Changes for page 3.4 Protections
Last modified by Admin on 2026/04/01 08:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,12 +92,12 @@ 92 92 In this section: 93 93 94 94 * **Enable **– a flag to enable the protection; 95 -* Minimum cell voltage, V; 96 -* Tolerant cell voltage, V; 97 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 98 -* Delay before setting the error, millisecond; 99 -* Delay before clearing the error, second; 100 -* Lock – a flag to block the error until the device is restarted. 95 +* **Minimum cell voltage**, V; 96 +* **Tolerant cell voltage**, V; 97 +* **Check the open circuit voltage instead of the actual voltage** – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 98 +* **Delay before setting the error**, millisecond; 99 +* **Delay before clearing the error**, second; 100 +* **Lock **– a flag to block the error until the device is restarted. 101 101 102 102 As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated. 103 103 ... ... @@ -119,13 +119,13 @@ 119 119 120 120 In this section: 121 121 122 -* Enable – a flag to enable the protection; 123 -* Maximum cell voltage, V; 124 -* Tolerant cell voltage, V; 125 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 126 -* Delay before setting the error, millisecond; 127 -* Delay before clearing the error, second; 128 -* Lock – a flag to block the error until the device is restarted. 122 +* **Enable **– a flag to enable the protection; 123 +* **Maximum cell voltage**, V; 124 +* **Tolerant cell voltage**, V; 125 +* **Check the open circuit voltage instead of the actual voltage** – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 126 +* **Delay before setting the error**, millisecond; 127 +* **Delay before clearing the error**, second; 128 +* **Lock **– a flag to block the error until the device is restarted. 129 129 130 130 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 131 131 ... ... @@ -145,12 +145,12 @@ 145 145 146 146 [[image:1760437465709-702.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]In this section: 147 147 148 -* Enable – a flag to enable the protection; 149 -* Maximum cell imbalance, V; 150 -* Tolerant cell imbalance, V; 151 -* Delay before setting the error, millisecond; 152 -* Delay before clearing the error, second; 153 -* Lock – a flag to block the error until the device is restarted. 148 +* **Enable **– a flag to enable the protection; 149 +* **Maximum cell imbalance**, V; 150 +* **Tolerant cell imbalance**, V; 151 +* **Delay before setting the error**, millisecond; 152 +* **Delay before clearing the error**, second; 153 +* **Lock **– a flag to block the error until the device is restarted. 154 154 155 155 As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 156 156 ... ... @@ -172,14 +172,14 @@ 172 172 173 173 In this section: 174 174 175 -* Enable – a flag to enable the protection; 176 -* Minimum charge temperature, °C; 177 -* Tolerant charge temperature, °C; 178 -* Minimum discharge temperature, °C; 179 -* Tolerant discharge temperature, °C; 180 -* Delay before setting the error, millisecond; 181 -* Delay before clearing the error, second; 182 -* Lock – a flag to block the error until the device is restarted. 175 +* **Enable **– a flag to enable the protection; 176 +* **Minimum charge temperature**, °C; 177 +* **Tolerant charge temperature**, °C; 178 +* **Minimum discharge temperature**, °C; 179 +* **Tolerant discharge temperature**, °C; 180 +* **Delay before setting the error**, millisecond; 181 +* **Delay before clearing the error**, second; 182 +* **Lock **– a flag to block the error until the device is restarted. 183 183 184 184 As a result of the operation of the battery protection from low temperature, the "Low temperature (CH)" and/or “Low temperature (DCH)” error are generated. 185 185 ... ... @@ -201,14 +201,14 @@ 201 201 202 202 In this section: 203 203 204 -* Enable – a flag to enable the protection; 205 -* Maximum charge temperature, °C; 206 -* Tolerant charge temperature, °C; 207 -* Maximum discharge temperature, °C; 208 -* Tolerant discharge temperature, °C; 209 -* Delay before setting the error, millisecond; 210 -* Delay before clearing the error, second; 211 -* Lock – a flag to block the error until the device is restarted. 