Changes for page 3.4 Protections
Last modified by Admin on 2026/04/01 08:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,12 +92,12 @@ 92 92 In this section: 93 93 94 94 * **Enable **– a flag to enable the protection; 95 -* **Minimum cell voltage**, V;96 -* **Tolerant cell voltage**, V;97 -* **Check the open circuit voltage instead of the actual voltage**– a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;98 -* **Delay before setting the error**, millisecond;99 -* **Delay before clearing the error**, second;100 -* **Lock**– a flag to block the error until the device is restarted.95 +* Minimum cell voltage, V; 96 +* Tolerant cell voltage, V; 97 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 98 +* Delay before setting the error, millisecond; 99 +* Delay before clearing the error, second; 100 +* Lock – a flag to block the error until the device is restarted. 101 101 102 102 As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated. 103 103 ... ... @@ -119,13 +119,13 @@ 119 119 120 120 In this section: 121 121 122 -* **Enable**– a flag to enable the protection;123 -* **Maximum cell voltage**, V;124 -* **Tolerant cell voltage**, V;125 -* **Check the open circuit voltage instead of the actual voltage**– a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;126 -* **Delay before setting the error**, millisecond;127 -* **Delay before clearing the error**, second;128 -* **Lock**– a flag to block the error until the device is restarted.122 +* Enable – a flag to enable the protection; 123 +* Maximum cell voltage, V; 124 +* Tolerant cell voltage, V; 125 +* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 126 +* Delay before setting the error, millisecond; 127 +* Delay before clearing the error, second; 128 +* Lock – a flag to block the error until the device is restarted. 129 129 130 130 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 131 131 ... ... @@ -145,12 +145,12 @@ 145 145 146 146 [[image:1760437465709-702.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]In this section: 147 147 148 -* **Enable**– a flag to enable the protection;149 -* **Maximum cell imbalance**, V;150 -* **Tolerant cell imbalance**, V;151 -* **Delay before setting the error**, millisecond;152 -* **Delay before clearing the error**, second;153 -* **Lock**– a flag to block the error until the device is restarted.148 +* Enable – a flag to enable the protection; 149 +* Maximum cell imbalance, V; 150 +* Tolerant cell imbalance, V; 151 +* Delay before setting the error, millisecond; 152 +* Delay before clearing the error, second; 153 +* Lock – a flag to block the error until the device is restarted. 154 154 155 155 As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 156 156 ... ... @@ -172,12 +172,12 @@ 172 172 173 173 In this section: 174 174 175 -* **Enable**– a flag to enable the protection;176 -* **Minimum charge temperature**, °C;177 -* **Tolerant charge temperature**, °C;178 -* **Minimum discharge temperature**, °C;179 -* **Tolerant discharge temperature**, °C;180 -* **Delay before setting the error**, millisecond;175 +* Enable – a flag to enable the protection; 176 +* Minimum charge temperature, °C; 177 +* Tolerant charge temperature, °C; 178 +* Minimum discharge temperature, °C; 179 +* Tolerant discharge temperature, °C; 180 +* Delay before setting the error, millisecond; 181 181 * Delay before clearing the error, second; 182 182 * Lock – a flag to block the error until the device is restarted. 183 183