... ... @@ -433,7 +433,7 @@
433 433  
434 434  To change the protection parameters from the mismatch of the number of BMS Logic devices to the set value, select the "Protections → Logic count” section:
435 435  
436 -[[image:1733328415732-163.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]]
436 +[[image:1762425434368-516.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="125" width="800"]]
437 437  
438 438  In this section:
439 439  
... ... @@ -440,6 +440,8 @@
440 440  * Enable – a flag to enable the protection;
441 441  * Logic count – a number of BMS Logic devices connected to the BMS Main;
442 442  * Scan fast – a flag to scan BMS Logic devices fast (devices with addresses from 1 to “Logic count” are scanned; this mode reduces BMS system startup time);
443 +* Delay before setting the error – a delay before setting the error //during initialization//, millisecond;
444 +* Delay before clearing the error– a delay before clearing the error //during initialization//, second;
443 443  * Lock – lock the error until the device is reset.
444 444  
445 445  As a result of the operation of the protection from the mismatch of the number of BMS Logic devices, the "Logic count error" is generated.
... ... @@ -446,11 +446,13 @@
446 446  
447 447  Error generation conditions:
448 448  
449 -* the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value.
451 +* during the initialization BMS Main 3 have not found required number of BMS Logic devices during the "Delay before setting the error" time;
452 +* after the initialization the number of BMS Logic devices connected to the BMS Main is **not equal** to the “Logic count” value.
450 450  
451 451  Conditions for removing the error:
452 452  
453 -* the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value.
456 +* during the initialization BMS Main 3 have found required number of BMS Logic devices and the "Delay before setting the error" time has passed;
457 +* after the initialization the number of BMS Logic devices connected to the BMS Main is **equal** to the “Logic count” value.
454 454  
455 455  (% class="box warningmessage" %)
456 456  (((
... ... @@ -857,7 +857,7 @@
857 857  
858 858  To change the critical error parameters, select the "Protections → Critical error" section:
859 859  
860 -[[image:1733328487100-898.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="101" width="800"]]
864 +[[image:1762775547945-129.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="800"]]
861 861  
862 862  In this section:
863 863  
... ... @@ -864,6 +864,7 @@
864 864  * Enable – a flag to enable the protection;
865 865  * Delay before setting the error, millisecond;
866 866  * Delay before clearing the error, second;
871 +* Errors 1, 2 to to ignore when setting the critical error;
867 867  * Lock – a flag to block the error until the device is restarted.
868 868  
869 869  The "Critical error" signal is generated if at least one of the critical errors (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]) is generated during the “Delay before setting the error” time.
1762775508522-157.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
1762775547945-129.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +21.4 KB
Content