Changes for page 3.4 Protections
Last modified by Admin on 2026/04/01 08:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,12 +92,12 @@ 92 92 In this section: 93 93 94 94 * **Enable **– a flag to enable the protection; 95 -* Minimum cell voltage, V; 96 -* Tolerant cell voltage, V; 97 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 98 -* Delay before setting the error, millisecond; 99 -* Delay before clearing the error, second; 100 -* Lock – a flag to block the error until the device is restarted. 95 +* **Minimum cell voltage**, V; 96 +* **Tolerant cell voltage**, V; 97 +* **Check the open circuit voltage instead of the actual voltage** – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 98 +* **Delay before setting the error**, millisecond; 99 +* **Delay before clearing the error**, second; 100 +* **Lock **– a flag to block the error until the device is restarted. 101 101 102 102 As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated. 103 103 ... ... @@ -119,13 +119,13 @@ 119 119 120 120 In this section: 121 121 122 -* Enable – a flag to enable the protection; 123 -* Maximum cell voltage, V; 124 -* Tolerant cell voltage, V; 125 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 126 -* Delay before setting the error, millisecond; 127 -* Delay before clearing the error, second; 128 -* Lock – a flag to block the error until the device is restarted. 122 +* **Enable **– a flag to enable the protection; 123 +* **Maximum cell voltage**, V; 124 +* **Tolerant cell voltage**, V; 125 +* **Check the open circuit voltage instead of the actual voltage** – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 126 +* **Delay before setting the error**, millisecond; 127 +* **Delay before clearing the error**, second; 128 +* **Lock **– a flag to block the error until the device is restarted. 129 129 130 130 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 131 131 ... ... @@ -145,12 +145,12 @@ 145 145 146 146 [[image:1760437465709-702.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]In this section: 147 147 148 -* Enable – a flag to enable the protection; 149 -* Maximum cell imbalance, V; 150 -* Tolerant cell imbalance, V; 151 -* Delay before setting the error, millisecond; 152 -* Delay before clearing the error, second; 153 -* Lock – a flag to block the error until the device is restarted. 148 +* **Enable **– a flag to enable the protection; 149 +* **Maximum cell imbalance**, V; 150 +* **Tolerant cell imbalance**, V; 151 +* **Delay before setting the error**, millisecond; 152 +* **Delay before clearing the error**, second; 153 +* **Lock **– a flag to block the error until the device is restarted. 154 154 155 155 As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 156 156 ... ... @@ -172,14 +172,14 @@ 172 172 173 173 In this section: 174 174 175 -* Enable – a flag to enable the protection; 176 -* Minimum charge temperature, °C; 177 -* Tolerant charge temperature, °C; 178 -* Minimum discharge temperature, °C; 179 -* Tolerant discharge temperature, °C; 180 -* Delay before setting the error, millisecond; 181 -* Delay before clearing the error, second; 182 -* Lock – a flag to block the error until the device is restarted. 175 +* **Enable **– a flag to enable the protection; 176 +* **Minimum charge temperature**, °C; 177 +* **Tolerant charge temperature**, °C; 178 +* **Minimum discharge temperature**, °C; 179 +* **Tolerant discharge temperature**, °C; 180 +* **Delay before setting the error**, millisecond; 181 +* **Delay before clearing the error**, second; 182 +* **Lock **– a flag to block the error until the device is restarted. 183 183 184 184 As a result of the operation of the battery protection from low temperature, the "Low temperature (CH)" and/or “Low temperature (DCH)” error are generated. 185 185 ... ... @@ -201,14 +201,14 @@ 201 201 202 202 In this section: 203 203 204 -* Enable – a flag to enable the protection; 205 -* Maximum charge temperature, °C; 206 -* Tolerant charge temperature, °C; 207 -* Maximum discharge temperature, °C; 208 -* Tolerant discharge temperature, °C; 209 -* Delay before setting the error, millisecond; 210 -* Delay before clearing the error, second; 211 -* Lock – a flag to block the error until the device is restarted. 204 +* **Enable **– a flag to enable the protection; 205 +* **Maximum charge temperature**, °C; 206 +* **Tolerant charge temperature**, °C; 207 +* **Maximum discharge temperature**, °C; 208 +* **Tolerant discharge temperature**, °C; 209 +* **Delay before setting the error**, millisecond; 210 +* **Delay before clearing the error**, second; 211 +* **Lock **– a flag to block the error until the device is restarted. 212 212 213 213 As a result of the operation of the battery protection from high temperature, the "High temperature (CH)" or “High temperature (DCH)” error is generated. 214 214 ... ... @@ -228,10 +228,10 @@ 228 228 229 229 In this section: 230 230 231 -* Enable – a flag to enable the protection; 232 -* Delay before setting the error, millisecond; 233 -* Delay before clearing the error, second; 234 -* Lock – a flag toblockthe error until the device is restarted.231 +* **Enable** – a flag to enable the protection; 232 +* **Delay before setting the error**, millisecond; 233 +* **Delay before clearing the error**, second; 234 +* **Lock **–Lock . 235 235 236 236 As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 237 237 ... ... @@ -258,12 +258,12 @@ 258 258 259 259 In this section: 260 260 261 -* Enable – a flag to enable the detection; 262 -* Maximum humidity, RH%; 263 -* Tolerant humidity, RH%; 264 -* Delay before setting the error, second; 265 -* Delay before clearing the error, second; 266 -* Lock the error until the device is reset. 261 +* **Enable **– a flag to enable the detection; 262 +* **Maximum humidity**, RH%; 263 +* **Tolerant humidity**, RH%; 264 +* **Delay before setting the error**, second; 265 +* **Delay before clearing the error**, second; 266 +* **Lock **– lock the error until the device is reset. 267 267 268 268 As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 269 269