarted. 129 129 130 130 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 131 131 ... ... @@ -145,12 +145,12 @@ 145 145 146 146 [[image:1760437465709-702.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]In this section: 147 147 148 -* **Enable**– a flag to enable the protection;149 -* **Maximum cell imbalance**, V;150 -* **Tolerant cell imbalance**, V;151 -* **Delay before setting the error**, millisecond;152 -* **Delay before clearing the error**, second;153 -* **Lock**– a flag to block the error until the device is restarted.148 +* Enable – a flag to enable the protection; 149 +* Maximum cell imbalance, V; 150 +* Tolerant cell imbalance, V; 151 +* Delay before setting the error, millisecond; 152 +* Delay before clearing the error, second; 153 +* Lock – a flag to block the error until the device is restarted. 154 154 155 155 As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 156 156 ... ... @@ -172,14 +172,14 @@ 172 172 173 173 In this section: 174 174 175 -* **Enable**– a flag to enable the protection;176 -* **Minimum charge temperature**, °C;177 -* **Tolerant charge temperature**, °C;178 -* **Minimum discharge temperature**, °C;179 -* **Tolerant discharge temperature**, °C;180 -* **Delay before setting the error**, millisecond;181 -* **Delay before clearing the error**, second;182 -* **Lock**– a flag to block the error until the device is restarted.175 +* Enable – a flag to enable the protection; 176 +* Minimum charge temperature, °C; 177 +* Tolerant charge temperature, °C; 178 +* Minimum discharge temperature, °C; 179 +* Tolerant discharge temperature, °C; 180 +* Delay before setting the error, millisecond; 181 +* Delay before clearing the error, second; 182 +* Lock – a flag to block the error until the device is restarted. 183 183 184 184 As a result of the operation of the battery protection from low temperature, the "Low temperature (CH)" and/or “Low temperature (DCH)” error are generated. 185 185 ... ... @@ -201,14 +201,14 @@ 201 201 202 202 In this section: 203 203 204 -* **Enable**– a flag to enable the protection;205 -* **Maximum charge temperature**, °C;206 -* **Tolerant charge temperature**, °C;207 -* **Maximum discharge temperature**, °C;208 -* **Tolerant discharge temperature**, °C;209 -* **Delay before setting the error**, millisecond;210 -* **Delay before clearing the error**, second;211 -* **Lock**– a flag to block the error until the device is restarted.204 +* Enable – a flag to enable the protection; 205 +* Maximum charge temperature, °C; 206 +* Tolerant charge temperature, °C; 207 +* Maximum discharge temperature, °C; 208 +* Tolerant discharge temperature, °C; 209 +* Delay before setting the error, millisecond; 210 +* Delay before clearing the error, second; 211 +* Lock – a flag to block the error until the device is restarted. 212 212 213 213 As a result of the operation of the battery protection from high temperature, the "High temperature (CH)" or “High temperature (DCH)” error is generated. 214 214 ... ... @@ -228,10 +228,10 @@ 228 228 229 229 In this section: 230 230 231 -* **Enable**– a flag to enable the protection;232 -* **Delay before setting the error**, millisecond;233 -* **Delay before clearing the error**, second;234 -* **Lock**– a flag to block the error until the device is restarted.231 +* Enable – a flag to enable the protection; 232 +* Delay before setting the error, millisecond; 233 +* Delay before clearing the error, second; 234 +* Lock – a flag to block the error until the device is restarted. 235 235 236 236 As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 237 237 ... ... @@ -258,12 +258,12 @@ 258 258 259 259 In this section: 260 260 261 -* **Enable**– a flag to enable the detection;262 -* **Maximum humidity**, RH%;263 -* **Tolerant humidity**, RH%;264 -* **Delay before setting the error**, second;265 -* **Delay before clearing the error**, second;266 -* **Lock**– a flagto block the error until the device is restarted.261 +* Enable – a flag to enable the detection; 262 +* Maximum humidity, RH%; 263 +* Tolerant humidity, RH%; 264 +* Delay before setting the error, second; 265 +* Delay before clearing the error, second; 266 +* Lock the error until the device is reset. 267 267 268 268 As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 269 269 ... ... @@ -290,12 +290,12 @@ 290 290 291 291 In this section: 292 292 293 -* **Enable**– a flag to enable the protection;294 -* **Maximum humidity**, RH%;295 -* **Tolerant humidity**, RH%;296 -* **Delay before setting the error**, second;297 -* **Delay before clearing the error**, second;298 -* **Lock**– lock the error until the device is reset.293 +* Enable – a flag to enable the protection; 294 +* Maximum humidity, RH%; 295 +* Tolerant humidity, RH%; 296 +* Delay before setting the error, second; 297 +* Delay before clearing the error, second; 298 +* Lock – lock the error until the device is reset. 299 299 300 300 As a result of the operation of the battery protection from water, the "Water" error is generated. 301 301 ... ... @@ -320,12 +320,12 @@ 320 320 321 321 In this section: 322 322 323 -* **Enable**– a flag to enable the protection;324 -* **Maximum temperature**, °C;325 -* **Tolerant temperature**, °C;326 -* **Delay before setting the error**, second;327 -* **Delay before clearing the error**, second;328 -* **Lock**– lock the error until the device is reset.323 +* Enable – a flag to enable the protection; 324 +* Maximum temperature, °C; 325 +* Tolerant temperature, °C; 326 +* Delay before setting the error, second; 327 +* Delay before clearing the error, second; 328 +* Lock – lock the error until the device is reset. 