204 +* **Enable **– a flag to enable the protection; 205 +* **Maximum charge temperature**, °C; 206 +* **Tolerant charge temperature**, °C; 207 +* **Maximum discharge temperature**, °C; 208 +* **Tolerant discharge temperature**, °C; 209 +* **Delay before setting the error**, millisecond; 210 +* **Delay before clearing the error**, second; 211 +* **Lock **– a flag to block the error until the device is restarted. 212 212 213 213 As a result of the operation of the battery protection from high temperature, the "High temperature (CH)" or “High temperature (DCH)” error is generated. 214 214 ... ... @@ -228,10 +228,10 @@ 228 228 229 229 In this section: 230 230 231 -* Enable – a flag to enable the protection; 232 -* Delay before setting the error, millisecond; 233 -* Delay before clearing the error, second; 234 -* Lock – a flag to block the error until the device is restarted. 231 +* **Enable** – a flag to enable the protection; 232 +* **Delay before setting the error**, millisecond; 233 +* **Delay before clearing the error**, second; 234 +* **Lock **– a flag to block the error until the device is restarted. 235 235 236 236 As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 237 237 ... ... @@ -258,12 +258,12 @@ 258 258 259 259 In this section: 260 260 261 -* Enable – a flag to enable the detection; 262 -* Maximum humidity, RH%; 263 -* Tolerant humidity, RH%; 264 -* Delay before setting the error, second; 265 -* Delay before clearing the error, second; 266 -* Lock the error until the device is res et.261 +* **Enable **– a flag to enable the detection; 262 +* **Maximum humidity**, RH%; 263 +* **Tolerant humidity**, RH%; 264 +* **Delay before setting the error**, second; 265 +* **Delay before clearing the error**, second; 266 +* **Lock **– a flag to block the error until the device is restarted. 267 267 268 268 As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 269 269 ... ... @@ -290,12 +290,12 @@ 290 290 291 291 In this section: 292 292 293 -* Enable – a flag to enable the protection;294 -* Maximum humidity, RH%; 295 -* Tolerant humidity, RH%; 296 -* Delay before setting the error, second; 297 -* Delay before clearing the error, second; 298 -* Lock – lock the error until the device is reset. 293 +* **Enable **– a flag to enable the protection; 294 +* **Maximum humidity**, RH%; 295 +* **Tolerant humidity**, RH%; 296 +* **Delay before setting the error**, second; 297 +* **Delay before clearing the error**, second; 298 +* **Lock **– lock the error until the device is reset. 299 299 300 300 As a result of the operation of the battery protection from water, the "Water" error is generated. 301 301 ... ... @@ -320,12 +320,12 @@ 320 320 321 321 In this section: 322 322 323 -* Enable – a flag to enable the protection; 324 -* Maximum temperature, °C; 325 -* Tolerant temperature, °C; 326 -* Delay before setting the error, second; 327 -* Delay before clearing the error, second; 328 -* Lock – lock the error until the device is reset. 323 +* **Enable **– a flag to enable the protection; 324 +* **Maximum temperature**, °C; 325 +* **Tolerant temperature**, °C; 326 +* **Delay before setting the error**, second; 327 +* **Delay before clearing the error**, second; 328 +* **Lock **– lock the error until the device is reset. 329 329 330 330 As a result of the operation of the protection from high temperatures of BMS Logic devices, the "High Logic temperature" is generated. 331 331 ... ... @@ -351,10 +351,10 @@ 351 351 352 352 In this section: 353 353 354 -* Enable – a flag to enable the protection; 355 -* Delay before setting the error, second; 356 -* Delay before clearing the error, second; 357 -* Lock – lock the error until the device is reset. 354 +* **Enable **– a flag to enable the protection; 355 +* **Delay before setting the error**, second; 356 +* **Delay before clearing the error**, second; 357 +* **Lock **– lock the error until the device is reset. 358 358 359 359 As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated. 360 360 ... ... @@ -379,11 +379,11 @@ 379 379 380 380 In this section: 381 381 382 -* Enable – a flag to enable the protection; 383 -* Number of cells – a number of cells connected to the BMS; 384 -* Delay before setting the error, millisecond; 385 -* Delay before clearing the error, second; 386 -* Lock – a flag to block the error until the device is restarted. 