... ... @@ -448,11 +448,13 @@
448 448  
449 449  Error generation conditions:
450 450  
451 +* during the initialization BMS Main 3 have not found required number of BMS Logic devices during the "Delay before setting the error" time;
451 451  * after the initialization the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value.
452 452  
453 453  Conditions for removing the error:
454 454  
455 -* the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value.
456 +* during the initialization BMS Main 3 have found required number of BMS Logic devices and the "Delay before setting the error" time has passed;
457 +* after the initialization the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value.
456 456  
457 457  (% class="box warningmessage" %)
458 458  (((
... ... @@ -859,7 +859,7 @@
859 859  
860 860  To change the critical error parameters, select the "Protections → Critical error" section:
861 861  
862 -[[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]]
864 +[[image:1762775547945-129.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="800"]]
863 863  
864 864  In this section:
865 865  
... ... @@ -866,6 +866,7 @@
866 866  * Enable – a flag to enable the protection;
867 867  * Delay before setting the error, millisecond;
868 868  * Delay before clearing the error, second;
871 +* Errors 1, 2 to to ignore when setting the critical error;
869 869  * Lock – a flag to block the error until the device is restarted.
870 870  
871 871  The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
1762775508522-157.png