Changes for page 3.4 Protections
Last modified by Admin on 2026/04/01 08:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,14 +22,14 @@ 22 22 23 23 In this section: 24 24 25 -* Enable – a flag to enable the protection; 26 -* Maximum charging current, А; 27 -* Tolerant charging current, А; 28 -* Maximum discharging current, А; 29 -* Tolerant discharging current, А; 30 -* Delay before setting the error, millisecond; 31 -* Delay before clearing the error, second; 32 -* Lock – a flag to block the error until the device is restarted. 25 +* **Enable **– a flag to enable the protection; 26 +* **Maximum charging current**, А; 27 +* **Tolerant charging current**, А; 28 +* **Maximum discharging current**, А; 29 +* **Tolerant discharging current**, А; 30 +* **Delay before setting the error**, millisecond; 31 +* **Delay before clearing the error**, second; 32 +* **Lock **– a flag to block the error until the device is restarted. 33 33 34 34 As a result of operation of the overcurrent protection, the "Overcurrent" error is generated. 35 35 ... ... @@ -53,13 +53,13 @@ 53 53 54 54 [[image:1735225207687-430.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]]In this section: 55 55 56 -* Enable – a flag to enable the protection; 57 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 58 -* Region 1: Current difference – a value of maximum absolute current difference, A; 59 -* Region 2: Current difference – a value of maximum relative current excess, A; 60 -* Delay before setting the error, millisecond; 61 -* Delay before clearing the error, second; 62 -* Lock – a flag to block the error until the device is restarted. 56 +* **Enable **– a flag to enable the protection; 57 +* **Threshold to switch from Region 1 to Region 2** – a current value at which current excess calculation will be switched from absolute to relative difference, A; 58 +* **Region 1: Current difference** – a value of maximum absolute current difference, A; 59 +* **Region 2: Current difference** – a value of maximum relative current excess, A; 60 +* **Delay before setting the error**, millisecond; 61 +* **Delay before clearing the error**, second; 62 +* **Lock **– a flag to block the error until the device is restarted. 63 63 64 64 === Discharge current limit === 65 65 ... ... @@ -73,13 +73,13 @@ 73 73 74 74 In this section: 75 75 76 -* Enable – a flag to enable the protection; 77 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A; 78 -* Region 1: Current difference – a value of maximum absolute current difference, A; 79 -* Region 2: Current difference – a value of maximum relative current excess, A; 80 -* Delay before setting the error, millisecond; 81 -* Delay before clearing the error, second; 82 -* Lock – a flag to block the error until the device is restarted. 76 +* **Enable **– a flag to enable the protection; 77 +* **Threshold to switch from Region 1 to Region 2** – a current value at which current excess calculation will be switched from absolute to relative difference, A; 78 +* **Region 1: Current difference** – a value of maximum absolute current difference, A; 79 +* **Region 2: Current difference** – a value of maximum relative current excess, A; 80 +* **Delay before setting the error**, millisecond; 81 +* **Delay before clearing the error**, second; 82 +* **Lock **– a flag to block the error until the device is restarted. 83 83 84 84 === Undervoltage === 85 85 ... ... @@ -91,13 +91,13 @@ 91 91 92 92 In this section: 93 93 94 -* Enable – a flag to enable the protection; 95 -* Minimum cell voltage, V; 96 -* Tolerant cell voltage, V; 97 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 98 -* Delay before setting the error, millisecond; 99 -* Delay before clearing the error, second; 100 -* Lock – a flag to block the error until the device is restarted. 94 +* **Enable **– a flag to enable the protection; 95 +* **Minimum cell voltage**, V; 96 +* **Tolerant cell voltage**, V; 97 +* **Check the open circuit voltage instead of the actual voltage** – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 98 +* **Delay before setting the error**, millisecond; 99 +* **Delay before clearing the error**, second; 100 +* **Lock **– a flag to block the error until the device is restarted. 101 101 102 102 As a result of the operation of battery protection from low voltage, the "Undervoltage" error is generated. 