Changes for page 3.4 Protections
Last modified by Admin on 2026/04/01 08:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -231,7 +231,7 @@ 231 231 * **Enable** – a flag to enable the protection; 232 232 * **Delay before setting the error**, millisecond; 233 233 * **Delay before clearing the error**, second; 234 -* **Lock **– Lock .234 +* **Lock **– a flag to block the error until the device is restarted. 235 235 236 236 As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 237 237 ... ... @@ -263,7 +263,7 @@ 263 263 * **Tolerant humidity**, RH%; 264 264 * **Delay before setting the error**, second; 265 265 * **Delay before clearing the error**, second; 266 -* **Lock **– lock the error until the device is res et.266 +* **Lock **– a flag to block the error until the device is restarted. 267 267 268 268 As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 269 269 ... ... @@ -290,12 +290,12 @@ 290 290 291 291 In this section: 292 292 293 -* Enable – a flag to enable the protection;294 -* Maximum humidity, RH%; 295 -* Tolerant humidity, RH%; 296 -* Delay before setting the error, second; 297 -* Delay before clearing the error, second; 298 -* Lock – lock the error until the device is reset. 293 +* **Enable **– a flag to enable the protection; 294 +* **Maximum humidity**, RH%; 295 +* **Tolerant humidity**, RH%; 296 +* **Delay before setting the error**, second; 297 +* **Delay before clearing the error**, second; 298 +* **Lock **– lock the error until the device is reset. 299 299 300 300 As a result of the operation of the battery protection from water, the "Water" error is generated. 301 301 ... ... @@ -320,12 +320,12 @@ 320 320 321 321 In this section: 322 322 323 -* Enable – a flag to enable the protection; 324 -* Maximum temperature, °C; 325 -* Tolerant temperature, °C; 326 -* Delay before setting the error, second; 327 -* Delay before clearing the error, second; 328 -* Lock – lock the error until the device is reset. 323 +* **Enable **– a flag to enable the protection; 324 +* **Maximum temperature**, °C; 325 +* **Tolerant temperature**, °C; 326 +* **Delay before setting the error**, second; 327 +* **Delay before clearing the error**, second; 328 +* **Lock **– lock the error until the device is reset. 329 329 330 330 As a result of the operation of the protection from high temperatures of BMS Logic devices, the "High Logic temperature" is generated. 331 331 ... ... @@ -351,10 +351,10 @@ 351 351 352 352 In this section: 353 353 354 -* Enable – a flag to enable the protection; 355 -* Delay before setting the error, second; 356 -* Delay before clearing the error, second; 357 -* Lock – lock the error until the device is reset. 354 +* **Enable **– a flag to enable the protection; 355 +* **Delay before setting the error**, second; 356 +* **Delay before clearing the error**, second; 357 +* **Lock **– lock the error until the device is reset. 358 358 359 359 As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated. 360 360 ... ... @@ -379,11 +379,11 @@ 379 379 380 380 In this section: 381 381 382 -* Enable – a flag to enable the protection; 383 -* Number of cells – a number of cells connected to the BMS; 384 -* Delay before setting the error, millisecond; 385 -* Delay before clearing the error, second; 386 -* Lock – a flag to block the error until the device is restarted. 382 +* **Enable** – a flag to enable the protection; 383 +* **Number of cells** – a number of cells connected to the BMS; 384 +* **Delay before setting the error**, millisecond; 385 +* **Delay before clearing the error**, second; 386 +* **Lock **– a flag to block the error until the device is restarted. 387 387 388 388 As a result of the operation of the protection from the mismatch of the number of cells, the "Cell count error" is generated. 389 389 ... ... @@ -408,11 +408,11 @@ 408 408 409 409 In this section: 410 410 411 -* Enable – a flag to enable the protection; 412 -* Number of cells – a number of temperature sensors connected to the BMS; 413 -* Delay before setting the error, millisecond; 414 -* Delay before clearing the error, second; 415 -* Lock – a flag to block the error until the device is restarted. 411 +* **Enable **– a flag to enable the protection; 412 +* **Number of cells** – a number of temperature sensors connected to the BMS; 413 +* **Delay before setting the error**, millisecond; 414 +* **Delay before clearing the error**, second; 415 +* **Lock **– a flag to block the error until the device is restarted. 416 416 417 417 As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 418 418 ... ... @@ -437,12 +437,12 @@ 437 437 438 438 In this section: 439 439 440 -* Enable – a flag to enable the protection; 441 -* Logic count – a number of BMS Logic devices connected to the BMS Main; 442 -* Scan fast – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 443 -* Delay before setting the error – a delay before setting the error //during initialization//, millisecond; 444 -* Delay before clearing the error– a delay before clearing the error //during initialization//, second; 445 -* Lock – lock the error until the device is reset. 440 +* **Enable **– a flag to enable the protection; 441 +* **Logic count** – a number of BMS Logic devices connected to the BMS Main; 442 +* **Scan fast** – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 443 +* **Delay before setting the error** – a delay before setting the error //during initialization//, millisecond; 444 +* **Delay before clearing the error **– a delay before clearing the error //during initialization//, second; 445 +* **Lock** – lock the error until the device is reset. 446 446 447 447 As a result of the operation of the protection from the mismatch of the number of BMS Logic devices, the "Logic count error" is generated. 448 448 ... ... @@ -471,12 +471,12 @@ 471 471 472 472 In this section: 473 473 474 -* Level 1, 2, 3 – three protection levels. The following parameters are configured at each level: 475 -** Enable – a flag to enable the protection; 476 -** Maximum current, A; 477 -** Delay before setting the error, second; 478 -* Delay before clearing the error, second; 479 -* Lock – a flag to block the error until the device is restarted. 474 +* **Level 1, 2, 3** – three protection levels. The following parameters are configured at each level: 475 +** **Enable **– a flag to enable the protection; 476 +** **Maximum current**, A; 477 +** **Delay before setting the error**, second; 478 +* **Delay before clearing the error**, second; 479 +* **Lock **– a flag to block the error until the device is restarted. 480 480 481 481 If there is a short circuit, the "Short circuit" error is generated. 482 482 ... ... @@ -498,13 +498,13 @@ 498 498 499 499 In this section: 500 500 501 -* Enable – a flag to enable the protection; 502 -* Thermistor – a selection of which cell thermistor will be used as contactor temperature sensor; 503 -* Maximum contactor temperature, °C; 504 -* Tolerant contactor temperature, °C; 505 -* Delay before setting the error, second; 506 -* Delay before clearing the error, second; 507 -* Lock – a flag to block the error until the device is restarted. 501 +* **Enable** – a flag to enable the protection; 502 +* **Thermistor **– a selection of which cell thermistor will be used as contactor temperature sensor; 503 +* **Maximum contactor temperature**, °C; 504 +* **Tolerant contactor temperature**, °C; 505 +* **Delay before setting the error**, second; 506 +* **Delay before clearing the error**, second; 507 +* **Lock **– a flag to block the error until the device is restarted. 508 508 509 509 If there is a contactor overheat, the "High contactor temperature" error is generated. 510 510