Changes for page 3.4 Protections
Last modified by Admin on 2026/04/01 08:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -231,7 +231,7 @@ 231 231 * **Enable** – a flag to enable the protection; 232 232 * **Delay before setting the error**, millisecond; 233 233 * **Delay before clearing the error**, second; 234 -* **Lock **– a flag toblockthe error until the device is restarted.234 +* **Lock **–Lock . 235 235 236 236 As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 237 237 ... ... @@ -263,7 +263,7 @@ 263 263 * **Tolerant humidity**, RH%; 264 264 * **Delay before setting the error**, second; 265 265 * **Delay before clearing the error**, second; 266 -* **Lock **– a flag toblock the error until the device is restarted.266 +* **Lock **– lock the error until the device is reset. 267 267 268 268 As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 269 269 ... ... @@ -290,12 +290,12 @@ 290 290 291 291 In this section: 292 292 293 -* **Enable**– a flag to enable the protection;294 -* **Maximum humidity**, RH%;295 -* **Tolerant humidity**, RH%;296 -* **Delay before setting the error**, second;297 -* **Delay before clearing the error**, second;298 -* **Lock**– lock the error until the device is reset.293 +* Enable – a flag to enable the protection; 294 +* Maximum humidity, RH%; 295 +* Tolerant humidity, RH%; 296 +* Delay before setting the error, second; 297 +* Delay before clearing the error, second; 298 +* Lock – lock the error until the device is reset. 299 299 300 300 As a result of the operation of the battery protection from water, the "Water" error is generated. 301 301 ... ... @@ -320,12 +320,12 @@ 320 320 321 321 In this section: 322 322 323 -* **Enable**– a flag to enable the protection;324 -* **Maximum temperature**, °C;325 -* **Tolerant temperature**, °C;326 -* **Delay before setting the error**, second;327 -* **Delay before clearing the error**, second;328 -* **Lock**– lock the error until the device is reset.323 +* Enable – a flag to enable the protection; 324 +* Maximum temperature, °C; 325 +* Tolerant temperature, °C; 326 +* Delay before setting the error, second; 327 +* Delay before clearing the error, second; 328 +* Lock – lock the error until the device is reset. 329 329 330 330 As a result of the operation of the protection from high temperatures of BMS Logic devices, the "High Logic temperature" is generated. 331 331 ... ... @@ -351,10 +351,10 @@ 351 351 352 352 In this section: 353 353 354 -* **Enable**– a flag to enable the protection;355 -* **Delay before setting the error**, second;356 -* **Delay before clearing the error**, second;357 -* **Lock**– lock the error until the device is reset.354 +* Enable – a flag to enable the protection; 355 +* Delay before setting the error, second; 356 +* Delay before clearing the error, second; 357 +* Lock – lock the error until the device is reset. 358 358 359 359 As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated. 360 360 ... ... @@ -379,11 +379,11 @@ 379 379 380 380 In this section: 381 381 382 -* **Enable**– a flag to enable the protection;383 -* **Number of cells**– a number of cells connected to the BMS;384 -* **Delay before setting the error**, millisecond;385 -* **Delay before clearing the error**, second;386 -* **Lock**– a flag to block the error until the device is restarted.382 +* Enable – a flag to enable the protection; 383 +* Number of cells – a number of cells connected to the BMS; 384 +* Delay before setting the error, millisecond; 385 +* Delay before clearing the error, second; 386 +* Lock – a flag to block the error until the device is restarted. 387 387 388 388 As a result of the operation of the protection from the mismatch of the number of cells, the "Cell count error" is generated. 389 389 ... ... @@ -408,7 +408,7 @@ 408 408 409 409 In this section: 410 410 411 -* **Enable**– a flag to enable the protection;411 +* Enable – a flag to enable the protection; 412 412 * Number of cells – a number of temperature sensors connected to the BMS; 413 413 * Delay before setting the error, millisecond; 414 414 * Delay before clearing the error, second;