... ... @@ -152,15 +152,15 @@ 152 152 * Delay before clearing the error, second; 153 153 * Lock – a flag to block the error until the device is restarted. 154 154 155 -As a result of the operation of the battery protection from cell imbalance, the "Cell im balance” errorisgenerated.155 +As a result of the operation of the battery protection from cell imbalance, the "Cell im” error are generated. 156 156 157 157 Error generation conditions: 158 158 159 -* the voltage differencebetweenthe mostchargedcellandtheleastchargedcellismorethan the “Maximum cellimbalance” value for the “Delay before setting the error” time.159 +* the minimum temperature among all cells of the battery is less than the “Minimum charging (discharging) temperature” value for the “Delay before setting the error” time. 160 160 161 161 Conditions for removing the error: 162 162 163 -* the voltage differencebetweenthe mostchargedcellandtheleastchargedcellislessthan the “Tolerant cellimbalance” value for the “Delay before clearing the error” time.163 +* the minimum temperature among all cells of the battery is greater than the “Tolerant charging (discharging) temperature” value for the “Delay before clearing the error” time. 164 164 165 165 === Low temperature === 166 166 ... ... @@ -433,7 +433,7 @@ 433 433 434 434 To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section: 435 435 436 -[[image:17 62425434368-516.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]436 +[[image:1733328415732-163.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]] 437 437 438 438 In this section: 439 439 ... ... @@ -440,8 +440,6 @@ 440 440 * Enable – a flag to enable the protection; 441 441 * Logic count – a number of BMS Logic devices connected to the BMS Main; 442 442 * Scan fast – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 443 -* Delay before setting the error – a delay before setting the error //during initialization//, millisecond; 444 -* Delay before clearing the error– a delay before clearing the error //during initialization//, second; 445 445 * Lock – lock the error until the device is reset. 446 446 447 447 As a result of the operation of the protection from the mismatch of the number of BMS Logic devices, the "Logic count error" is generated. ... ... @@ -448,13 +448,11 @@ 448 448 449 449 Error generation conditions: 450 450 451 -* during the initialization BMS Main 3 have not found required number of BMS Logic devices during the "Delay before setting the error" time; 452 -* after the initialization the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value. 449 +* the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value. 453 453 454 454 Conditions for removing the error: 455 455 456 -* during the initialization BMS Main 3 have found required number of BMS Logic devices and the "Delay before setting the error" time has passed; 457 -* after the initialization the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value. 453 +* the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value. 458 458 459 459 (% class="box warningmessage" %) 460 460 (((
- 1762425390154-843.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.8 KB - Content
- 1762425434368-516.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.8 KB - Content