- Content
-
... ... @@ -178,8 +178,8 @@ 178 178 * **Minimum discharge temperature**, °C; 179 179 * **Tolerant discharge temperature**, °C; 180 180 * **Delay before setting the error**, millisecond; 181 -* **Delay before clearing the error**, second;182 -* **Lock**– a flag to block the error until the device is restarted.181 +* Delay before clearing the error, second; 182 +* Lock – a flag to block the error until the device is restarted. 183 183 184 184 As a result of the operation of the battery protection from low temperature, the "Low temperature (CH)" and/or “Low temperature (DCH)” error are generated. 185 185 ... ... @@ -201,14 +201,14 @@ 201 201 202 202 In this section: 203 203 204 -* **Enable**– a flag to enable the protection;205 -* **Maximum charge temperature**, °C;206 -* **Tolerant charge temperature**, °C;207 -* **Maximum discharge temperature**, °C;208 -* **Tolerant discharge temperature**, °C;209 -* **Delay before setting the error**, millisecond;210 -* **Delay before clearing the error**, second;211 -* **Lock**– a flag to block the error until the device is restarted.204 +* Enable – a flag to enable the protection; 205 +* Maximum charge temperature, °C; 206 +* Tolerant charge temperature, °C; 207 +* Maximum discharge temperature, °C; 208 +* Tolerant discharge temperature, °C; 209 +* Delay before setting the error, millisecond; 210 +* Delay before clearing the error, second; 211 +* Lock – a flag to block the error until the device is restarted. 212 212 213 213 As a result of the operation of the battery protection from high temperature, the "High temperature (CH)" or “High temperature (DCH)” error is generated. 214 214 ... ... @@ -228,10 +228,10 @@ 228 228 229 229 In this section: 230 230 231 -* **Enable**– a flag to enable the protection;232 -* **Delay before setting the error**, millisecond;233 -* **Delay before clearing the error**, second;234 -* **Lock**–Lock .231 +* Enable – a flag to enable the protection; 232 +* Delay before setting the error, millisecond; 233 +* Delay before clearing the error, second; 234 +* Lock – a flag to block the error until the device is restarted. 235 235 236 236 As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 237 237 ... ... @@ -258,12 +258,12 @@ 258 258 259 259 In this section: 260 260 261 -* **Enable**– a flag to enable the detection;262 -* **Maximum humidity**, RH%;263 -* **Tolerant humidity**, RH%;264 -* **Delay before setting the error**, second;265 -* **Delay before clearing the error**, second;266 -* **Lock**– lockthe error until the device is reset.261 +* Enable – a flag to enable the detection; 262 +* Maximum humidity, RH%; 263 +* Tolerant humidity, RH%; 264 +* Delay before setting the error, second; 265 +* Delay before clearing the error, second; 266 +* Lock the error until the device is reset. 267 267 268 268 As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 269 269