Changes for page 3.4 Protections

Last modified by Admin on 2026/04/01 08:42

From version 51.1
edited by Admin
on 2026/03/31 14:44
Change comment: There is no comment for this version
To version 51.2
edited by Admin
on 2026/04/01 08:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,14 +22,14 @@
22 22  
23 23  In this section:
24 24  
25 -* Enable – a flag to enable the protection;
26 -* Maximum charging current, А;
27 -* Tolerant charging current, А;
28 -* Maximum discharging current, А;
29 -* Tolerant discharging current, А;
30 -* Delay before setting the error, millisecond;
31 -* Delay before clearing the error, second;
32 -* Lock – a flag to block the error until the device is restarted.
25 +* **Enable **– a flag to enable the protection;
26 +* **Maximum charging current**, А;
27 +* **Tolerant charging current**, А;
28 +* **Maximum discharging current**, А;
29 +* **Tolerant discharging current**, А;
30 +* **Delay before setting the error**, millisecond;
31 +* **Delay before clearing the error**, second;
32 +* **Lock **– a flag to block the error until the device is restarted.
33 33  
34 34  As a result of operation of the overcurrent protection, the "Overcurrent" error is generated.
35 35  
... ... @@ -53,13 +53,13 @@
53 53  
54 54  [[image:1735225207687-430.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]]In this section:
55 55  
56 -* Enable – a flag to enable the protection;
57 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A;
58 -* Region 1: Current difference – a value of maximum absolute current difference, A;
59 -* Region 2: Current difference – a value of maximum relative current excess, A;
60 -* Delay before setting the error, millisecond;
61 -* Delay before clearing the error, second;
62 -* Lock – a flag to block the error until the device is restarted.
56 +* **Enable **– a flag to enable the protection;
57 +* **Threshold to switch from Region 1 to Region 2** – a current value at which current excess calculation will be switched from absolute to relative difference, A;
58 +* **Region 1: Current difference** – a value of maximum absolute current difference, A;
59 +* **Region 2: Current difference** – a value of maximum relative current excess, A;
60 +* **Delay before setting the error**, millisecond;
61 +* **Delay before clearing the error**, second;
62 +* **Lock **– a flag to block the error until the device is restarted.
63 63  
64 64  === Discharge current limit ===
65 65  
... ... @@ -73,13 +73,13 @@
73 73  
74 74  In this section:
75 75  
76 -* Enable – a flag to enable the protection;
77 -* Threshold to switch from Region 1 to Region 2 – a current value at which current excess calculation will be switched from absolute to relative difference, A;
78 -* Region 1: Current difference – a value of maximum absolute current difference, A;
79 -* Region 2: Current difference – a value of maximum relative current excess, A;
80 -* Delay before setting the error, millisecond;
81 -* Delay before clearing the error, second;
82 -* Lock – a flag to block the error until the device is restarted.
76 +* **Enable **– a flag to enable the protection;
77 +* **Threshold to switch from Region 1 to Region 2** – a current value at which current excess calculation will be switched from absolute to relative difference, A;
78 +* **Region 1: Current difference** – a value of maximum absolute current difference, A;
79 +* **Region 2: Current difference** – a value of maximum relative current excess, A;
80 +* **Delay before setting the error**, millisecond;
81 +* **Delay before clearing the error**, second;
82 +* **Lock **– a flag to block the error until the device is restarted.
83 83  
84 84  === Undervoltage ===
85 85  
... ... @@ -91,7 +91,7 @@
91 91  
92 92  In this section:
93 93  
94 -* Enable – a flag to enable the protection;
94 +* **Enable **– a flag to enable the protection;
95 95  * Minimum cell voltage, V;
96 96  * Tolerant cell voltage, V;
97 97  * Check the open circuit voltage instead of the actual voltage – a flag to use the U,,ocv,, (corrected due to current and cell resistance) cell voltage;