... ... @@ -42,6 +42,14 @@ 42 42 If there is the "Overcurrent" error, the **charging **and **discharging **contactors open. 43 43 ))) 44 44 45 +=== Charge current limit === 46 + 47 +TBA 48 + 49 +=== Discharge current limit === 50 + 51 +TBA 52 + 45 45 === Undervoltage === 46 46 47 47 The BMS Main 3 device implements battery protection from too low voltage on the cells. ... ... @@ -269,7 +269,7 @@ 269 269 If there is the “Water” error, the **“Critical error”** is generated and **all relays open**. 270 270 ))) 271 271 272 -=== HighLogic temperature ===280 +=== Logic high temperature === 273 273 274 274 To change the overheating protection parameters of BMS Logic devices, select the "Protections → High Logic temperature" section: 275 275 ... ... @@ -503,6 +503,10 @@ 503 503 If there is the "Power switch error", the **“Critical error” **is generated and **all relays open.** 504 504 ))) 505 505 514 +=== Power fault === 515 + 516 +TBA 517 + 506 506 === Charge contactor cycles === 507 507 508 508 The BMS Main 3 device protects the charging contactor against frequent switching. ... ... @@ -692,28 +692,6 @@ 692 692 If there is the “Contactor feedback” error, the **“Critical error” **is generated and **all relays open.** 693 693 ))) 694 694 695 -=== Precharge === 696 - 697 -BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. To change the pre-charge monitoring parameters, select the "Protections → Precharge" section: 698 - 699 -[[image:1733328487097-648.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="99" width="800"]] 700 - 701 -In this section: 702 - 703 -* Enable – a flag to enable the protection; 704 -* Delay before setting the error, millisecond; 705 -* Delay before clearing the error, second; 706 -* Lock – a flag to block the error until the device is restarted. 707 - 708 -As a result of the protection algorithms the “Precharge error” is generated. Error generation conditions: 709 - 710 -* precharging process cannot be finished (the precharge current does not decrease or voltages before and after contactors are not equal) during the “Delay before setting the error” time. 711 - 712 -(% class="box infomessage" %) 713 -((( 714 -If there is the “Precharge error”, **charging **and **discharging **contactors open. 715 -))) 716 - 717 717 === Insulation === 718 718 719 719 The BMS Main 3 device can detect a physical signal or CAN bus message from an external insulation monitoring device (such as Bender IR155, iso165C, BMD IMD) to monitor the insulation quality. ... ... @@ -805,7 +805,7 @@ 805 805 If there is the “Critical error”, **all **contactors open. 806 806 ))) 807 807 808 -=== General error ===798 +=== General error === 809 809 810 810 To change the general error parameters, select the "Protections → Critical error" section: 811 811
- 1735224224155-829.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content