Changes for page 3.4 Protections
Last modified by Admin on 2025/11/06 10:39
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -139,29 +139,10 @@ 139 139 140 140 === Cell imbalance === 141 141 142 -The BMS Main 3 device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate battery imbalance, then imbalance protection generates an error when imbalance is above estimated threshold.142 +The BMS Main 3 device implements battery protection from too much cell imbalance. If balancing algorithm is not enough to compensate 143 143 144 -To change the battery protection parameters from cellimbalance, select the "Protections →Cellimbalance" section:144 +To change the battery protection parameters from low temperature, select the "Protections → Low temperature" section: 145 145 146 -[[image:1760437465709-702.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="133" width="800"]]In this section: 147 - 148 -* Enable – a flag to enable the protection; 149 -* Maximum cell imbalance, V; 150 -* Tolerant cell imbalance, V; 151 -* Delay before setting the error, millisecond; 152 -* Delay before clearing the error, second; 153 -* Lock – a flag to block the error until the device is restarted. 154 - 155 -As a result of the operation of the battery protection from cell imbalance, the "Cell imbalance” error is generated. 156 - 157 -Error generation conditions: 158 - 159 -* the voltage difference between the most charged cell and the least charged cell is more than the “Maximum cell imbalance” value for the “Delay before setting the error” time. 160 - 161 -Conditions for removing the error: 162 - 163 -* the voltage difference between the most charged cell and the least charged cell is less than the “Tolerant cell imbalance” value for the “Delay before clearing the error” time. 164 - 165 165 === Low temperature === 166 166 167 167 The BMS Main 3 device implements battery protection from too low temperature. ... ... @@ -433,7 +433,7 @@ 433 433 434 434 To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section: 435 435 436 -[[image:17 62425434368-516.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]417 +[[image:1733328415732-163.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]] 437 437 438 438 In this section: 439 439 ... ... @@ -440,8 +440,6 @@ 440 440 * Enable – a flag to enable the protection; 441 441 * Logic count – a number of BMS Logic devices connected to the BMS Main; 442 442 * Scan fast – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time); 443 -* Delay before setting the error – a delay before setting the error //during initialization//, millisecond; 444 -* Delay before clearing the error– a delay before clearing the error //during initialization//, second; 445 445 * Lock – lock the error until the device is reset. 446 446 447 447 As a result of the operation of the protection from the mismatch of the number of BMS Logic devices, the "Logic count error" is generated. ... ... @@ -448,13 +448,11 @@ 448 448 449 449 Error generation conditions: 450 450 451 -* during the initialization BMS Main 3 have not found required number of BMS Logic devices during the "Delay before setting the error" time; 452 -* after the initialization the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value. 430 +* the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value. 453 453 454 454 Conditions for removing the error: 455 455 456 -* during the initialization BMS Main 3 have found required number of BMS Logic devices and the "Delay before setting the error" time has passed; 457 -* after the initialization the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value. 434 +* the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value. 458 458 459 459 (% class="box warningmessage" %) 460 460 (((
- 1760437465709-702.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.4 KB - Content
- 1762425390154-843.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.8 KB - Content
- 1762425434368-516.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.8 KB - Content