382 +* **Enable** – a flag to enable the protection; 383 +* **Number of cells** – a number of cells connected to the BMS; 384 +* **Delay before setting the error**, millisecond; 385 +* **Delay before clearing the error**, second; 386 +* **Lock **– a flag to block the error until the device is restarted. 387 387 388 388 As a result of the operation of the protection from the mismatch of the number of cells, the "Cell count error" is generated. 389 389 ... ... @@ -408,11 +408,11 @@ 408 408 409 409 In this section: 410 410 411 -* Enable – a flag to enable the protection; 412 -* Number of cells – a number of temperature sensors connected to the BMS; 413 -* Delay before setting the error, millisecond; 414 -* Delay before clearing the error, second; 415 -* Lock – a flag to block the error until the device is restarted. 411 +* **Enable **– a flag to enable the protection; 412 +* **Number of cells** – a number of temperature sensors connected to the BMS; 413 +* **Delay before setting the error**, millisecond; 414 +* **Delay before clearing the error**, second; 415 +* **Lock **– a flag to block the error until the device is restarted. 416 416 417 417 As a result of the operation of the protection from the mismatch of the number of cells, the "T-sensor count error" is generated. 418 418 ... ... @@ -437,12 +437,12 @@ 437 437 438 438 In this section: 439 439 440 -* Enable – a flag to enable the protection; 441 -* Logic count – a number of BMS Logic devices connected to the BMS Main; 442 -* Scan fast – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 443 -* Delay before setting the error – a delay before setting the error //during initialization//, millisecond; 444 -* Delay before clearing the error– a delay before clearing the error //during initialization//, second; 445 -* Lock – lock the error until the device is reset. 440 +* **Enable **– a flag to enable the protection; 441 +* **Logic count** – a number of BMS Logic devices connected to the BMS Main; 442 +* **Scan fast** – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 443 +* **Delay before setting the error** – a delay before setting the error //during initialization//, millisecond; 444 +* **Delay before clearing the error **– a delay before clearing the error //during initialization//, second; 445 +* **Lock** – lock the error until the device is reset. 446 446 447 447 As a result of the operation of the protection from the mismatch of the number of BMS Logic devices, the "Logic count error" is generated. 448 448 ... ... @@ -471,12 +471,12 @@ 471 471 472 472 In this section: 473 473 474 -* Level 1, 2, 3 – three protection levels. The following parameters are configured at each level: 475 -** Enable – a flag to enable the protection; 476 -** Maximum current, A; 477 -** Delay before setting the error, second; 478 -* Delay before clearing the error, second; 479 -* Lock – a flag to block the error until the device is restarted. 474 +* **Level 1, 2, 3** – three protection levels. The following parameters are configured at each level: 475 +** **Enable **– a flag to enable the protection; 476 +** **Maximum current**, A; 477 +** **Delay before setting the error**, second; 478 +* **Delay before clearing the error**, second; 479 +* **Lock **– a flag to block the error until the device is restarted. 480 480 481 481 If there is a short circuit, the "Short circuit" error is generated. 482 482 ... ... @@ -498,13 +498,13 @@ 498 498 499 499 In this section: 500 500 501 -* Enable – a flag to enable the protection; 502 -* Thermistor – a selection of which cell thermistor will be used as contactor temperature sensor; 503 -* Maximum contactor temperature, °C; 504 -* Tolerant contactor temperature, °C; 505 -* Delay before setting the error, second; 506 -* Delay before clearing the error, second; 507 -* Lock – a flag to block the error until the device is restarted. 501 +* **Enable** – a flag to enable the protection; 502 +* **Thermistor **– a selection of which cell thermistor will be used as contactor temperature sensor; 503 +* **Maximum contactor temperature**, °C; 504 +* **Tolerant contactor temperature**, °C; 505 +* **Delay before setting the error**, second; 506 +* **Delay before clearing the error**, second; 507 +* **Lock **– a flag to block the error until the device is restarted. 508 508 509 509 If there is a contactor overheat, the "High contactor temperature" error is generated. 510 510