329 329 330 330 As a result of the operation of the protection from high temperatures of BMS Logic devices, the "High Logic temperature" is generated. 331 331 ... ... @@ -351,10 +351,10 @@ 351 351 352 352 In this section: 353 353 354 -* **Enable**– a flag to enable the protection;355 -* **Delay before setting the error**, second;356 -* **Delay before clearing the error**, second;357 -* **Lock**– lock the error until the device is reset.354 +* Enable – a flag to enable the protection; 355 +* Delay before setting the error, second; 356 +* Delay before clearing the error, second; 357 +* Lock – lock the error until the device is reset. 358 358 359 359 As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated. 360 360 ... ... @@ -379,11 +379,11 @@ 379 379 380 380 In this section: 381 381 382 -* **Enable**– a flag to enable the protection;383 -* **Number of cells**– a number of cells connected to the BMS;384 -* **Delay before setting the error**, millisecond;385 -* **Delay before clearing the error**, second;386 -* **Lock**– a flag to block the error until the device is restarted.382 +* Enable – a flag to enable the protection; 383 +* Number of cells – a number of cells connected to the BMS; 384 +* Delay before setting the error, millisecond; 385 +* Delay before clearing the error, second; 386 +* Lock – a flag to block the error until the device is restarted. 387 387 388 388 As a result of the operation of the protection from the mismatch of the number of cells, the "Cell count error" is generated. 389 389 ... ... @@ -408,11 +408,11 @@ 408 408 409 409 In this section: 410 410 411 -* **Enable**– a flag to enable the protection;412 -* **Number of cells**– a number of temperature sensors connected to the BMS;413 -* **Delay before setting the error**, millisecond;414 -* **Delay before clearing the error**, second;415 -* **Lock**– a flag to block the error until the device is restarted.411 +* Enable – a flag to enable the protection; 412 +* Number of cells – a number of temperature sensors connected to the BMS; 413 +* Delay before setting the error, millisecond; 414 +* Delay before clearing the error, second; 415 +* Lock – a flag to block the error until the device is restarted. 416 416 417 417 As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 418 418 ... ... @@ -437,12 +437,12 @@ 437 437 438 438 In this section: 439 439 440 -* **Enable**– a flag to enable the protection;441 -* **Logic count**– a number of BMS Logic devices connected to the BMS Main;442 -* **Scan fast**– a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);443 -* **Delay before setting the error**– a delay before setting the error //during initialization//, millisecond;444 -* **Delay before clearing the error**– a delay before clearing the error //during initialization//, second;445 -* **Lock**– lock the error until the device is reset.440 +* Enable – a flag to enable the protection; 441 +* Logic count – a number of BMS Logic devices connected to the BMS Main; 442 +* Scan fast – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 443 +* Delay before setting the error – a delay before setting the error //during initialization//, millisecond; 444 +* Delay before clearing the error– a delay before clearing the error //during initialization//, second; 445 +* Lock – lock the error until the device is reset. 446 446 447 447 As a result of the operation of the protection from the mismatch of the number of BMS Logic devices, the "Logic count error" is generated. 448 448 ... ... @@ -471,12 +471,12 @@ 471 471 472 472 In this section: 473 473 474 -* **Level 1, 2, 3**– three protection levels. The following parameters are configured at each level:475 -** **Enable**– a flag to enable the protection;476 -** **Maximum current**, A;477 -** **Delay before setting the error**, second;478 -* **Delay before clearing the error**, second;479 -* **Lock**– a flag to block the error until the device is restarted.474 +* Level 1, 2, 3 – three protection levels. The following parameters are configured at each level: 475 +** Enable – a flag to enable the protection; 476 +** Maximum current, A; 477 +** Delay before setting the error, second; 478 +* Delay before clearing the error, second; 479 +* Lock – a flag to block the error until the device is restarted. 480 480 481 481 If there is a short circuit, the "Short circuit" error is generated. 482 482 ... ... @@ -498,13 +498,13 @@ 498 498 499 499 In this section: 500 500 501 -* **Enable**– a flag to enable the protection;502 -* **Thermistor**– a selection of which cell thermistor will be used as contactor temperature sensor;503 -* **Maximum contactor temperature**, °C;504 -* **Tolerant contactor temperature**, °C;505 -* **Delay before setting the error**, second;506 -* **Delay before clearing the error**, second;507 -* **Lock**– a flag to block the error until the device is restarted.501 +* Enable – a flag to enable the protection; 502 +* Thermistor – a selection of which cell thermistor will be used as contactor temperature sensor; 503 +* Maximum contactor temperature, °C; 504 +* Tolerant contactor temperature, °C; 505 +* Delay before setting the error, second; 506 +* Delay before clearing the error, second; 507 +* Lock – a flag to block the error until the device is restarted. 508 508 509 509 If there is a contactor overheat, the "High contactor temperature" error is generated. 510 510