103 103 ... ... @@ -119,13 +119,13 @@ 119 119 120 120 In this section: 121 121 122 -* Enable – a flag to enable the protection; 123 -* Maximum cell voltage, V; 124 -* Tolerant cell voltage, V; 125 -* Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 126 -* Delay before setting the error, millisecond; 127 -* Delay before clearing the error, second; 128 -* Lock – a flag to block the error until the device is restarted. 122 +* **Enable **– a flag to enable the protection; 123 +* **Maximum cell voltage**, V; 124 +* **Tolerant cell voltage**, V; 125 +* **Check the open circuit voltage instead of the actual voltage** – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage; 126 +* **Delay before setting the error**, millisecond; 127 +* **Delay before clearing the error**, second; 128 +* **Lock **– a flag to block the error until the device is restarted. 129 129 130 130 As a result of the operation of the battery protection from high voltage, the "Overvoltage" error is generated. 131 131 ... ... @@ -145,12 +145,12 @@ 145 145 146 146 [[image:1760437465709-702.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]In this section: 147 147 148 -* Enable – a flag to enable the protection; 149 -* Maximum cell imbalance, V; 150 -* Tolerant cell imbalance, V; 151 -* Delay before setting the error, millisecond; 152 -* Delay before clearing the error, second; 153 -* Lock – a flag to block the error until the device is restarted. 148 +* **Enable **– a flag to enable the protection; 149 +* **Maximum cell imbalance**, V; 150 +* **Tolerant cell imbalance**, V; 151 +* **Delay before setting the error**, millisecond; 152 +* **Delay before clearing the error**, second; 153 +* **Lock **– a flag to block the error until the device is restarted. 154 154 155 155 As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 156 156 ... ... @@ -172,14 +172,14 @@ 172 172 173 173 In this section: 174 174 175 -* Enable – a flag to enable the protection; 176 -* Minimum charge temperature, °C; 177 -* Tolerant charge temperature, °C; 178 -* Minimum discharge temperature, °C; 179 -* Tolerant discharge temperature, °C; 180 -* Delay before setting the error, millisecond; 181 -* Delay before clearing the error, second; 182 -* Lock – a flag to block the error until the device is restarted. 175 +* **Enable **– a flag to enable the protection; 176 +* **Minimum charge temperature**, °C; 177 +* **Tolerant charge temperature**, °C; 178 +* **Minimum discharge temperature**, °C; 179 +* **Tolerant discharge temperature**, °C; 180 +* **Delay before setting the error**, millisecond; 181 +* **Delay before clearing the error**, second; 182 +* **Lock **– a flag to block the error until the device is restarted. 183 183 184 184 As a result of the operation of the battery protection from low temperature, the "Low temperature (CH)" and/or “Low temperature (DCH)” error are generated. 185 185 ... ... @@ -201,14 +201,14 @@ 201 201 202 202 In this section: 203 203 204 -* Enable – a flag to enable the protection; 205 -* Maximum charge temperature, °C; 206 -* Tolerant charge temperature, °C; 207 -* Maximum discharge temperature, °C; 208 -* Tolerant discharge temperature, °C; 209 -* Delay before setting the error, millisecond; 210 -* Delay before clearing the error, second; 211 -* Lock – a flag to block the error until the device is restarted. 204 +* **Enable **– a flag to enable the protection; 205 +* **Maximum charge temperature**, °C; 206 +* **Tolerant charge temperature**, °C; 207 +* **Maximum discharge temperature**, °C; 208 +* **Tolerant discharge temperature**, °C; 209 +* **Delay before setting the error**, millisecond; 210 +* **Delay before clearing the error**, second; 211 +* **Lock **– a flag to block the error until the device is restarted. 212 212 213 213 As a result of the operation of the battery protection from high temperature, the "High temperature (CH)" or “High temperature (DCH)” error is generated. 214 214 ... ... @@ -228,10 +228,10 @@ 228 228 229 229 In this section: 230 230 231 -* Enable – a flag to enable the protection; 232 -* Delay before setting the error, millisecond; 233 -* Delay before clearing the error, second; 234 -* Lock – a flag to block the error until the device is restarted. 231 +* **Enable** – a flag to enable the protection; 232 +* **Delay before setting the error**, millisecond; 233 +* **Delay before clearing the error**, second; 234 +* **Lock **– a flag to block the error until the device is restarted. 