Changes for page 3.4 Protections
Last modified by Admin on 2026/04/01 08:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,14 +22,14 @@ 22 22 23 23 In this section: 24 24 25 -* **Enable**– a flag to enable the protection;26 -* **Maximum charging current**, А;27 -* **Tolerant charging current**, А;28 -* **Maximum discharging current**, А;29 -* **Tolerant discharging current**, А;30 -* **Delay before setting the error**, millisecond;31 -* **Delay before clearing the error**, second;32 -* **Lock**– a flag to block the error until the device is restarted.25 +* Enable – a flag to enable the protection; 26 +* Maximum charging current, А; 27 +* Tolerant charging current, А; 28 +* Maximum discharging current, А; 29 +* Tolerant discharging current, А; 30 +* Delay before setting the error, millisecond; 31 +* Delay before clearing the error, second; 32 +* Lock – a flag to block the error until the device is restarted. 33 33 34 34 As a result of operation of the overcurrent protection, the "Overcurrent" error is generated. 35 35 ... ... @@ -53,13 +53,13 @@ 53 53 54 54 [[image:1735225207687-430.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]]In this section: 55 55 56 -* **Enable**– a flag to enable the protection;57 -* **Threshold to switch from Region 1 to Region 2**– a current value at which current excess calculation will be switched from absolute to relative difference, A;58 -* **Region 1: Current difference**– a value of maximum absolute current difference, A;59 -* **Region 2: Current difference**– a value of maximum relative current excess, A;60 -* **Delay before setting the error**, millisecond;61 -* **Delay before clearing the error**, second;62 -* **Lock**– a flag to block the error until the device is restarted.56 +* Enable – a flag to enable the protection; 57 +* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 58 +* Region 1: Current difference – a value of maximum absolute current difference, A; 59 +* Region 2: Current difference – a value of maximum relative current excess, A; 60 +* Delay before setting the error, millisecond; 61 +* Delay before clearing the error, second; 62 +* Lock – a flag to block the error until the device is restarted. 63 63 64 64 === Discharge current limit === 65 65 ... ... @@ -73,13 +73,13 @@ 73 73 74 74 In this section: 75 75 76 -* **Enable**– a flag to enable the protection;77 -* **Threshold to switch from Region 1 to Region 2**– a current value at which current excess calculation will be switched from absolute to relative difference, A;78 -* **Region 1: Current difference**– a value of maximum absolute current difference, A;79 -* **Region 2: Current difference**– a value of maximum relative current excess, A;80 -* **Delay before setting the error**, millisecond;81 -* **Delay before clearing the error**, second;82 -* **Lock**– a flag to block the error until the device is restarted.76 +* Enable – a flag to enable the protection; 77 +* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 78 +* Region 1: Current difference – a value of maximum absolute current difference, A; 79 +* Region 2: Current difference – a value of maximum relative current excess, A; 80 +* Delay before setting the error, millisecond; 81 +* Delay before clearing the error, second; 82 +* Lock – a flag to block the error until the device is restarted. 83 83 84 84 === Undervoltage === 85 85 ... ... @@ -91,7 +91,7 @@ 91 91 92 92 In this section: 93 93 94 -* **Enable**– a flag to enable the protection;94 +* Enable – a flag to enable the protection; 95 95 * Minimum cell voltage, V; 96 96 * Tolerant cell voltage, V; 97 97 * Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;