235 235 236 236 As a result of the operation of the protection against opening the battery cover, the “Battery cover error” is generated. 237 237 ... ... @@ -258,12 +258,12 @@ 258 258 259 259 In this section: 260 260 261 -* Enable – a flag to enable the detection; 262 -* Maximum humidity, RH%; 263 -* Tolerant humidity, RH%; 264 -* Delay before setting the error, second; 265 -* Delay before clearing the error, second; 266 -* Lock the error until the device is res et.261 +* **Enable **– a flag to enable the detection; 262 +* **Maximum humidity**, RH%; 263 +* **Tolerant humidity**, RH%; 264 +* **Delay before setting the error**, second; 265 +* **Delay before clearing the error**, second; 266 +* **Lock **– a flag to block the error until the device is restarted. 267 267 268 268 As a result of the operation of the battery protection from high humidity, the "High humidity" error is generated. 269 269 ... ... @@ -290,12 +290,12 @@ 290 290 291 291 In this section: 292 292 293 -* Enable – a flag to enable the protection;294 -* Maximum humidity, RH%; 295 -* Tolerant humidity, RH%; 296 -* Delay before setting the error, second; 297 -* Delay before clearing the error, second; 298 -* Lock – lock the error until the device is reset. 293 +* **Enable **– a flag to enable the protection; 294 +* **Maximum humidity**, RH%; 295 +* **Tolerant humidity**, RH%; 296 +* **Delay before setting the error**, second; 297 +* **Delay before clearing the error**, second; 298 +* **Lock **– lock the error until the device is reset. 299 299 300 300 As a result of the operation of the battery protection from water, the "Water" error is generated. 301 301 ... ... @@ -320,12 +320,12 @@ 320 320 321 321 In this section: 322 322 323 -* Enable – a flag to enable the protection; 324 -* Maximum temperature, °C; 325 -* Tolerant temperature, °C; 326 -* Delay before setting the error, second; 327 -* Delay before clearing the error, second; 328 -* Lock – lock the error until the device is reset. 323 +* **Enable **– a flag to enable the protection; 324 +* **Maximum temperature**, °C; 325 +* **Tolerant temperature**, °C; 326 +* **Delay before setting the error**, second; 327 +* **Delay before clearing the error**, second; 328 +* **Lock **– lock the error until the device is reset. 329 329 330 330 As a result of the operation of the protection from high temperatures of BMS Logic devices, the "High Logic temperature" is generated. 331 331 ... ... @@ -351,10 +351,10 @@ 351 351 352 352 In this section: 353 353 354 -* Enable – a flag to enable the protection; 355 -* Delay before setting the error, second; 356 -* Delay before clearing the error, second; 357 -* Lock – lock the error until the device is reset. 354 +* **Enable **– a flag to enable the protection; 355 +* **Delay before setting the error**, second; 356 +* **Delay before clearing the error**, second; 357 +* **Lock **– lock the error until the device is reset. 358 358 359 359 As a result of the protection from loss of communication with BMS Logic devices, the "Logic offline" error is generated. 360 360 ... ... @@ -379,11 +379,11 @@ 379 379 380 380 In this section: 381 381 382 -* Enable – a flag to enable the protection; 383 -* Number of cells – a number of cells connected to the BMS; 384 -* Delay before setting the error, millisecond; 385 -* Delay before clearing the error, second; 386 -* Lock – a flag to block the error until the device is restarted. 382 +* **Enable** – a flag to enable the protection; 383 +* **Number of cells** – a number of cells connected to the BMS; 384 +* **Delay before setting the error**, millisecond; 385 +* **Delay before clearing the error**, second; 386 +* **Lock **– a flag to block the error until the device is restarted. 387 387 388 388 As a result of the operation of the protection from the mismatch of the number of cells, the "Cell count error" is generated. 389 389 ... ... @@ -408,7 +408,7 @@ 408 408 409 409 In this section: 410 410 411 -* Enable – a flag to enable the protection; 411 +* **Enable **– a flag to enable the protection; 412 412 * Number of cells – a number of temperature sensors connected to the BMS; 413 413 * Delay before setting the error, millisecond; 414 414 * Delay before clearing the error, second;